ADAPTATION TO ’96 CHLOROFLUOROCARBON REGULATIONS

(1) Outline

As the chlorofluorocarbon used for freezers and heat insulators of refrigerators depletes the ozone layer, it has been
decided to abolish completely the production of chlorofluorocarbon by the end of 1995 and to use the substance less
adversely affecting the ozone layer in the world scale.  Now, Sharp uses the chlorofluorocarbon replacing substance
HFC-134a for refrigerator coolant.  It is applied also for the new models of dehumidifier DW71-H.

(2) Properties of HFC-134a cycle and cautions

1) Cares when changing the coolant

(Change from CFC-12 to HFC-134a)
(1) As the Filter dryer for CFC-12 cannot be used, the Dryer filter for HFC-134a must be used.  (However, the

dryer XH-9 for HFC-134a can be used for CFC-12.)  As the size of coolant molecular is smaller, the different
drying agent is used.

(2)  The existing gas leak tester (for CFC-12 and HCFC-22) cannot be used.

(The existing leak tester detects chlorine contained in chlorofluorocarbon, but HFC-134a does not contain
chlorine.)

(3)  The repair tools for HFC-134a must be used.  (There are specific tools for refrigerator and dehumidifier.  Refer

to the instructions.)
The rubber (sealing) of existing tools expands and its tension reduces.  The specified tools must be used
(using the  rubber of other type).

2)   Change of compressor oil

Naphthene mineral oil or V-olefine synthetic oil (CFC-12) is changed to ester oil for the refrigerator and to non-
ester oil (low-viscosity alkylbenzene) (HFC-134a) for the dehumidifier.
(1) After opening the cap of each refrigerator, dehumidifier, compressor and Dryer filter , it is necessary to

evacuate it within 15 minutes.
Non-ester oil and particularly ester oil have the saturation molar weight of 200 ppm, 40 times more than the
existing oil.
(Since non-ester oil and particularly ester oil are liable to react with water to produce acid, the acid reacts with
metal into metallic salt which becomes a cause to clog the capillary tube. Particularly after opening the plug of
each compressor and Dryer filter , it is necessary to strictly take care for the time control.)

(2) The tools applicable for the refrigerator are designated (HFC-134a special).

Some tools for the dehumidifier are commonly applicable for the refrigerator (refrigerant bomb and charging
cylinder for HFC-134a and vacuum pump for R-12) and the other tools which are designated [HFC-134a
special for dehumidifier] 
are special for the dehumidifier. (Here, add the check valve of special tools for

dehumidifier when using the vacuum pump for R-12.) Take care to clearly discriminate the tools during use.

Moreover, it is necessary to surely wash and clean new parts.
Among non-ester oil for the dehumidifier and ester oil for the refrigerator, the solubility of the ester oil for the
existing oil (compressor oil for CFC-12, and rust-preventive oil used on the coupler and pressure gauge) is
extremely as low as 10 ppm to 20 ppm. Therefore, if any slight amount of the existing oil is mixed into the
cycle, it will deposit at the outlet of the capillary tube to become a cause of clogging.
Accordingly, it is inhibited to use any other tool (some existing oil may mix into the refrigeration cycle) which
is not applicable for the dehumidifier or refrigerator and it is necessary to surely wash and clean new tools
even if they are applicable as HFC-134a.

(3) It is necessary to prevent mixing non-ester oil for dehumidifier with ester oil for refrigerator.

Since it may be easily influenced by the stability (moisture or other mixed material) of ester oil itself,

generation of sludge will be promoted as described above, thus resulting in clogged capillary tube.

Take care never to recharge HFC-134a refrigerant to the unit which has been charged with CFC-12 in
the refrigeration cycle or with other refrigerator oil.

(4) Inhibition of use of flux during welding

Though steel pipe and copper pipe are
not welded as basic, it is inhibited to use
flux since it may enter the cycle if flux
dissolved into the water is used.

