Sharp CMS-R600X Скачать руководство пользователя страница 5

CMS-R600X/R600XT

OPERATION MANUAL

S

E

TTI

NG

 THE

 CLO

CK 

Setting method when the POWER switch is in the STAND-BY

position.

1

Press the MEMORY/SET button.

W

hen t

h

e

 po

w

e

is

 O

N

pr

ess

 t

he 

C

L

O

C

K

/TI

M

E

R

 

but

to

n

.

Then, within 5 seconds, press the MEMORY/SET button.

2

Press 

the 

PRESET/TIME 

(

 or 

) button to select the time

display.

PRESET/

TIME (         )

CLOCK/

TIMER

MEMORY/

SET

1

2

AM   0:00

AM   12:00

0:00

3

4

5

6

7

"0:00" 

     →

  Th

e 2

4

-h

ou

r dis

pl

ay

 w

ill a

p

p

e

a

r. 

                 (

0

:0

0

 -

 2

3

:5

9

)

"A

M

 0:

00

"  

 T

h

e 1

2

-h

ou

r di

sp

la

y

 w

ill

 ap

pe

ar

.

                 (

A

M

 0

:0

0

 -

 P

M

 1

1

:5

9

)

"AM 12:00" 

 The 12-hour display will appear.

                 (

A

M

 1

2

:0

0

 -

 P

M

 1

1

:5

9

)

3

Press the MEMORY/SET button.

4

Press 

the 

PRESET/TIME 

(

 or 

) button to adjust the hour.

Press the PRESET/TIME button once to advance the time by

1 hour. Press for more than 0.5 seconds to advance continu

-

ously.

When the 12-hour display is selected, "AM" will change auto

-

matically to "PM".

5

Press the MEMORY/SET button.

6

P

re

s

s

 t

h

e

 P

R

E

S

E

T

/TI

M

E

 (

 

o

) b

u

tto

n

 

to

 a

d

ju

s

th

e

minutes.

Press the button for at least 0.5 seconds to advance continu

-

ously.

The hour setting will not advance even if minutes advance

from "59" to "00".

7

Press the MEMORY/SET button.

The clock starts operating from "0" seconds. (Seconds are

not displayed.)

Note:

In the event of a power failure or when the AC power lead

is disconnected, the clock display will go out.

When the AC power supply is resumed, the clock display will

flash on and off to indicate that the time must be reset.

If this happens, follow steps 1 and 4 - 7 in the procedure

described above.

To change the clock time:

1

Whilst the clock is displayed, press the MEMORY/SET button.

When t

he pow

er

 

is O

N

pr

es

the C

L

O

C

K

/TI

M

E

R

 but

to

n.

Then, within 5 seconds, press the MEMORY/SET button.

2

Perform steps 4 - 7 above.

To see the time display: (When the power is ON)

Press the CLOCK/TIMER button.

The time display will appear for about 5 seconds.

To switch the time display mode:

1

Set the POWER switch to STAND-BY.

2

Whi

lst

 holding

 

do

w

n

 

the C

L

O

C

K

/TI

M

E

R

 but

to

n

, pr

ess t

h

e

POWER switch twice.

3

Perform steps 1 - 7 above.

In this example, the clock is set for the 24-hour

(0:00) system.

15

15

Notes concerning use:

Replace the batteries if control distance decreases or oper

-

ation becomes erratic.

Periodically clean the transmitter LED on the remote control

and the sensor on the main unit with a soft cloth.

Exposing the sensor on the main unit to strong light may in

-

terfere with operation. Change the lighting or the direction of

the unit.

Keep the remote control away from moisture, excessive heat,

shock, and vibrations.

0.2 m - 6 m

(8" - 20')

P

R

E

P

ARA

TI

O

N

 FO

R US

E

RE

S

E

TTI

NG

 THE

 MI

CRO

CO

MP

UTE

R

Reset the microcomputer by performing the following

procedure for the cases shown below:

To erase all of the stored memory contents, or

If the display does not function properly, or

The unit does not operate properly.

1

Set the POWER switch to STAND-BY.

2

Disconnect the AC power lead from the AC socket.

3

Press the RESET button for at least 3 seconds.

RESET

– 5 –

Содержание CMS-R600X

Страница 1: ...fied should be used CMS R600X BK CMS R600XT BK Illustration CMS R600X BK Page SPECIFICATIONS 2 VOLTAGE SELECTION 2 NAMES OF PARTS 3 OPERATION MANUAL 5 DISASSEMBLY 6 REMOVING AND REINSTALLING THE MAIN PARTS 8 ADJUSTMENT 10 NOTES ON SCHEMATIC DIAGRAM 12 TYPES OF TRANSISTOR AND LED 12 BLOCK DIAGRAM 13 SCHEMATIC DIAGRAM WIRING SIDE OF P W BOARD 16 WAVEFORMS OF CD CIRCUIT 36 LCD DISPLAY 37 TROUBLESHOOT...

Страница 2: ...layback x 1 Erase x 1 Compact disc player section Type 5 disc multi play compact disc player Signal readout Non contact semiconductor laser Rotational speed 200 500 rpm CLV Approx Error correction CIRC Cross Interleave Reed Solomon Code Quantization 16 bit linear Filter 4 times oversampling digital filter D A Converter 1 bit D A converter Frequency response 20 20 000 Hz Dynamic range 90 dB 1 kHz W...

Страница 3: ...o Mode Indicator ST 23 FM Stereo Indicator 24 Equalizer Mode Buttons 25 Extra Bass Button X BASS 26 Function Selector Buttons 27 Volume Up Down Buttons 28 Editing Speed Selector Buttons 29 CD Pause Button 30 Record Pause Button 31 CD TAPE Stop Button 32 CD Track Down Review Button TAPE Rewind Button 33 CD Track Up Cue Button TAPE Fast Forward Button 34 CD Play Repeat Button TAPE Play Button 35 Mem...

Страница 4: ... Down Review Button 5 Disc Skip Button 6 Pause Button 7 Random Button 8 Play Repaet Button 9 Stop Button 10 Memory Button 11 Track Up Cue Button 12 Clear Button Tape Control Section 13 TAPE 1 Stop Button 14 TAPE 1 Play Button 15 TAPE 2 Rewind Button 16 TAPE 2 Fast Forward Button 17 TAPE 2 Stop Button 18 TAPE 2 Play Button 19 TAPE 2 Record Pause Button Tuner control section 20 Band Selector Button ...

Страница 5: ...off to indicate that the time must be reset If this happens follow steps 1 and 4 7 in the procedure described above To change the clock time 1 Whilst the clock is displayed press the MEMORY SET button When the power is ON press the CLOCK TIMER button Then within 5 seconds press the MEMORY SET button 2 Perform steps 4 7 above To see the time display When the power is ON Press the CLOCK TIMER button...

Отзывы: