CVP09FX
2 – 6
3. Fan mode
4. Ventilation mode
5. To change air flow direction
6. Plasmacluster operation
7. Mega cool operation
8. One-hour off timer
1
5
2
3
Install the exhaust hose (See Page16), turn the drainage nozzle to the CLOSE
position, and check the drainage nozzle is covered with the stopcock.
1
3
2
In this mode, the air conditioner simply circulates the air without cooling it.
1
Press the MODE button to select FAN mode.
COOL
DEHUM
FAN
VENT
2
Press the POWER button to start operation.
• The red OPERATION lamp on the unit will light.
• The temperature cannot be set.
3
Press the FAN button to set the desired fan
speed.
QUIET
LOW
HIGH
TO TURN OFF
Press the POWER button again.
• The red OPERATION lamp on the unit will turn off.
1
4
5
2
3
Install the exhaust hose (See Page 16), turn the drainage nozzle to the CLOSE
position, and check the drainage nozzle is covered with the stopcock.
1
3
2
In this mode, the air conditioner ventilates the air to outdoors.
1
Press the MODE button to select VENT mode.
COOL
DEHUM
FAN
VENT
2
Press the POWER button to start operation.
• The red OPERATION lamp on the unit will light.
• The temperature cannot be set.
3
Press the FAN button to set the desired fan
speed.
• Although the louvers are closed and no air blows
out into the room, the external ventilation fan speed
changes.
QUIET
LOW
HIGH
TO TURN OFF
Press the POWER button again.
• The red OPERATION lamp on the unit will turn off.
UP / DOWN AIR FLOW DIRECTION
NOTE
• During VENTILATION mode, UP/DOWN air flow
direction cannot be changed.
Hold the vertical louver as shown in the dia-
gram and adjust the air flow direction.
1
Press the LOUVERS button on the re-
mote control.
• The horizontal louvers will swing continuously.
2
Press the LOUVERS button again when
the horizontal louvers are at the desired
position.
• The horizontal louvers will stop moving.
• The adjusted position will be memorized and
the same position will be set automatically
when operated the next time.
LEFT / RIGHT AIR FLOW DIRECTION
CAUTION
Never attempt to adjust the horizontal louvers manually.
• Manual adjustment of the horizontal louvers can cause the unit to malfunction when the remote
control is used for adjustment.
• When the horizontal louvers are positioned at the lowest position in the COOL or DEHUMIDIFICA-
TION mode for an extended period of time, condensation may result.
Do not adjust the vertical louvers to the extreme left or right in the COOL mode with the fan
speed set to "QUIET (
)" for an extended period of time.
Condensation may form on the louvers.
Horizontal louvers
Vertical louvers
1
2
1
Press the PLASMACLUSTER button during
operation.
• The remote control will display “
”.
• The blue PLASMACLUSTER lamp on the unit will
light.
TO CANCEL
Press the PLASMACLUSTER button again.
• The PLASMACLUSTER lamp on the unit will turn off.
NOTES:
• Use of the PLASMACLUSTER function will be memo-
rized and it will be activated the next time you turn on
the air conditioner.
• To turn off the PLASMACLUSTER Lamp, press the
LIGHTS button.
• PLASMACLUSTER operation cannot be set during
VENTILATION mode.
The Plasmacluster ion generator inside the air conditioner will release positive and
negative Plasmacluster ions into the room. Approximately the same numbers of posi-
tive and negative ions released into the air.
1
1
Press the MEGA COOL button during cooling
mode.
• The remote control will display "
" .
• The temperature display will go off.
• The green MEGA COOL lamp on the unit will light.
TO CANCEL
Press the MEGA COOL button again.
• MEGA COOL operation is also cancelled when the
mode is changed, or when the unit is turned off.
• The green MEGA COOL lamp on the unit will turn off.
In this operation, the air conditioner fan works at extra high speed with a setting
temperature of 59°F.
1
NOTES:
• You cannot set the temperature or fan speed during MEGA COOL operation.
• The fan returns to the HIGH speed setting after the unit has run for 30 minutes in MEGA
COOL mode.
• The extra high fan speed may automatically slow down to protect the unit.
1
Press the 1hr OFF button.
• The remote control displays “
”.
• The orange TIMER lamp on the unit will light.
• The unit will stop operating after one hour.
TO CANCEL
Press the CANCEL button.
• The orange TIMER lamp on the unit will turn off.
Alernatively, turn the unit off by pressing the
POWER button.
• The red OPERATION lamp and the orange TIMER
lamp on the unit will turn off.
1
When the ONE-HOUR OFF TIMER is set, the unit will automatically turn off after one
hour.
NOTES:
• The ONE-HOUR OFF TIMER operation has priority over ON TIMER and OFF TIMER
operations.
• If the ONE-HOUR OFF TIMER is set while the unit is not operating, the unit will operate for
an hour at the formerly set condition.
• If you wish to operate the unit for another hour before the ONE-HOUR OFF TIMER is
activated, press the 1hr OFF TIMER button again during operation.
CANCEL