EN-10

TROUBLESHOOTING

SYMPTOM

REMEDY (not a malfunction)

Odors and smoke are not removed.

•  Replace the filters if they appear to be heavily soiled.

 

(page 9)

The Cleanliness Monitor illuminates blue 

even when the air is impure.

•  The air could be impure at the time the main unit was plugged in.

  Unplug the main unit, wait one minute, and plug the main unit in again.

The Cleanliness Monitor illuminates 

orange or red even when the air is 

c

lean.

•  Sensor operation is affected if the dust sensor openings are dirty or 

clogged. Gently clean the dust sensor openings. (page 8).

A clicking or ticking sound is heard from 

the main unit.

•  Clicking or ticking sounds may be audible when the main unit is 

generating ions.

The discharged air has an odor.

•  Check to see if the filters are heavily soiled. 

•  Clean or replace the filters.

•    Plasmacluster Air Purifiers emit small traces of ozone which may produce 

an odor.

The unit does not operate  properly when 

cigarette smoke is in the air.

•   Is the unit installed in a location that is difficult for the sensor to detect 

cigarette smoke?

•  Is the dust sensor opening blocked or clogged?

   (In this case, clean the opening.) (page 8)

The Cleanliness Monitor is turned off.

•  Check to see if the Lights OFF Mode selected. 

   Press 

 for 3 seconds to light On. (page 7)

•  Check to see if the SLEEP mode is selected.

  

 The Cleanliness Monitor/ Plasmaclustor Ion Light  are turned off 

automatically after the SLEEP mode is selected.

The Cleanliness Monitor lights change 

color frequently.

•  The Cleanliness Monitor lights automatically change colors as impurities 

are detected by the dust sensor.

The SLEEP lamp is flashing.

•  Fan motor error. Turn the power OFF. 

  Wait one minute, and then turn the power ON.

AUTO RESTART
After a power failure, automatically 

resume the operation when the power 

recovers.

Auto Restart can be set.

•  

Even when the plug is unplugged or the breaker is thrown during the 

operation, the operation resumes at the previous operation mode and 

settings if the power recovers.

Before calling for service, please review the Troubleshooting chart below, since the problem may not be a unit 

malfunction.

ON

OFF

(with the main unit OFF)

(with the main unit OFF)

If the       ,     ,     ,       lamp Lights up  

for 8 seconds, the setting is completed.

(simultaneously for

 more than 3 sec.)

(simultaneously for

 more than 3 sec.)

OM_FP-J40E_40L_EN.indd   10

2018/06/25   11:44:41

Содержание FP-J40E

Страница 1: ...asured around the center of a room with the high density plasmacluster 7000 applicable floor area at 1 2 m height above the floor at the medium wind volume in air purifying mode when an air purifier using the high density plasmacluster ion evolving device is placed close to a wall This product is equipped with a device corresponding to this capacity AIR PURIFIER OPERATION MANUAL ENGLISH MALAYSIA P...

Страница 2: ...absorbed by the filters may break down over time resulting in additional odor Depending on the usage environment especially when the product is used in extreme environments significantly more severe than normal household use this odor may become strong in a shorter period than expected If the odor persists the filters should be replaced The air purifier is designed to remove air suspended dust and...

Страница 3: ...HOOTING EN 10 SPECIFICATIONS EN 11 CONTENTS FEATURES Unique Combination of Air Treatment Technologies Triple Filtration System Plasmacluster TRAPS DUST Pre Filter traps dust and other large airborne particles DECREASES ODORS Deodorizing filter absorbs many common household odors REDUCES POLLEN MOLD HEPA filter traps 99 97 of particles as small as 0 3 microns FRESHENS Plasmacluster treats the air s...

Страница 4: ...placed by the manufacturer its service agent Sharp Approved Service Center or similarly qualified person in order to avoid a hazard Do not operate when using aerosol insecticides or in rooms where there is oily residue incense sparks from lit cigarettes chemical fumes in the air or in very high humidity conditions such as a bathroom Be cautious when cleaning the main unit Corrosive cleansers may d...

