NORMAL INSTALLATION STEPS

ANTI-TIP BLOCK INSTALLATION INSTRuCTIONS

To reduce the risk of tipping of the drawer, the Anti-Tip block must be properly installed 

located 14 

13

/

16

-inches above the floor on which the Microwave Drawer will sit. The 

6-inch Anti-Tip block must be provided by the installer. See Figures 1, 4 and 5. The 

Anti-Tip block prevents serious injury that might result from spilled hot liquids.
If the Microwave Drawer is ever moved to a different location, the Anti-Tip block must 

also be moved and installed. When installed to the wall, make sure that the screws 

completely penetrate the dry wall and are secured in wood or metal so that the block 

is totally stable. When fastening, be sure that the screws do not penetrate electrical 

wiring or plumbing.

ANtI-tIP BLoCk

Figure 8

ELECtRICAL oUtLEt

The electrical requirements are a 120 volt 60 Hz, AC only, 15 amp. or more protected 

electrical supply. It is recommended that a separate circuit serving only this appliance 

be provided.
The drawer is equipped with a 3-prong grounding plug. It must be plugged into a wall 

receptacle that is properly installed and grounded. Should you only have a 2-prong 

outlet, have a qualified electrician install a correct wall receptacle.
Note: If you have any questions about the grounding or electrical instructions, consult 

a qualified electrician or service person.

*  Can also be installed using an electrical outlet in an adjacent cabinet within the area where 

the provided electrical cord can reach.

  Always check electrical codes for requirements.

Figure 9

GRoUNdING INStRUCtIoNS

This appliance must be grounded. The Microwave Drawer is equipped with a cord 

having a grounding wire with a grounding plug. It must be plugged into a wall receptacle 

that is properly installed and grounded in accordance with the National Electrical Code 

and local codes and ordinances. In the event of an electrical short circuit, grounding 

reduces risk of electric shock by providing an escape wire for the electric current.

 – Improper use of the grounding plug can result in a risk of electric 

shock. Do not use an extension cord. If the power supply cord is too short, have a 

qualified electrician or serviceman install an outlet near the appliance.

3-Prong plug

Grounding pin

3-Prong receptacle

Grounded receptacle box

Grounding adapter

Grounded receptacle box

Screw

Tab for grounding screw

Содержание Microwave Drawer SMD3070ASY

Страница 1: ...to leave these instructions with the consumer Important notes to the Consumer Keep this manual with your Operation Manual for future reference As when using any microwave oven generating heat there are certain safety precautions you should follow These are listed in the Operation Manual Read all and follow carefully Be sure your Microwave Drawer is installed and grounded properly by a qualified in...

Страница 2: ...d with the Flush Mount Deflector vent 24 Microwave Drawer Measurements B C G D B C D E F G H I I J K L M N O P A Q A F E Figure 1 Figure 2 Cutout Dimension 22 1 8 x 15 9 16 A 6 B Suggested electrical outlet location C Anti Tip block D 5 E 3 1 2 F 4 G 22 1 8 opening H 14 13 16 to bottom of Anti Tip block I Allow 7 8 overlap J 23 1 2 minimum depth K Allow 3 16 overlap L 36 countertop height M Allow ...

Страница 3: ... in custom cabinets with extended counter tops take into account visibility and access to controls See Figure 3 Move oven location downward for extended countertops Extended countertops Figure 3 A 25 B 1 2 minimum C 15 7 8 D 36 E Control panel shown in open position F 24 G 34 1 2 ...

Страница 4: ...J 28 7 16 opening K Allow 3 16 overlap L 14 13 16 to bottom of Anti Tip block M Allow 23 32 overlap N 23 1 2 minimum depth O 15 9 16 opening P Allow 1 8 overlap Q Floor must support 100 lb R 30 cabinet minimum Can also be installed using an electrical outlet in an adjacent cabinet within the area where the provided electrical cord can reach Power cord access hole in cabinet should be a minimum 1 1...

Страница 5: ...16 to bottom of Anti Tip block I Allow 23 32 overlap J 23 1 2 minimum depth K Allow 3 16 overlap L 36 countertop height M Allow 7 16 overlap N Floor must support 100 lb O 30 cabinet minimum P 15 9 16 opening Q Allow 1 8 overlap A 21 5 8 B 4 11 16 C 1 3 4 D 21 7 8 E 29 7 8 F 15 7 8 G 14 19 32 H 1 9 64 door thickness I 15 auto drawer opening J 4 Cutout Dimension 28 7 16 x 15 9 16 ...

Страница 6: ... in custom cabinets with extended counter tops take into account visibility and access to controls See Figure 7 Move oven location downward for extended countertops Extended countertops Figure 7 A 25 B 1 2 minimum C 15 7 8 D 36 E Control panel shown in open position F 24 G 34 1 2 ...

Страница 7: ...wall receptacle that is properly installed and grounded Should you only have a 2 prong outlet have a qualified electrician install a correct wall receptacle Note If you have any questions about the grounding or electrical instructions consult a qualified electrician or service person Can also be installed using an electrical outlet in an adjacent cabinet within the area where the provided electric...

Страница 8: ...serial number Open the Microwave Drawer fully The label is beyond the back wall of the microwave cavity facing up from the flat surface Care cleaning and maintenance Refer to the Operation Manual for cleaning instructions Before you call for service Read the BEFORE YOU CALL and operating instruction sections in your Operation Manual It may save you time and expense The list includes common occurre...

Отзывы: