PORTABLE TYPE
ROOM AIR CONDITIONERINSTALLATION AND OPERATION
MANUAL
H
SI
L
G
N
E
O
Ñ
AP
S
CV-P10LJ CV-P13LJ
Страница 1: ...PORTABLE TYPE ROOM AIR CONDITIONER INSTALLATION AND OPERATION MANUAL H S I L G N E L O Ñ A P S E CV P10LJ CV P13LJ ...
Страница 2: ... LOCATION E 3 INCLUDED E 4 PART NAMES E 5 INSTALL WINDOW PANEL E 7 INSTALLATION AND REMOVAL OF EXHAUST HOSE E 11 PRE OPERATION CHECKS E 13 COOL MODE E 15 DEHUMIDIFICATION MODE E 15 FAN MODE E 16 VENTILATION MODE E 16 TO CHANGE AIR FLOW DIRECTION E 17 PLASMACLUSTER OPERATION E 18 MEGA COOL OPERATION E 19 SLEEP OPERATION E 19 TIMER OPERATION E 20 MAIN UNIT OPERATION E 21 DRAINAGE E 22 MAINTENANCE E ...
Страница 3: ...uring use allow 3 minutes before restarting the unit After power is reinstated restart the air conditioner If the power was off for less than three minutes be sure to wait at least three minutes before restarting the unit If you restart the air conditioner within three minutes a protective device in the unit may cause the compressor to shut off This protective device will prevent cool ing for abou...
Страница 4: ...ts Your air conditioner must remove the heat produced by your lights or other heat produc ing appliances Turn off any lights or appliances that are not in use Turn off the air conditioner when no one is home Use only when necessary The less time the air conditioner is used the lower the run ning costs LOCATION The air conditioner should be placed on a firm foundation to minimize noise and vibration...
Страница 5: ...adhesive type 1 Bracket Manual 1 3 Remote control 1 Screw 8 Battery AAA 1 5V 2 E 4 INCLUDED SUGGESTED TOOLS FOR WINDOW PANEL INSTALLATION 1 Screwdriver medium size Phillips 2 Tape measure or ruler 3 Knife or scissors 4 Saw In the event that the window panel needs to be cut down in size because the window is too narrow for direct installation ...
Страница 6: ...9 PLASMACLUSTER Lamp blue 0 Air inlet REAR VIEW NOTE Actual unit might vary slightly from above illustration FRONT VIEW q Insect guard net w Window exhaust adapter e Remote control hook r Exhaust hose t Remote control hook y Air filter u Exhaust hose adapter B i Cover o Grille p Airinlet a Drainpipe and stopcock s Power plug Casters 4 E 5 1 2 3 4 5 6 7 8 9 0 0 q w e r t y u i o p a s ...
Страница 7: ...R Button w CANCEL Button e LOUVERS Button r RESET Button t MEGA COOL Button E 6 y MODE SYMBOLS COOL DEHUMIDIFICATION FAN VENTILATION u MEGA COOL SYMBOL i PLASMACLUSTER SYMBOL o FAN SPEED SYMBOLS AUTO Quiet Low High p TEMPERATURE AND TIMER COUNT DOWN INDICATOR a TRANSMITTING SYMBOL s ON TIMER OFF TIMER SYMBOL d SLEEP SYMBOL REMOTE CONTROL DISPLAY 1 2 3 4 5 6 7 8 9 0 q w e r t y u i o p a s d ...
Страница 8: ...re that its four projections fit into the holes in the window panel Side A will now be at the top as indicated in the diagram 3 Cut the foam seal A adhesive type to the proper length and attach it to the window stool 4 Attach the window panel to the window stool If the inner width of the window is be tween 22 559mm and 24 609mm inclusive The window panel cannot be installed in windows less than 22...
Страница 9: ... 2 Open the window sash and place the window panel on the window stool 3 Slide the adjustment and extension panels to fit the window frame width 4 Secure the window panel to the window stool with 4 screws 5 Cut the foam seals adhesive type A and B to the proper length and attach it to the window panel Attach foam seal A to the window panel and extension panel and attach foam seal B to the adjustme...
Страница 10: ...Side A will now be at the top as indicated in the diagram when it is installed in the window 3 Cut the foam seal A adhesive type to the proper length and attach it to the window frame 4 Install the window panel into the window frame If the inner height of the window is between 22 559mm and 24 609mm inclusive The window panel cannot be installed in windows less than 22 559mm high as you will be una...
