MD-MS200W/MD-MS200/MD-MS200H
– 13 –
5. TEST-REC Mode
Step No.
Setting Method
Display
Step 1
Test mode STOP state
[ T E S T ]
Step 2
BASS button
Step 3
AUTO menu
[ A U T O ]
Step 4
SKIP UP button x 4times (Or SKIP DOWN button x 6 times)
Step 5
TEST-REC menu
[ T R E C ]
Step 6
When the DISP button is pressed, the process proceeds to (7).
When the PLAY button is pressed, the process proceeds to (9).
Step 7
TEST-REC mode
[ A d 0 0 5 0 ]
Step 8
PLAY button
Step 9
Continuous playback mode (groove)
[ A P ]
Step 10
STOP button
Step 11
Test mode STOP state
[ T E S T ]
• When the STOP button is pressed while the TEST-REC menu appears, or in the TEST-REC mode or continuous record mode, the mode
changes to the TEST mode stop state.
• When the PLAY button is pressed while the TEST-REC menu appears, the continuous record is initiated from the current pickup position.
• Whenever the DISP button is pressed in the TEST-REC mode, the address changes as follows.
0050 — 03C0 — 0700 — 08A0 — 0050 —
• Whenever the BASS button is pressed in the TEST-REC mode, the digit which is changed by the SKIP UP/DOWN button changes as
follows.
0050 — 0050 — 0050 — 0050 — 0050 —
• When the SKIP UP button s pressed in the TEST-REC mode, the digit of address specified by the BASS button is set to +1h.(0 to F)
• When the SKIP DOWN button is pressed in the TEST-REC mode, the digit of address specified by the BASS button is set to -1h. (0 to F)
* When the SKIP UP/DOWN button is held down, the setting changes continuously, one cycle being 100 ms.
• When the VOL UP/DOWN button is pressed in the TEST-REC mode or continuous record mode, the laser record power changes.
(Servo gain changes also according to record power.)
* After the laser record power is indicated for one second, the address indication is restored.
[ R P W ]
• : Address
• : Laser power cord
• Operation is disabled if the premastered disc or disc is in miserase-protected state.
6. INNER Mode
Step No.
Step 1
Test mode STOP state
[ T E S T ]
Step 2
BASS button
Step 3
AUTO menu
[ A U T O ]
Step 4
SKIP UP button x 5 times
(Or SKIP DOWN button x 5 times)
Step 5
INNER menu
[ I N N E R ]
Setting Method
Display
Step No.
Step 6
PLAY button
Step 7
INNER switch position measurement
[ S Q ]
Step 8
STOP button
Step 9
Test mode STOP state
[ T E S T ]
Setting Method
Display
• When the STOP button is pressed while the INNER menu appears, the mode changes to TEST mode stop state.
•
: Address