34
E
RS-232C command table
How to read the command table
Command:
Command field (See page 33.)
Direction:
W When the “Parameter” is set in the parameter field (see page 33), the command functions as described
under “Control/Response Contents”.
R The returned value indicated under “Reply” can be obtained by setting “????”, “
?” or “???+”
(repeater control) in the parameter field. (See page 33.)
Parameter:
Parameter field (See page 33.)
Reply:
Response (Returned value)
* :
When POWER SAVE MODE is set to OFF:
“●/○” : Indicates a command which can be used in standby mode or when the power is on.
“–” : Indicates a command which can be used when the power is on. Cannot be used in standby mode.
When POWER SAVE MODE is set to ON:
“●” : Indicates a command which can be used in standby mode or when the power is on.
“○/–” : Indicates a command which can be used when the power is on. Cannot be used in standby mode.
Power control/Input mode selection
Function
Command Direction
Parameter
Reply
Control/Response contents
*
POWER CONTROL
POWR
W
0
Switches to standby mode.
●
1
Returns from standby mode.
R
0
Standby mode
1
Normal mode
2
Input signal waiting mode
INPUT MODE SELECTION
INPS
W
0
Toggle change for input mode.
-
2
D-SUB
10
HDMI1
11
USB
13
HDMI2
18
HDMI3
PICTURE menu
Function
Command Direction
Parameter
Reply
Control/Response contents
*
BRIGHT
VLMP
WR
0-50
0-50
-
SIZE (Screen size selection)
WIDE
WR
1-4
1-4
1: WIDE, 2: NORMAL, 3: Dot by Dot, 4: ZOOM
COLOR MODE
BMOD
WR
0
0
STD
2
2
VIVID
3
3
sRGB
4
4
HIGH ILLUMINANCE
WHITE BALANCE
WHBL
WR
0-2
0-2
0:THRU, 1:PRESET, 2:USER
R-CONTRAST
CRTR
WR
0-255
0-255
“ERR” when WHBL is not set to 2.
G-CONTRAST
CRTG
WR
0-255
0-255
B-CONTRAST
CRTB
WR
0-255
0-255
SETUP menu
Function
Command Direction
Parameter
Reply
Control/Response contents
*
Telnet User name
USER
WR
XXXXXXXX
XXXXXXXX
8 characters or less; half-width alphanumeric characters, “-”, and “_”.
(The field can be left blank, but spaces cannot be entered.)
-
Telnet Password
PASS
WR
XXXXXXXX
XXXXXXXX
8 characters or less; half-width alphanumeric characters, “-”, and “_”.
(The field can be left blank, but spaces cannot be entered.)
THERMAL SENSOR SETTING
STDR
WR
0-1
0-1
0: LANDSCAPE, 1: PORTRAIT
Model
INF1
R
Value
Serial no.
SRNO
R
Value
AUTO
ASNC
W
1
Adjust CLOCK/PHASE/H-POS/V-POS automatically in D-SUB
ALL RESET
RSET
W
0
Controlling the Monitor with a computer (RS-232C)