LC-24LE170I
6 – 3
B. WHITE BALANCE ADJUSTMENT
a) White Balance Adjustment
NO
.
ITEM
CONDITION
PROCEDURE
i
Setting
Backlight : MAX
AV Mode : DYNAMIC
Active Backlight : OFF
Set the luminance
meter on the centre of
the screen
For the details of white balance adjustment procedure, please refer to white balance
adjustment spec for Kameyama model.
1. Confirm the set condition.
2. Connect the white balance jig.
3. Through RS-232C command, adjustment mode screen is displayed.
ii
Auto
Adjustment
[command]
Adjustment
Mode
KRSW0001
KKT10037
Setting
KYOF0001
OSDS0001
SBSL0016
Multi point
adj. Mode
MSET0000
WBI20255
Point 2
WBI20
227
MG2G****
MG2B****
MG2R****
Point 1
WBI10051
MG1G****
MG1B****
MG1R****
Write
MSET0003
Set
Max.Level
MGMG****
MGMR****
MGMB****
Initial setting
Panel Contrast
R/G/B_MAX
R/G/B_HIGH
R/G/B_LOW
C
nt
=
3000
:1
WB
MAX
= 4080
WB
H
=
3664
/4080
WB
L
= 816/4080
(1) Measurement MAX Brightness
(2) Set
MIN Brightness
(3) Measurement HIGH Brightness
(4) Measurement LOW Brightness
(5) Calculation H
γ
(6) Calculation L
γ
(7) Calculation HIGH luminance (
γ
=2.2)
(8) Calculation Initial setting of R/G/B_HIGH
(9) Set
Initial setting of R/G/B_HIGH
(10) Original WB adjustment is performed (HIGH)
Set the specified gradation for point 2, fix the
most faint colour to get reference value, adjust
others 2 colours to minus adjustment for
reference value of point 2.
(11) Measurement HIGH Brightness
(Set)
R_HIGH= G_HIGH
G_HIGH= G_HIGH
B_HIGH= G_HIGH
(12) Calculation MAX luminance after WB
ADJ set to
γ
=2.2 (L
XHG
)
(13) Set
R/G/B_MAX
(14) Calculation LOW luminance (
γ
=2.2)
(15) Calculation Initial setting of R/G/B_LOW
(16) Set
Initial setting of R/G/B_LOW
(17) Original WB adjustment is performed (LOW).
Set the specified gradation for point 1. adjust RB
to the reference value of point 1.
(18) Adjusted value is writing at [command]
MSET0003
(19) Calculate the slope R2
slope,
G2
slope,
B2
slope
between MAX and Point2.
R2
slope =
(R
max
- R
high
)/(4080-
3664
)
L
max
=305.7 cd/m²
L
min
= L
max
/C
nt
= 0.102
L
XH
=235.1 cd/m²
L
XL
=2.06 cd/m²
H
γ
=LOG((L
XH
-L
min
)/(L
max
-L
min
))/LOG(WB
H
/WB
MAX
)= 2.44
L
γ
=LOG((L
XL
-L
min
) /(L
max
-L
min
))/LOG(WB
L
/WB
MAX
)=2.73
L
H22
=(L
max
-L
min
) x (WB
H
/WB
MAX
)^2.2+L
min
=241.31
WB
HX
=WB
MAX
X ((L
H22
-L
min
)/(L
max
-L
min
))^(1/H
γ
)=3703
R_HIGH=WB
HX
’=3703
G_HIGH=WB
HX
’=3703
B_HIGH=WB
HX
’=3703
R_HIGH=3702
G_HIGH=3641
B_HIGH=3703
R_HIGH=3641
G_HIGH=3641
L
XHG
=
231.3
B_HIGH=3641
L
XMX
=L
XHG
/((W
B
H
/WB
MAX
)^2.2)=293.04
R_MAX=G_MAX*(R_HIGH/G_HIGH)=4078
G_MAX=WB
MAX
X ((L
XMX
-L
min
)/(L
max
-L
min
))^(1/H
γ
)=4010
B_MAX=G_MAX*(B_HIGH/G_HIGH)=4078
L
XLX
=(L
XMX
-L
min
) x (WB
L
/WB
MAX
)^2.2+L
min
=5.08
WB
LX
=WB
MAX
X ((L
XLX
-L
min
)/(L
max
-L
min
))^(1/L
γ
)=901
R_LOW=WB
XLX
=901
G_LOW=WB
XLX
=901
B_LOW=WB
XLX
=901
R_LOW= 921
G_LOW=901
B_LOW=971
Example: G6 panel also use for G8/
CSOT, CMI (be careful of INT setting)
RESULT
RESULT