Training course: D44
60
SEES Engineering Department
5. LCD Adjustment Process
(continued)
MAXIMUM VOLUME [60]
VOLUME FIXED [VARIABLE]
VOLUME FIXED LEVEL
[0]
RC BUTTON [RESPOND]
PANEL BUTTON [RESPOND]
MENU BUTTON [RESPOND]
ON SCREEN DISPLAY [YES]
INPUT MODE START [NORMAL]
INPUT MODE FIXED [VARIABLE]
RESET
EXECUTE
POWER ON FIXED
[VARIABLE]
Pu
bl
ic
Mode
HOTEL MODE
How to Enter in the Public Mode (Hotel Mode)
There are three following ways to display the Public Mode setting screen.
1- On the process adjustment mode screen (2/33), set the “HOTEL MODE” Flag to ON.
Turn off the power, and turn it on again, pressing the CH▲ and Vol▲ keys of the main
unit at the same time.
2- Enter the Pass Word, and start the unit.
a) Turn on the power, pressing the INPUT and Vol▲ keys of the main unit at the
same time.
b) Display the Pass Word input screen.
c) Check the Pass Word by inputting three digits. If the Pass Word is
, it
shifts to the Public Mode setting screen. In another case, the screen is erased, and it
operates in the ordinary mode.
3- By special R/C code: RC table LCD, SYS CORD: 0x78, RC DATA: (HEX) 0xC7,
(DEC) 199.
After one of sequence before mentioned, the TV will turn on showing the Public Mode
setting screen.
Exiting the Public Mode screen
There are two following ways to exit the Public Mode setting screen.
1- Turn off the power.