3)  Replacing air with nitrogen when brazing

(1)  Oxide scale in the piping which is formed

in brazing process may cause clogging
of capillary tube.
Therefore the air in the piping must be
replaced with nitrogen when brazing is
performed.

Refrigerant 1

Lubricant

Wear resistance

Sludge generation

Electric insulation

Compatibility 
(solubility into 
 refrigerant)

CFC-12

Mineral oil

Ester type

(For refrigerator)

HFC-134a

Non-ester type
(Low-viscosity 
alkylbenzene oil)

(For dehumidifier)

Comparison of lubricant for HFC-134a

(much)

(a little)

(a little)

4) Vacuum (improvement of accuracy of vacuum)

(1) Follow the specified evacuation and gas charging procedure.

The vacuum to be attained must be 0.5 Torr or below.

Содержание DW-71-H

Страница 1: ... OF OPERATION 17 TROUBLESHOOTING AND CORRECTIVE ACTIONS 21 LIST OF TROUBLES AND CORRECTIVE ACTIONS 22 ADAPTATION TO 96 CHLOROFLUOROCARBON REGULATIONS 25 HFC 134a CYCLE REPAIR PROCEDURE 26 PACKING 34 REPLACEMENT PARTS LIST 35 TABLE OF CONTENTS In the interests of user safety Required by safety regulations in some countries the set should be restored to its original condition and only parts identica...

Страница 2: ... to water splashes This can cause electric shock or fire Do not install the unit at locations where oil or combustible gas leakage can occur Leaked oil or gas near the unit can cause fire Donotputavesselcontainingwatersuchasvaseontheunit Dripped water on the unit can lower the rate of electric insulation resulting in electric shock electrical leakage or fire This unit is for in door use only Do no...

Страница 3: ...reeze and undrained water might spill in the room When operating Warning Important Do not stick your finger or any object into the air outlets or intake The rotating internal fan can cause injuries Do not operate the unit with voltages other than the rated voltage of 230V This can result in electric shock or fire Do not use an extension power supply cord or share the socket with other electrical a...

Страница 4: ...t the air from passing and result in overheating or fire 5 cm or more Do not stand or sit on the unit Injury can be resulted if you fall down or the unit topples Do not wash the unit directly with water This can result in electric shock Do not place the unit near combustible equipment or under direct sunlight This can affect the combustible performance of the equipment Do not unplug by pulling the...

Страница 5: ...ire Repair Warning Do not disassemble the dehumidifier Do not modify the unit This can cause fire electric shock or injuries This unit should not be disassembled or repaired by persons other than qualified technician Otherwise this might be resulted in fire electric shock or injuries Unplug from the socket When any abnormality for example burning smell is found turn the power off unplug the unit a...

Страница 6: ...Discharge water elbow Overall size Weight Power supply cord Dehumidification enable area Refrigerant SPECIFICATION DW 71 H 6 3 L day daily dehumidifying capacity in conditions of room temperature 27 C and relative humidity 60 230V 50Hz 1 0A 187W 190W Rorary compressor output 100W model XB357RCA Plate type with forced draft Plate type with forced draft Hot gas defrosting ø160 sirocco fan Shading Co...

Страница 7: ...ure may increase by about 2 5 C depending upon the operating conditions outside temperature room size As the drying and dehumidifying machine is used in closed room the room temperature rises in the summer Even when the drying and dehumidifying machine is used the humidity lower than approx 50 cannot be maintained There is no possibility however of excessive drying Principle of dehumidifying funct...

Страница 8: ...diagonally downward direction Continuous drainage hole Used for draining water continuously Power supply cord Carrying handle Pull out the handle when moving the unit Carrying handle Cord clamp Plug Control Panel FULL lamp Lights when the water tank is full DEFROSTING lamp Lights when defrosting is carried out DEHUMIDIFYING lamp Lights during dehumidifying operation DRYING CLOTHES indicator lamp L...