Страница 11: ...dow frame 3 Slide the adjustment and extension panels to fit the window frame height 4 Secure the window panel to the window frame with 4 screws 5 Cut the foam seals adhesive type A and B to the proper length and attach them to the window panel Attach foam seal A to the window panel and extension panel and attach foam seal B to the adjustment panel 6 Close the window sash securely against the Wind...
Страница 12: ...attached afterwards 2 Attach the exhaust hose adapter to the unit Insert the two projections on the ex haust hose adapter into the two holes on the unit and firmly attach them to each other 3 Slide and open the exhaust cover on the window panel and attach the win dow exhaust adapter Surface of window exhaust adapter marked TOP should be at the top when it is installed in a double hung sash window ...
Страница 13: ...r Pull out and remove the window exhaust adapter by pushing down two PUSH markings and slide and close the exhaust cover in the window panel 2 Remove the exhaust hose adapter from the unit Lift up and remove the exhaust hose adapter from the unit by pushing down on the two projections ...
Страница 14: ...ted implement If you will not be using the unit for a prolonged period remove the batteries from the remote control LOADING BATTERIES Use two AAA R03 batteries Battery cover PRE OPERATION CHECKS 1 Remove the battery cover at the back of the remote control 2 Insert batteries into the com partment making sure the and polarities are correctly aligned Lines will appear on the display when batteries ar...
Страница 15: ...sed to direct sunlight or near a heater Pro tect the remote control from moisture and shock which can discolor or damage it Point the remote control towards the units signal receiver window and press the desired button A beep will sound when the unit re ceives the signal Make sure nothing such as curtains blocks the signal receiver window The remote control operates up to 23 feet 7 meters away HOW...
Страница 16: ...IET LOW HIGH TO TURN OFF Press the POWER button again The red OPERATION lamp on the unit will turn off Stopcock Drainpipe DEHUMIDIFICATION MODE In this mode the air conditioner dehumidifies the room Ensure that the stopcock is securely attached the drainpipe 1Press the MODE button to select DEHU MIDIFICATION mode COOL DEHUM FAN VENT 2Press the power button to start operation The red OPERATION lamp ...
Страница 17: ...ss the POWER button again The red OPERATION lamp on the unit will turn off 1 Press the MODE button to select VENT mode COOL DEHUM FAN VENT 2 Press the POWER button to start operation The red OPERATION lamp on the unit will light The temperature cannot be set 3 Press the FAN button to set the desired fan speed Although the louvers are closed and no air blows out into the room the external ventilati...
Страница 18: ... and the same position will be set automatically when operated the next time LEFT RIGHT AIR FLOW DIRECTION CAUTION Never attempt to adjust the horizontal louvers manually Manual adjustment of the horizontal louvers can cause the unit to malfunction when the remote control is used for adjustment When the horizontal louvers are positioned at the lowest position in the COOL or DEHUMIDIFI CATION mode ...
Страница 19: ...e PLASMACLUSTER lamp on the unit will turn off NOTES Use of the PLASMACLUSTER function will be memorized and it will be activated the next time you turn on the air conditioner To turn off the PLASMACLUSTER Lamp press the LIGHTS button PLASMACLUSTER operation cannot be set during VENTILATION mode PLASMACLUSTER OPERATION Plasmacluster ions released into the room will reduce some airborne mold 1 ...
Страница 20: ...n is set the temperature setting is automatically adjusted to prevent the room from becoming too cold SLEEP OPERATION 1 Press the SLEEP button during cooling mode The remote control displays The orange TIMER lamp on the unit will light The unit will stop operating after 8 hours The fan speed setting is set to AUTO TO CANCEL Press the SLEEP button The orange TIMER lamp on the unit will turn off SLE...
Страница 21: ...r to a maximum of 12 hours Up to 9 5 hours you can set in half hour increments and from 10 to 12 hours in 1 hour increments The latest time setting will be memorized and will appear on the remote control display the next time you set the OFF TIMER or ON TIMER The OFF TIMER and ON TIMER can not be set together Only the most recent TIMER setting will be valid If a power failure occurs while the OFF ...
