6. The result is displayed within a minute as follows.
Figure 85
When an error occurs, the corresponding message appears. Solve the problem according to “Solution”.
•
Error 1
Error message: “There are too many black cracks.”
Cause: The light is too weak or strong.
Solution: At the proper distance from the light source (8,000 - 10,000 lux), perform black defect correction again.
•
Error 2
Error message: “There are many black cracks.”
Cause: The light is too weak or strong.
Solution: At the proper distance from the light source (8,000 - 10,000 lux), perform black defect correction again.
•
Error 3
Error message: “There are too many black cracks cannot be rectified.”
Cause: There is a hardware error.
Solution: Replace the camera unit.
4.9. ****mode release
When the handset does not turn on and enter the normal mode, use this function to change ****mode to the normal mode.
<Operation>
1) Select the COM port on the SPST initial screen and click “****mode release”. The following dialog box appears.
Figure 86
2) If SPST cannot communicate with the handset, the following message is displayed. Make sure the handset is turned on and click “Retry”. To exit,
click “Cancel”.
Figure 87
3) When complete, the following message appears.
Figure 88
Содержание GX30
Страница 6: ...GX30 1 4 CONFIDENTIAL 12 New Messages Download Games News Sport ...
Страница 7: ...GX30 1 5 CONFIDENTIAL 1 3 6 3 3 7 5 ...
Страница 8: ...GX30 1 6 CONFIDENTIAL MEMO ...
Страница 91: ...GX30 5 4 CONFIDENTIAL VSYNC Stand by C760 SUBFLM Stand by L711 1Pin 16 17 TCXOEN Stand by IC804 1Pin 18 ...
Страница 120: ...GX30 5 33 CONFIDENTIAL MEMO ...
Страница 150: ...GX30 6 30 CONFIDENTIAL MEMO ...
Страница 165: ...GX30 15 INDEX MEMO ...