Страница 9: ... humidity The graph shows the dehumidifying capacity at specified temperature and humidity 1 Dehumidifying mode The fan motor runs slowly and continuously 2 Drying clothes mode The fan motor runs continuously with high speed air flow rate is increased by 20 The fan sucks the wet air into the dehumidifier The air is cooled by the cooler and the water vapor is condensed Dews on the cooler flow down ...

Страница 10: ...ts about 12 the defrosting is ended and the normal operation is resumed The defrosting time is about 5 to 10 minutes 4 Hot gas defrosting system In the defrosting mode the solenoid valve is actuated and opened so that the hot gas flows in the arrow direction shown in the figure to remove the frost on the cooler In the defrosting mode the solenoid valve is actuated and opened so that the hot gas fl...

Страница 11: ...lbow into the unit Return the water tank Open the front door and let the open end of the hose pass through the hole Remove the water tank and punch out the continuous drainage hole on the back of the unit using a screwdriver and finish the edge with a knife Continuous draining hole A commercially available hose with a 15 mm inside diameter 10 mm or more Drain hose elbow Push the drain hose elbow i...

Страница 12: ...side of main unit Screw A 2 Remove four screws on the rear of main body Screw B Two screws on the bottom of main body are longer 3 Remove one screw at the center on the rear of main body Screw C Use the special screwdriver which matches the shape of the screw head as shown in the drawing The special screwdriver is used as a countermeasure to make the qualified engineer of the manufacturer or its r...

Страница 13: ... fan motor If the fan motor failed to run be sure to replace the fan together with the fan motor The fan vibrates more remarkably causing growing noise After removing the front and rear parts of main unit 1 Disconnect the connector of power supply PWB Screw Casing Display PWB harness Power supply PWB For fan motor Harness fixing rib Fan fixing screw Screw Casing Screw Screw Transfomer cover The tr...

Страница 14: ...ver to the right and then remove the remaining screws arrow mark Figure 4 2 below 2 Remove the connector Screw Up Screw To the right Screw Front part of main unit Switch box Red Low Screw Orange High Upper Gray Com Lower For compressor cord For defrosting lamp For magnetic coil For control For fan motor For power switch For power cord Waterproof rubber Waterproof rubber Switch box Button B for sel...

Страница 15: ... part of main unit disengage the rib of dew pan with which the switch holder is engaged and withdraw the switch holder FULL switch ass y Switch holder Rib Fixture Terminal cover CN B 1 IS 187 natural color Shinagawa Shoko Purple Red IS 187 natural color Shinagawa Shoko To FULL switch IS 187 natural color Shinagawa Shoko To FULL switch Orange Capacitor 4µF 430VAC Red Orange Blue Gray Insert into ho...

Страница 16: ...tank and insert the opposite side into the hole 3 Be sure to ascertain that the float flange lies on the protrusion of water tank Unless it lies on the protrusion operation is disabled 14 Removing the transformer 1 Remove the front and rear parts of main unit 2 Remove the power supply cover 3 Remove the screws 2 pcs fixing the transformer cover 4 Disconnect the connector of power supply PWB 11 Rem...

Страница 17: ...17 DW 71 H CIRCUIT DIAGRAM AND EXPLANATION OF OPERATION Circuit diagram ...

Страница 18: ...18 DW 71 H ...

Страница 19: ...borted and the regular operation is restored 3 Water fullness detection When the water tank is filled fully with water or the tank has not been installed correctly the water fullness state is set The compressor fan motor and solenoid valve are stopped and the FULL lamp lights When the water fullness state is cancelled the operation mode preceding to the water fullness state is resumed The defrosti...

Страница 20: ...20 DW 71 H 3 Location of PWB parts 1 Power supply PWB Parts side 2 Operation PWB Parts side ...

