background image

Содержание CV-P13PX

Страница 1: ...oration Plasmacluster es una marca reg istrada de SHARP Corporation PORTABLE TYPE ROOM AiR CONDITIONER INSTALLATION AND OPERATION MANUAL ACONDICIONADOR DE AIRE PARA HABITACiON TIPO PORTATIL MANUAL DE INSTALACION Y FUNCIONAMIENTO CV P1 CV P1 CV PD1 PX ...

Страница 2: ...AUST HOSE E 18 PRE OPERATION CHECKS E 22 COOL MODE E 24 DEHUMIDIFICATION MODE E 24 FAN MODE E 25 VENTILATION MODE E 25 TO CHANGE AIR FLOW DIRECTION E 26 PLASMACLUSTER OPERATION E 27 MEGA COOL OPERATION E 28 SLEEP OPERATION E 28 TIMER OPERATION E 29 MAIN UNIT OPERATION E 30 DRAINAGE E 30 MAINTENANCE E 31 BEFORE CALLING FOR SERVICE E 32 Declaration of Conformity SHARP ROOM AiR CONDiTiONER CV P12PX C...

Страница 3: ...S for your Authorized Parts Distributor ACCESSORIES ADDITIONAL CUSTOMER INFORMATION TO WRITE For service problems warranty information missing items and other assistance Sharp Electronics Corporation Customer Assistance Center 1300 Naperville Drive Romeoville IL 60446 1091 TO ACCESS THE INTERNET www sharpusa com Please provide the following information when you write or call model number serial nu...

Страница 4: ...omplete fulfillment of all liabilities and responsibilities of Sharp to the purchaser with respect to the Product and shall constitute full satisfaction of all claims whether based on contract negligence strict liability or otherwise In no event shall Sharp be liable or in any way responsible for any damages or defects in the Product which were caused by repairs or attempted repairs performed by a...

Страница 5: ...ord must be replaced with a new power supply cord obtained from the product manufacturer and not repaired Replacement must be performed by manufacture s service agent in order to avoid a hazard NOTE Radio or TV interference If this room air conditioner should cause interference to radio or television reception try to correct the interfer ence by one or more of the following measures Reorient or re...

Страница 6: ... minutes before restarting the unit After power is reinstated restart the air conditioner If the power was off for less than three minutes be sure to wait at least three minutes before restarting the unit If you restart the air conditioner within three minutes a protective device in the unit may cause the compressor to shut off This protective device will prevent cool ing for about 5 minutes Any p...

Страница 7: ... remove the heat produced by your lights or other heat produc ing appliances Turn off any lights or appliances that are not in use Turn off the air conditioner when no one is home Use only when necessary The less time the air conditioner is used the lower the run ning costs The air conditioner should be placed on a firm foundation to minimize noise and vibration For safe and secure positioning pla...

Страница 8: ...pter A Exhaust hose adapter B Bracket aWsis dm _lpanel _ Rain deflector 2 assembly Window slider bracket Foam seal A Foam seal B adhesive type Protective screen Large wood screw Screw Baffle to 0t Washer 2 Bolt 2 Nut 1 Split ring 1 washer Manual 2 Remote control 5 Battery 4 AAA 1 5V C 1 The cover and the grille will be installed in the unit before leaving factory lCove SUGGESTED TOOLS FOR WINDOW P...

Страница 9: ...USTER _ Lamp blue _ Air inlet REAR VIEW CV PD13PX Dual Duct use CV P12PX CV P13PX CV PD13PX Single Duct use _ Exhaust air outlet _ Window exhaust adapter _ Exhaust hose adapter A _ Exhaust hose _ Remote control hook _ Air filter _ Exhaust hose adapter B _ Cover _ Grille _ Air inlet _ Drainpipe and stopcock _ Power plug _ Casters 4 Baffle NOTE Actual unit might vary slightly from above illustration...

Страница 10: ...tton FAN Button OFF TIMER Button CANCEL Button LOUVERS Button RESET Button MEGA COOL Button REMOTE CONTROL DISPLAY MODE SYMBOLS _ COOL DEHUMIDIFICATION _ _ FAN _ VENTILATION MEGA COOL SYMBOL PLASMACLUSTER SYMBOL FAN SPEED SYMBOLS _ AUTO _ Quiet Jm Low Jm_High _ TEMPERATURE AND TIMER COUNT DOWN iNDiCATOR _ TRANSMiTTiNG SYMBOL ON TIMER OFF TIMER SYMBOL _ SLEEP SYMBOL E 9 ...