Страница 5: ...the air intake and or air outlet Avoid use in locations where the unit is exposed to condensation or drastic temperature changes Appropriate conditions are when room temperature is between 0 35 ºC Place on a stable surface with sufficient air circulation When placing the unit on a heavily carpeted area the unit may vibrate slightly Avoid locations where grease or oily smoke is generated The unit s...

Страница 6: ...macluster Ion ON OFF Button 14 Deodorizing Filter 15 Back Panel Pre Filter 5 HAZE Button indicator Light white 16 Bottom Tabs 6 POWER ON OFF Button 17 Plug Shape of plug depends on country 7 Light Sensor 8 Odor Sensor 18 Power Cord 9 Plasmaclustor Ion Light blue FRONT BACK 16 13 14 10 11 12 15 Cleanliness Monitor Indicates the air purity of the room in 3 levels with color changes Blue Orange Red C...

Страница 7: ...Do not operate the unit without the filter Be sure to remove the power plug from the wall outlet 3 Place the Filter within the main unit Do not install the filter backwards or the unit will not operate properly 4 Replace the Back Panel to the main unit HEPA Filter Deodorizing Filter 1 Remove the Back Panel 2 Remove the plastic bag from the Filter Click Pull OM_FP J40E_40L_EN indd 5 2018 06 25 11 4...

Страница 8: ...r switching mode FAN SPEED OFF TIMER Select the length of time you want with the main unit on The main unit automatically stops once the selected time is reached START STOP NOTE NOTE AUTO The fan speed is automatically switched depending on the amount of impurities in the air The sensors detect impurities for efficient air purfication SLEEP The unit will operate very quietly and the fan speed is aut...

Страница 9: ...e Dust sensor Odor sensor and the Light sensor If the power OFF Button is not pushed within 8 seconds of adjusting sensor sensitivity the setting will be saved automatically The sensor sensitivity setting will be saved even if the main unit is unplugged NOTE 1 2 3 with the main unit OFF more than 3 sec more than 3 sec more than 3 sec AUTO DIM OFF 1 2 Standard High Low 4h 8h 2h Standard High Low Du...

Страница 10: ...ing a vacuum cleaner attachment or similar tool Dust sensor Odor sensor FILTERS Tag HEPA Filter Deodorizing Filter CAUTION Gently remove dust from HEPA Filter and Deodorizing Filter with a vacuum cleaner attachment or similar tool Do not WASH in water and DRY in the sun The filters are fragile be careful not to apply too much force HEPA Filter Apply the maintenance only on the side with the tag Do...

Страница 11: ...ironment usage and location of the unit We recommend to replace the filter more frequently if the product is used in a condition significantly severer than normal household use HEPA Filter About 2 years after opening Deodorizing Filter About 2 years after opening The Replace Filter indicator light will turn on after approximately 17 500 hours 2 years 24 hours 17 500 Conditions Mode sleep Light Dar...

Страница 12: ...dust sensor opening blocked or clogged In this case clean the opening page 8 The Cleanliness Monitor is turned off Check to see if the Lights OFF Mode selected Press for 3 seconds to light On page 7 Check to see if the SLEEP mode is selected The Cleanliness Monitor Plasmaclustor Ion Light are turned off automatically after the SLEEP mode is selected The Cleanliness Monitor lights change color freq...

Страница 13: ...ing the unit at maximum fan speed It indicates the space where a certain amount of dust particles can be removed in 30 minutes JEM1467 3 Size of a room in which approximately 7000 ions can be measured per cubic centimeter in the center of the room at a height of approximately 1 2 meters from the floor when the product is placed next to a wall and run at the MED opera tion position Standby Power In...

Страница 14: ...Printed in Thailand TINS B147KKRZ 18G 1 OSAKA JAPAN SHARP CORPORATION OM_FP J40E_40L_EN indd 12 2018 06 25 11 44 42 ...

Отзывы: