XL-MP130
6 – 16
Figure 6-16 WIRING SIDE OF PWB (5/9)
A
B
C
D
E
F
G
H
1
2
3
4
5
6
IC854
R841
D856
D853
C861
R844
CNP802
R801
C842
ZD801
R805
R802
C807
D803
C806
R858
D804
C841
C803
D806
ZD802
D805
C805
D843
D842
D844
D845
C804
C843
R842
Q841
R843
R890
PT841
D846
RL841
F805
F801
F803
F804
F802
C844
C808
D802
C810
C809
R806
R808
R807
Q801
ZD803
C801
D801
R803
R804
C802
C811
CNP801
PT801
B
E
C
B
C
E
B R
COLOR TABLE
R D ( R )
O R
Y L
G R
B L
V L
G Y
W H ( W )
B K
P K
BROWN
RED
ORANGE
YELLOW
GREEN
BLUE
VIOLET
GRAY
WHITE
BLACK
PINK
POWER PWB-B1
4A
125V
4A
125V
2A
125V
2A
125V
4A 125V
6-13 12 - E
FROM MAIN PWB
CNS802
6-13 12 - F
FROM MAIN PWB
CNS801
1
10
9
8
7
6
5
4
3
2
1
1
2 3 4 5 6
2
3
POWER
TRANSFORMER
(SUB)
12
34
98
7
6
5
RELAY
T.F.
1
BK
WH
2
3
4
5
6
7
POWER
TRANSFORMER
(MAIN)
8
9
10
11
12
13
14
15
16
17
AC POWER
SUPPLY CORD
(225)
AC 120 V, 60 Hz
6-13 9 - B
TO MAIN P
CNP101
Lead-free solder indication
Lead-free solder is used in the POWER PWB.
Refer to "Precautions for handling lead-free solder" for instructions
and precautions.
Содержание CP-MP130