Страница 11: ...er Install the rain deflector to the outside of the window panel Line up the holes on the rain deflector and the window panel Use 4 bolts 4 washers 4 split ring washers and 4 nuts to attach the rain deflector onto the win dow panel Attach the window panel to the window stool If the inner width of the window is less than 28 718mm wide 1 Remove the adjustment panel from the window panel and cut the ...

Страница 12: ...ndow sash and place the second window panel on the window stool 2 Slide the adjustment panel to fit the window frame width 3 4 Secure the window panel to the window stool with 2 large wood screws Hook the two window slider brackets over the bottom edge of the adjustment panel and attach them to the window stool using 2 large wood screws Cut the foam seal B to the proper length and attach it to the...

Страница 13: ...deflectors to the outside of the window panel Line up the holes on the rain deflector and the window panel Use 8 bolts 8 washers 8 split ring washers and 8 nuts to attach the rain deflector onto the win dow panel Attach the window panel to the window stool If the inner width of the window is less than 28 718mm wide 1 Remove the adjustment panel from the window panel and cut the window panel to the...

Страница 14: ...ash and place the second window panel on the window stool 2 Slide the adjustment panel to fit the window frame width 3 4 Secure the window panel to the window stool with 2 large wood screws Hook the two window slider brackets over the bottom edge of the adjustment panel and attach them to the window stool using 2 large wood screws Cut the foam seal B to the proper length and attach it to the windo...

Страница 15: ...apter Install the rain deflector to the outside of the window panel Line up the holes on the rain deflec tor and the window panel Use 4 bolts 4 washers 4 split ring washers and 4 nuts to attach the rain deflector onto the window panel Install the window panel into the window frame If the inner height of the window is less than 28 718mm high 1 Remove the adjustment panel from the window panel and c...

Страница 16: ...ndow sash and place the window panel on the window frame Slide the adjustment panel to fit the window frame height Secure the window panel to the window frame with 2 large wood screws Hook the two window slider brackets over the bottom edge of the adjustment panel and attach them to the window frame using 2 large wood screws Adjustment panel Window slider bracket Foam seal B 28 N36 5 36 5 N64 Cut ...

Страница 17: ...l 2 rain deflectors to the outside of the window panel Line up the holes on the rain deflec tor and the window panel Use 8 bolts 8 washers 8 split ring washers and 8 nuts to attach the rain deflector onto the window panel Install the window panel into the window frame If the inner height of the window is less than 28 718mm high 1 Remove the adjustment panel from the window panel and cut the window...

Страница 18: ...ow sash and place the window panel on the window frame Slide the adjustment panel to fit the window frame height Secure the window panel to the window frame with 2 large wood screws Hook the two window slider brackets over the bottom edge of the adjustment panel and attach them to the window frame using 2 large wood screws Adjustment panel Window slider bracket Foam seal B 28 N36 5 T 36 5 N64 V Cu...

Страница 19: ...apter B Attach the exhaust hose adapter B to the unit Insert the two projections on the exhaust hose adapter B into the two holes on the unit and firmly attach them to each other Projection Hole Attach the exhaust hose Insert the exhaust hose adapter A to the window exhaust adapter in the window panel and turn it to lock it in place Exhaust hose adapter A Window exhaust adapter The exhaust hose sh...

Страница 20: ...unit by pushing down the two projections on it Insert the two projections on the exhaust hose adapter B into the two holes on the unit and firmly attach them to each other Attach the other exhaust hose adapter B to the unit in the same way _ Cover Projection Hole Attach the exhaust hoses Insert the exhaust hose adapter A to the window exhaust adapter in the window panel and turn it to lock it in p...

Страница 21: ... the grille and the cover to the unit Open the baffle and remove it Insert the 2 projections on the grille into the 2 holes on the back plate of the unit and close the grille Insert the two projections on the cover into the two holes on the unit Hole Projection Grille 7Projection Baffle Install one exhaust hose E 20 ...

Страница 22: ...ove the exhaust hose adapter A from the window exhaust adapter Exhaust hose adapter A Window exhaust adapter Remove the exhaust hose adapter from the unit Lift up and remove the exhaust hose adapter from the unit by pushing down on the two projections Projection E 21 ...

