RESETING THE TOTAL LAMP TIMER
AC socket
INPUT button
ENTER button
UNDO button
ON button
1
Connect the power cord.
•
Plug the power cord into the AC socket
of the projector.
2
Reset the lamp timer.
•
While pressing simultaneously
,
and
on the projector, press
ON
on the projector.
•
“LAMP 100%” is displayed, indicating
that the lamp timer is reset.
Info
•
Make sure to reset the lamp timer only
when replacing the lamp. If you reset the
lamp timer and continue to use the same
lamp, this may cause the lamp to become
damaged or explode.
■
The warning lights on the projector indicate problems inside the projector.
■
If a problem occurs, either the temperature warning indicator or the lamp indicator will illuminate
red, and the projector will enter the standby mode. After the projector has entered the standby
mode, follow the procedures given below.
Temperature warning
indicator
Lamp indicator
Power indicator
About the temperature warning indicator
If the temperature inside the pro-
jector increases, due to blockage
of the air vents, or the setting lo-
cation, “
” will blink in the
lower left corner of the picture. If
the temperature keeps on rising,
the lamp will turn off and the tem-
perature warning indicator will
blink, the cooling fan will run for
further 90 seconds, then the pro-
jector will enter the standby mode.
After “
” appears, be sure to
perform the following measures.
About the lamp indicator
■
The lamp life becomes 0%, when used
for approximately 3,000 hours with “ON”
in “Power Save” or when used for approxi-
mately 2,000 hours with “OFF” in “Power
Save”
■
When the remaining lamp life becomes
5% or less, “
” will be displayed on the
screen in yellow. When the percentage
becomes 0%, “
” will change to “
”
(red), the lamp will automatically turn off
and then the projector will automatically
enter the standby mode. At this time, the
lamp indicator will illuminate in red.
■
If you try to turn on the projector a fourth
time without replacing the lamp, the pro-
jector will not turn on.
Maintenance indicator
Condition
Problem
Possible Solution
Temperature
warning
indicator
Normal
Abnormal
Off
Red on/
Standby
The internal
temperature is
abnormally high.
Abnormal
• Blocked air intake
• Relocate the projector to an area
with proper ventilation.
• Cooling fan break-
down
• Internal circuit failure
• Clogged air intake
• Take the projector to your nearest
Sharp Authorized Projector Dealer
or Service Center for repair.
Lamp
indicator
Red on/
Standby
The lamp does
not illuminate.
• Burnt-out lamp
• Lamp circuit failure
• Carefully replace the lamp.
• Take the projector to your nearest
Sharp Authorized Projector Dealer
or Service Center for repair .
• Please exercise care when
replacing the lamp.
Green on
Green
blinks
when the
lamp is
warming up
or shutting
down.
Red blinks/
Red on
Time to change
the lamp
• Remaining lamp life
becomes 5% or
under.
Power
indicator
The power
indicator blinks
in red when the
projector is on.
• The filter cover, lamp
unit cover or lens
cover is open.
• Securely install the covers.
• If the power indicator blinks even
when the filter cover is securely
installed, contact your nearest
Sharp Authorized Projector Dealer
or Service Center for advice.
Green on/
Red on
Red blinks
Содержание Notevision XG-C58X
Страница 132: ...158 6 5 4 3 2 1 A B C D E F G H XG C58X XG C68X OUTPUT UNIT Side B AUSGANGS EINHEIT Seite B ...
Страница 138: ...164 6 5 4 3 2 1 A B C D E F G H XG C58X XG C68X POWER UNIT Side A NETZ EINHEIT Seite A ...
Страница 144: ...170 6 5 4 3 2 1 A B C D E F G H XG C58X XG C68X PC I F UNIT Side A PC I F EINHEIT Seite A ...
Страница 145: ...171 6 5 4 3 2 1 A B C D E F G H XG C58X XG C68X PC I F UNIT Side B PC I F EINHEIT Seite B ...
Страница 171: ...197 XG C58X XG C68X PACKING OF THE SET VERPACKEN DES GERÄTS Front ...