COMMUNICATIONS
Specifications subject to change without notice:
Revision date 10/07
Page 191
of 266
Quick Steps – Communications
To quickly setup the ER-A520 and ER-A530 to interface with the Communications software
(example: SDW or some other software), please refer to the related procedures below:
No.
Description
Comments/Procedure
Step–1
Connect SDW
CH–1 or CH–2
Step–2
PGM Job#2690
2690
Æ
[.]
Æ
[@]
Æ
1
Æ
@
Æ
1000 [SBTL]
Æ
[CA/AT] for CH–1)
or
2690
Æ
[.]
Æ
[@]
Æ
1
Æ
@
Æ
2000 [SBTL]
Æ
[CA/AT] for CH–2)
Note:
Must match the physical connection
Step–3
Program Reset
•
Place the SRV-Key counter-clockwise to 6 o’clock position (SRV’ position)
•
Count 5 seconds
•
Turn SRV-Key clockwise to 7o’clock position (SRV position)
•
Verify”***PROGRAM RESET has printed on the journal-side tape.
Step-4
PGM Job#6110
6110
Æ
[.]
Æ
[@]
Æ
000001
Æ
[CASH]
(Online Terminal No.)
Note:
Leave at MRS defaults (Terminal = 000001)
Step-5
PGM Job #6111
6111
Æ
[.]
Æ
[@] AB
Æ
[CASH]
(RS232 Transmission)
Note:
Leave at MRS defaults (AB = 00)
Step-6
PGM Job#6112
6112
Æ
[.]
Æ
[@]
Æ
AB
Æ
[CASH]
(RS232 Functions)
A: RS232 Baud Rate 38400/19200/9600/4800 bps = 7/6/5/4
Note:
MRS defaults is 19200 bps (or 6)
Step-7
PGM Job #6113
6113
Æ
[.]
Æ
[@]
Æ
xxxyyy
Æ
[CASH]
(Start & End Code)
Note:
Leave at MRS defaults (or 002013)
Step-8
PGM Job #6115
6115
Æ
[.]
Æ
[@]
Æ
xxx
Æ
[CASH]
(Time Out) 1
st
Response Wait
Note:
Leave at MRS defaults (or 007)
Step-9 PGM
Job#6220 6220
Æ
[.]
Æ
[@]
Æ
ABC
Æ
[CASH]
(Print Data Sending)
A: Sensing of DTR No/Yes = 1/0
B: Sensing of CS No/Yes = 1/0
C: Sending of Print All Data Yes/No = 1/0
Note:
PGM Job #6112-A must be = 1
Содержание ER-A520
Страница 2: ......
Страница 4: ......
Страница 5: ...Section 1 System Presets ...
Страница 6: ......
Страница 34: ......
Страница 35: ...Section 2 Free Key Layouts ...
Страница 36: ......
Страница 46: ......
Страница 47: ...Section 3 File Allocation ...
Страница 48: ......
Страница 55: ...Section 4 PERIPHERALS ...
Страница 56: ......
Страница 71: ...PERIPHERALS Specifications subject to change without notice Revision date 10 07 Page 65 of 266 ...
Страница 103: ...Section 5 PGM Mode Programming ...
Страница 104: ......
Страница 187: ...Section 6 Communications ...
Страница 188: ......
Страница 198: ......
Страница 199: ...Section 7 Credit Card Authorization ...
Страница 202: ......
Страница 208: ...ER A520 A530 Dealer Knowledge Book Page 202 of 266 Specifications subject to change without notice Revision date 10 07 ...
Страница 227: ...Section 8 Utilities ...
Страница 228: ......
Страница 243: ...Section 9 SSP s ...
Страница 244: ......
Страница 249: ...Section 10 FLASH ROM ...
Страница 250: ......
Страница 259: ...Section 11 LOGO UTILITY ...
Страница 260: ......
Страница 273: ......
Страница 274: ......