Страница 21: ...ying capacity is low Humidity does not decrease in each of the operating modes Unit operation is noisy Water is leaking Is the water tank set properly Is the water tank full Is the unit plugged properly Is the power supply OK Is the front filter and air filter clogged Is the air outlet or intake closed Is the temperature and the humidity of your room too low Is your room too wide Are the windows o...

Страница 22: ... sub winding Capacitor Power is not supplied when the switch lever is pressed ON FULL indication appears Capacitor opened or short circuited Protector opened Voltage detected Check parts of compressor Voltage not detected Check drive parts of compressor Power supply voltage not within 230V 10 When the compressor is started voltage is below 209V Sub winding opened Capacitor opened Replace the FULL ...

Страница 23: ... short circuited Power is supplied continuously even when the water tank is removed The float does not function normally Improper installation Contact failure FULL circuit wiring failure Lower than 1 C Overcharge Fan motor failure Defrosting thermistor failure Operation PWB ass y failure Defrosting thermistor failure Improper insertion of defrosting thermistor Connector contact failure Power PWB a...

Страница 24: ...24 DW 71 H ReferencesThermistor resistance Thermistor for defrosting Temperature C Resistance kΩ 5 0 237 1 0 179 5 2 5 156 6 5 0 137 0 10 0 105 3 12 0 95 02 15 0 81 59 20 0 63 65 25 0 49 99 ...

Страница 25: ...rigerator refrigerant bomb and charging cylinder for HFC 134a and vacuum pump for R 12 and the other tools which are designated HFC 134a special for dehumidifier are special for the dehumidifier Here add the check valve of special tools for dehumidifier when using the vacuum pump for R 12 Take care to clearly discriminate the tools during use Moreover it is necessary to surely wash and clean new p...

Страница 26: ... leaking part irrespective of whether it is at low pressure side or high pressure side Use the service parts of Dryer filter set for HFC 134a CDRY A001FBK0 with two evacuation pipes 1 List of service tools for dehumidifier specific use and common use For dehumidifier only Equipment name Gauge manifold Charging hose ass y Charging cylinder 3 way reducer for charging cylinder Check valve prevention ...

Страница 27: ...the servicing time Primary evacuation 5 min Gas charging approx 30 g Secondary evacuation 30 min Gas charging specified quantity Vacuum of secondary evacuation must be at least 1 Torr or below In case of primary charge charge the coolant from the low pressure side and discharge from the high pressure side In case of secondary charge charge from the high pressure side Caution 1 When evacuating be s...

Страница 28: ...uge manifold apply pressure approx 70 x 104 Pa approx 7 kg cm2 and check for leak with soapy water or testing liquid Monju If leak is found thoroughly wipe off the soapy water from the leaking part and then lower the nitrogen pressure so as to prevent entry of water into the pipe Caution Never use any flux when brazing Entry of water into the pipe causes cycle troubles Low pressuer High pressuer T...

Страница 29: ...ing Additional valve opening Low pressuer High pressuer Gauge manifold Low pressure pipe side High pressure pipe side Dehumidifier Refrigeration cycle 3 way reducer 3 8 3 8 10mm Liquid side Gas side Charging cylinder for HFC 134a Charge gas adijusting valves Valve opening Purge the inside of cylinder and hose Valve closing Valve opening Valve closing Valve opening Valve closing Valve closing Liqui...

Страница 30: ...ose the liquid side valve of charging cylinder and the high pressure valve of gauge manifold close all the valves To power source on off 1 2 3 4 Socket for vacuum pump Start of vacuum pump Check valve for vacuum pump Vacuum pump for R 12 Valve opening Valve opening Valve opening Low pressuer High pressuer Gauge manifold Low pressure pipe side High pressure pipe side Dehumidifier Refrigeration cycl...

