E-6
WIRE CONTROLLER OPERATION
• When the unit is not operating, timer start can be set.
When the unit is operating, timer shutoff can be set.
The range of timer setting is between 0.5 to 24 hours.
Press the TIMER button to enter the timer set status.
The word “TIMER” will flash on the display.
2 Press ( ) or ( ) button to increase or decrease the
set time.
3 Press the TIMER button again. The timer will go into
effect. The unit will start to count the time passed.
To cancel timer setting, press the TIMER button.
• When the unit is shut off, press the FAN button
and the ( ) button simultaneously for 5 seconds to
activate the SAVE setting menu.
The “SAVE” and “COOL” will be displayed (For the
first setting, the initial value will be displayed: 26) .
The lower limit of temperature will be displayed on the
set temperature area and the temperature value will
be flashed. Set the lower limit of cooling temperature
to press the ( ) button or the ( ) button. (rang of
setting : 6-30).
Press the ON/OFF button to confirm the setting. Use the (
) button or the ( ) button to
set the upper limit of temperature and the temperature value will flash on the ambient
temperature area (OUT ENV area). (rang of setting : 6-30).
Press the ON/OFF button to confirm the setting. Take care that the upper limit temperature
must be higher than the set lower limit temperature; Otherwise the system will regard the
higher temperature as the upper limit temperature and the lower one as the lower limit
temperature.
Press the MODE button to complete the SAVE setting for the modes of cooling and
dehumidifying and turn to the SAVE setting for the heating mode. The “SAVE” and “HEAT”
will be displayed. After setting is completed, press the FAN button and the ( ) button
simultaneously for 5 seconds to exit the SAVE setting. After the SAVE setting interface is
activated, the system will exit the interface if there is no any operation within 20 seconds
after the last button input, and the normal shutoff status interface will be displayed. After
the above settings are completed, the system will display “SAVE”. The set temperature
will not exceed the temperature range of the SAVE setting. For example, the lower cooling
limit is set to 23°C and the upper cooling limit is set to 27°C, so the cooling temperature
can only be selected from the range of 23°C to 27°C by using the remote controller or the
wire controller. If the upper limit temperature is the same as the lower limit temperature,
the system can only operate at this temperature under corresponding mode.
To cancel the SAVE setting, press the FAN button and the ( ) button simultaneously for 5
seconds when the unit is shut off. The value set before will not be cleared but as the initial
set temperature for the next energy saving setting.
After the unit is disconnected to power supply, the SAVE setting will be memorised. The
setting still functions when the unit is connected to power supply again. If the SAVE mode
is set, the sleep mode and the auto mode will be invalidated.
Timer setting
SAVE setting