Страница 22: ...n the unit 3 Replace the stopcock to the drainpipe MAIN UNIT OPERATION DRAINAGE 1 E 21 Use this mode when the remote control is not available 1 Press the POWER button on the unit The red OPERATION lamp on the unit will light If the unit has not been unplugged since it was last operated it will resume operation at its last settings If the unit has been unplugged since it was last operated it will r...
Страница 23: ...er from the wall socket before performing any mainte nance CLEANING THE FILTER MAINTENANCE AFTER AIR CONDITIONER SEASON Air inlet filter Air filter Grille If the filter is clogged with dust the airflow will be reduced resulting in poor cooling performance The filter should be cleaned every two weeks AIR FILTER 1 REMOVE THE FILTER Gently pull the filter handle to the right and slide the filter out of the...
Страница 24: ...ible The exhaust hose must not be twisted or bent SOUNDS The unit may seem rather loud for the first 2 to 3 minutes when the unit is turned on This is the sound of the compressor starting up and is perfectly normal A soft swishing noise can be heard immediately after the unit is turned on or off and also during operation This is the sound of the refrigerant flowing inside the unit A low buzzing nois...
Страница 25: ...14 20 12 Climate Type T1 13 Isolation I 14 Moisture Protection IP24 15 Permissible Excessive Operating Pressure for the Discharge Side MPa 3 8 16 Permissible Excessive Operating Pressure for the Suction Side MPa 1 17 Throttling Method Capillary 18 Fuse A 3 15 19 Operation Temp 16ºC 30ºC 20 Ambient Temp Cooling 10ºC 35ºC 21 Sound Pressure Level H M L dB A 56 54 52 22 Sound Power Level H M L dB A 66...
Страница 26: ...Fan Motor W 40 41 Fan Motor RLA A 0 46 42 Fan Motor Capacitor μF 3 5 43 Form Aluminum Fin copper Tube 44 Pipe Diameter mm φ7 45 Row fin Gap mm 3 1 6 46 Coil Length LXDXW mm 348 5 X38 1X286 47 Swing Motor Model MP28GA 48 Evaporator Output of Swing Motor W 2 49 Fan Type Centrifugal 50 Fan Diameter mm φ227 X 109 51 Form Aluminum Fin copper Tube 52 Pipe Diameter mm φ7 53 Rows fin Gap mm 3 1 6 54 Coil ...
Страница 27: ...18 24 12 Climate Type T1 13 Isolation I 14 Moisture Protection IP24 15 Permissible Excessive Operating Pressure for the Discharge Side MPa 3 8 16 Permissible Excessive Operating Pressure for the Suction Side MPa 1 17 Throttling Method Capillary 18 Fuse A 3 15 19 Operation Temp 16ºC 30ºC 20 Ambient Temp Cooling 10ºC 35ºC 21 Sound Pressure Level H M L dB A 57 55 53 22 Sound Power Level H M L dB A 67...
Страница 28: ...of Fan Motor W 40 41 Fan Motor RLA A 0 46 42 Fan Motor Capacitor μF 3 5 43 Form Aluminum Fin copper Tube 44 Pipe Diameter mm φ7 45 Row fin Gap mm 3 1 6 46 Coil Length LXDXW mm 348 5 X38 1X286 47 Swing Motor Model MP28GA 48 Evaporator Output of Swing Motor W 2 49 Fan Type Centrifugal 50 Fan Diameter mm φ227 X 109 51 Form Aluminum Fin copper Tube 52 Pipe Diameter mm φ7 53 Rows fin Gap mm 4 1 6 54 Co...
Страница 29: ...uid spillage vermin infestation software or any alterations made to the product which are not authorised by Sharp Please retain your sales documentation as this should be produced to validate a warranty claim This warranty is in addition to and in no way limits varies or excludes any express and implied rights and remedies under any relevant legislation in the country of sale For your reference pl...
Страница 30: ...09 573 0113 FOR LOCATION ENQUIRIES WITHIN AUSTRALIA REGARDING YOUR LOCAL SHARP APPROVED SERVICE CENTRE VISIT OUR WEBSITE AT www sharp net au OR CALL SHARP CUSTOMER CARE 1300 135 022 SHARP CORPORATION OF AUSTRALIA PTY LTD SPform019 FEB 2010 LOCAL CALL COST APPLY WITHIN AUSTRALIA SHARP APPROVED SERVICE CENTRE www sharp net nz CONTACT YOUR SELLING DEALER RETAILER OR CALL SHARP SHARP ...