Страница 31: ...cle Take care so that the air does not enter into the cycle Never allow reduction of gauge pressure below 1 0 kgf cm2 G 10 Tighten the joint A which has been loosed in Step 7 above Slightly open the liquid side valve of charging cylinder and close A discharging gas Purge the inside of hose on A off Check valve for vacuum pump Vacuum pump for R 12 1 2 3 4 4 5 6 7 8 Valve opening Valve opening down ...

Страница 32: ...igeration cycle Liquid side Gas side Charging cylinder for HFC 134a on off Check valve for vacuum pump Vacuum pump for R 12 1 2 3 4 4 4 Valve opening Valve closing Valve opening Siowly Valve closing Valve opening Siowly Valve closing Valve closing Valve closing Low pressuer High pressuer Gauge manifold Low pressure pipe side High pressure pipe side Dehumidifier Refrigeration cycle Liquid side Gas ...

Страница 33: ...in that the temperature of discharge pipe and condenser rises on off Check valve for vacuum pump Vacuum pump for R 12 Valve opening Valve closing Valve closing Valve closing Valve closing Tight close the servise pipe and braze the front end Tight close the servise pipe and braze the front end Valve closing 1 2 3 4 5 Low pressuer High pressuer Gauge manifold Low pressure pipe side High pressure pip...

Страница 34: ...flaps with staples Tape 40mm x 40mm Tow places at both sides fold back the tape Tape 25mm x 150mm fold back the tape Front door Water tank Tape 25mm x 150mm fold back the tape Power cord catch Power cord Fix the bottom flaps with staples Fix flaps with 4 staples Case 6 Insert the edges of outer top flaps of case into the slits of inner flaps to close the top Inner flap Outer flap Case Plug Plug pr...

Страница 35: ...08FBF0 Evaporating pan 1 AL 2 23 FFLO A007FBF0 Float 1 AG 2 24 JHND A001FBF0 Tank handle 1 AF 2 25 PTNKNA012FBRA Drain tank 1 AQ 2 26 LANG A030FBW0 Motor fixing angle 1 AH 2 27 NFANSA003FBE0 Centrifagal fan 1 AN 2 28 PDUC A007FBF0 Casing 1 AN 2 29 FBOX A010FBF0 Control box 1 AR 2 30 GWAKPA009FBFB Filter frame 1 AP 2 32 LHLD A006CDF0 Switch holder 1 AF 2 33 PLEV A004FBF0 Switch lever 1 AD 2 34 GCOV...

Страница 36: ...FBE0 Poly bag 1 AD 90 5 MJNT A001FBFA Pipe joint 1 AB 90 6 SSAKA010JWRE0 Poly bag 1 AA 90 7 TINSEA005FBR0 Operation manual English 1 AN 90 8 SPADPA003FBE0 Plug protector 1 AE 90 9 TGAN A058WRR0 Warning label 1 AF 90 10 TCAUHA008FBR0 Caution label 1 AE 90 11 TSPCNA102FBR0 Name plate 1 AE 90 12 SPADPA002FBE0 Protect sheet 1 AD HOW TO ORDER REPLACEMENT PARTS To have your order filled prompty and corr...

Страница 37: ...28 1 3 2 26 2 4 2 3 1 11 6 8 2 2 4 2 2 27 2 32 6 10 6 6 6 2 6 3 6 7 4 1 2 18 2 8 2 17 2 33 2 35 1 8 2 20 2 22 6 5 6 4 6 9 6 1 2 16 1 10 6 12 6 13 1 7 6 14 2 21 2 19 2 46 2 15 6 11 2 14 2 23 2 24 2 25 2 9 2 36 2 37 2 41 1 12 1 1 2 39 2 42 1 13 2 5 2 30 2 7 2 38 2 40 2 43 2 45 1 14 1 2 1 5 2 44 ...

Страница 38: ...38 DW 71 H ...

Страница 39: ...39 DW 71 H ...

Страница 40: ...40 DW 71 H 96 SHARP CORP YU0 10E Printed in Japan ...

Отзывы: