9. White Balance Adjustment
9-1. White balance adjustment
Adjustment point
Adjustment conditions
Adjustment procedure
1. Carry out aging for approx. 60 minutes.
2. Connect the white balance adjustment jig (luminance meter).
[Adjustment procedure]
Adjustment gradations values (IN) are shown on Page 9, and adjustment
initial values (OUT), on Pages 10 and 11, respectively. For white balance
adjustment, adjust the OUT values shown on Pages 10 and 11.
Set the specified gradation for point 6, and adjust RGB to the reference
values of point 6.
Set the specified gradation for point 1. Set G of point 1 to the default value
[(adjusted G value of point 6)/896, with fractions rounded] and adjust RB to
the reference values of point 1.
Set the specified gradation for point 2. Set G of point 2 to the default value
[(adjusted G value of point 6)/896, with fractions rounded] and adjust RB to
the reference values of point 2.
Set the specified gradation to point 3. Set G of point 3 to the default value
[(adjusted G value of point 6)/896, with fractions rounded] and adjust RB to
the reference values of point 3.
Set the specified gradation to point 4. Set G of point 4 to the default value
[(adjusted G value of point 6)/896, with fractions rounded] and adjust RB to
the reference values of point 4.
Set the specified gradation to point 5. Set G of point 5 to the default value
[(adjusted G value of point 6)/896, with fractions rounded] and adjust RB to
the reference values of point 5.
[Reference values for adjustment reference]: Luminance meter [Minolta
CA-210]
Point 1 reference values: x = 0.272, y = 0.277 (98 gradations) (196
gradations)
Point 2 reference values: x = 0.272, y = 0.277 (136 gradations) (272
gradations)
Point 3 reference values: x = 0.272, y = 0.277 (248 gradations) (496
gradations)
Point 4 reference values: x = 0.272, y = 0.277 (324 gradations) (648
gradations)
Point 5 reference values: x = 0.272, y = 0.277 (396 gradations) (792
gradations)
Point 6 reference values: x = 0.272, y = 0.277 (448 gradations) (896
gradations)
Specified value for adjustment:
±
0.004
Specified value for inspection:
±
0.006 (point 1)
Specified value for adjustment:
±
0.002
Specified value for inspection:
±
0.004 (other than the above)
1
Adjustment
Place a luminance
meter on the center of
the screen.
2
Auto adjustment
Содержание LC-26AF3 M/H/X
Страница 33: ...LC 26AF3 M H X LC 32AF3 M H X LC 37AF3 M H X 33 11 3 List of adjustment process modes Display ...
Страница 51: ...LC 26AF3 M H X LC 32AF3 M H X LC 37AF3 M H X 51 M E M O ...
Страница 66: ...78 6 5 4 3 2 1 A B C D E F G H LC 26AF3 M H X LC 32AF3 M H X LC 37AF3 M H X Side A Ë POWER Unit ...
Страница 67: ...79 6 5 4 3 2 1 A B C D E F G H LC 26AF3 M H X LC 32AF3 M H X LC 37AF3 M H X Ë POWER Unit Side B ...