![Sharp LC-32LE210 Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/sharp/lc-32le210/lc-32le210_service-manual_1253632016.webp)
16
LC-32LE210
LC-32LE220
SERVICE ADJUSTMENTS
1. Adjustment method after PWB and/or IC replacement due to repair
The unit is set to the optimum performance at the time of shipment from the factory.
If any value should become improper or any adjustment is necessary due to the part replacement, make an adjust-
ment
according
to
the
following
procedure.
1.1. Procure the following units in order to replace the main unit:
MAIN
UNIT
DUNTKF639FMxx
NOTE: [Caution when replacing ICs in the main unit (IC1901, IC1902, IC1902, IC1501, IC1006 and IC1007)]
Before replacing the relevant part, procure the following parts in which the data have been rewritten.
Ref.
Description
Parts code IC + data
Description new IC code for service
IC1901
HDMI EDID 1
RH-IXD236WJZZY
RH-IXD080WJZZY AND DATA LC32LE2x0E_HDMI_1_EDID
IC1902
HDMI EDID 2
RH-IXD237WJZZY
RH-IXD080WJZZY AND DATA LC32LE2x0E_HDMI_2_EDID
IC1903
HDMI EDID 3
RH-IXD238WJZZY
RH-IXD080WJZZY AND DATA LC32LE2x0E_HDMI_3_EDID
IC1501
PC EDID
RH-IXD239WJZZY
RH-IXD080WJZZY AND DATA LC32LE2x0E_PC_EDID
IC1006
HDCP USER SETTINGS
RH-IXD261WJZZY
RH-IXC986WJZZY AND DATA LC32LE2x0E_HDCP_KEY
IC1007
*
FLASH
MEMORY
RH-IXD262WJZZY
RH-IXD012WJZZY and LE210_v1.25_PANEL_AUO_BOARD_N1
RH-IXD263WJZZY
RH-IXD012WJZZY and LE210B_v1.25_PANEL_CMI_BOARD_N1
2. Entering and exiting the adjustment process mode. Standard method.
1. By key-unit.
1. Unplug the AC power cord.
2. Press and hold “V-” and “
b
” keys, simultaneously, and then plug the AC power cord.
3. “K” appears on the screen.
4. Press and hold “V-” and “P-” keys, simultaneously.
5. “SHARP FACTORY MENU” appears (see Figure 1).
6. Unplug the AC power cord to exit of adjustments process.
2. By own R/C
1. Turn on the TV set.
2. Press “
b
”,”2”,”5”, “8”, “0” (the time is limited to 5 sec. approx., for enter this code).
3. “SHARP FACTORY MENU” appears (see Figure 1).
4. Press “OK” on lines 5 ~ 12 to go to submenu.
5. Press “MENU” to return to main menu.
6. Press “END” to exit of adjustments mode.
* For Lx220 models it is not possible replace IC1007. Replace the full Main Unit.