Страница 23: ...AA R03 batteries Remove the battery cover at the back of the remote control insert batteries into the com partment making sure the and _ polarities are correctly aligned Lines will appear on the display when batteries are properly in stalled Reattach the battery cover Battery cover Press the RESET button using a thin pointed implement NOTES The battery should last approximately one year under norm...

Страница 24: ...tains to block out the sunlight Use of a fluorescent lamp in the same room may interfere with transmission of the signal The unit may be affected by signals emitted from other remote controllers for tel evisions VCRs or other equipment used in the same room Do not leave the remote control exposed to direct sunlight or near a heater Pro tect the remote control from moisture and shock which can disc...

Страница 25: ... F Press the FAN button to set the desired fan speed AUTO QUIET LOW HIGH ITO TURN OFF Press the POWER button again The red OPERATION lamp on the unit will turn off in this mode the air conditioner dehumidifies the room Ensure that the stopcock is securely attached the drainpipe 1 1 Press the MODE button to select DEHU MIDIFICATION mode COOL DEHUM FAN VENT Press the power button to start operation ...

Страница 26: ...red OPERATION lamp on the unit will turn off B in this mode the air conditioner ventilates the air to outdoors Ensure that the stopcock is securely attached the drainpipe 2 1 3 O SLEEP Press the MODE button to select VENT mode COOL DEHUM FAN VENT Press the POWER button to start operation The red OPERATION lamp on the unit will light The temperature cannot be set Press the FAN button to set the des...

Страница 27: ...VENTILATION mode UP DOWN air flow direction cannot be changed Horizontal louvers Hold the vertical louver as shown in the dia gram and adjust the air flow direction louvers CAUTION Never attempt to adjust the horizontal louvers manually Manual adjustment of the horizontal louvers can cause the unit to malfunction when the remote control is used for adjustment When the horizontal louvers are positi...

Страница 28: ...l display _on e The blue PLASMAOLUSTER lamp on the unit will light I TO CANCEL 1 Press the PLASMACLUSTER button again The PLASMACLUSTER lamp on the unit will turn off NOTES Use of the PLASMACLUSTER function will be memorized and it will be activated the next time you turn on the air conditioner To turn off the PLASMACLUSTER Lamp press the LIGHTS button PLASMACLUSTER operation cannot be set during ...

Страница 29: ...ion is set the temperature setting is automatically adjusted to revent the room from becoming too cold 1 1 Press the SLEEP button during cooling mode The remote control displays _ The orange TIMER lamp on the unit will light The unit will stop operating after 8 hours The fan speed setting is set to AUTO 1 Press the SLEEP button NOTES One hour after the SLEEP operation is started the temperature se...

Страница 30: ...CANCEL 1 1Press the OFF TIMER button and set the time as desired The time setting will change as you press the button as follows Hold the button down to speed through the settings 0 5h _1 0h _l 5h _10h _11 h _12h L J The orange TIMER lamp on the unit will light The time setting will count down to show the remain ing time I TO CANCEL TIMER I Press the CANCEL button The orange TIMER lamp on the unit...

Страница 31: ...The fan speed set to AUTO ITO TURN OFF Press the POWER button again The red OPERATION lamp on the unit will turn off Prepare for drainage and drain out water within the unit in the following cases When the unit stops operating and the TIMER OPERATION and MEGA COOL lamps are blinking the water tank is full and need to be drained When the unit is not used for a long time Unplug the power plug and mo...

Страница 32: ... the unit without the filter Doing so may result in serious damage to the unit AIR INLET FILTER JFor sinqle duct t_vp_e_L Remove the grille and clean the air inlet filter with a vacuum cleaner CLEANING THE UNIT AND THE REMOTE CONTROL Wipe them with a soft dry cloth or with a cloth moistened with a mild soap Carefully remove any residue by wiping with a damp cloth and dry completely Avoid splashing...

Страница 33: ...le The exhaust hose must not be twisted or bent SOUNDS The unit may seem rather loud for the first 2 to 3 minutes when the unit is turned on This is the sound of the compressor starting up and is perfectly normal A soft swishing noise can be heard immediately after the unit is turned on or off and also during operation This is the sound of the refrigerant flowing inside the unit A low buzzing nois...

Отзывы: