FO-77U
UX-66U
2 – 16
SW-D2 No. 1 ~ No. 3 Distinctive ringing setting
When the ringing setting is turned off, all of the CI signals are received.
When any of the standard, and ring patterns 1 through 3 is selected for
the ringing setting, only the selected CI signal is received.
CI signal patterns
The CI signal patterns consists of the standard pattern, and ring pat-
terns 1 through 7. The standard pattern is the conventional one.
SW-D2 No. 4, No. 5 Reserved
Set to "0".
SW-D2 No. 6 Caller ID Function
Used for Caller ID function.
SW-D2 No. 7, No. 8 Reserved
Set to "0".
SW-D3 No. 1 ~ No. 5 CI off detection timer
(0~1550ms setting by 50ms step)
Set the minimum time period of CI signal interruption which affords to be
judged as a CI OFF section with 50ms steps.
(Example)
0 1 1 1 0 (50ms~14) : 700ms(CI interruption>700ms:Judged as a CI
OFF section)
The section 1 is not judged as a CI OFF sec-
tion, the CI signal A is counted as one signal.
The section 2 is judged as a CI OFF section,
the CI signal B is considered as the second sig-
nal.
0 0 1 1 1 (50ms~7) : 350ms(CI interruption>350ms:J udged as a CI
OFF section)
The section 1 is judged as a CI OFF section,
and the CI signal A is counted as two signals.
The section 2 is judged as a CI OFF section,
and the CI signal B is considered as the third
signal.
SW-D3 No. 6 ~ No. 8 Reserved
Set to "0".
SW-D4 No. 1 ~ No. 6 DTMF type Caller ID RX level
(0~-44dBm setting by 1dBm step)
This is used for DTMF type Caller ID detection level setting.
SW-D4 No. 7, No. 8 Reserved
Set to "0".
SW-E1 No. 1 ~ No. 8 Reserved
Set to "0".
SW-E2 No. 1 ~ No. 8 Reserved
Set to "0".
SW-E3 No. 1 ~ No. 8 Reserved
Set to "0".
SW-F1 No. 1, No. 2 DTMF detection time
Used to set detect time of DTMF (Dual Tone Multi Frequency) used in
remote reception(5
).
The longer the detect time is, the less the error detection is caused by
noises.
SW-F1 No. 3 Protection of remote reception (5
) detection
Used to set the function of remote reception (5
). When set to "1",
the remote reception function is disabled.
SW-F1 No. 4 Remote reception with GE telephone
"1": Compatible with TEL mode by GE
"0": Not compatible
• When sending (5
) for remote reception with a GE manufactured
telephone remote reception may not take place because of special
specifications in their DTMF.
To overcome this, a soft SW is provided to change the modem setting
to allow for remote reception.
• If this soft SW is set to "1", other telephone sets may be adversely
affected.
SW-F1 No. 5 ~ No. 8 Remote operation code figure by external TEL
(0~9)
Remote operation codes can be changed from 0 through 9. If set to
greater than 9, it defaults to 9. The "5
" is not changed.
Ex- 7
(Default : 5
)
A
B
400msec
2000msec
1
2
1S
3.5S
1S
0.5S
RING
PATTERN 1
for CANADA
2S
4S
1.5S
3S
1S
4S
1.5S
4S
0.8S
4S
0.3S
4S
0.4S
4S
1S
3S
0.5S
3S
0.5S
3S
2S
2S
0.5S
0.5S
1S
0.2S
0.8S
0.4S
0.3S
0.2S
0.4S 0.8S
0.2S 0.2S
1S
1S
1S
0.5S
0.5S
0.5S
0.5S
1S
0.5S
0.5S
STANDARD
RING
PATTERN 1
for USA
RING
PATTERN 2
for USA
RING
PATTERN 3
for USA
RING
PATTERN 2
for CANADA
RING
PATTERN 3
for CANADA
Содержание FO-77
Страница 65: ...FO 77U UX 66U Control PWB parts layout Top side 6 7 ...
Страница 66: ...FO 77U UX 66U Control PWB parts layout Bottom side 6 8 ...
Страница 69: ...FO 77U UX 66U TEL LIU PWB parts layout Top side 6 11 ...
Страница 70: ...FO 77U UX 66U 6 12 TEL LIU PWB parts layout Bottom side ...
Страница 72: ...FO 77U UX 66U Power supply PWB parts layout 6 14 RDENT2142XHZZ F2 ...
Страница 97: ...FO 77U UX 66U 14 M E M O ...