![Sharp CD-MPS700 Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/sharp/cd-mps700/cd-mps700_service-manual_372882008.webp)
CD-MPS700
2 – 4
[4] CD section
CD Error code description
* 'CHECKING'
If Error is detected, 'CHECKING' will be displayed instead of 'ER-
CD**'. 'ER-CD**' display will only be displayed when error had been
detected for the 5th times.
Standard Specification of Stereo System Error Message Display Contents
(*) CHECKING:
If CD changer mechanism error is detected, 'CHECKING' will be dis-
play instead of 'ER-CD**'. 'ER-CD**' display will only be display when
error had been detected for the 5 th times.
Speaker abnormal detection and +B PROTECTION display
In case speaker abnormal detection or +B PROTECTION had
occurred, it can be check by pressing 'POWER', '
' and 'X-BASS'
button. MicroComputer version number will displayed as "XM******".
Press ‘GAME/VIDEO’ button during version number display and then
press ‘POWER’, ‘MEMORY/SET’ and ‘GAME/VIDEO’ button. Display
will show "S** B**". S is referring to speaker abnormal detection and B
is referring to +B PROTECTION. ** is in hex valve.
+B PROTECTION is condition when irregular process occur on power
supply line.
BEFORE TRANSPORTING THE UNIT
The following process need to be taken after set tapering/parts
replacement.
1. Press the ON/STAND-BY button to enter stand-by mode.
2. While pressing down the
button and the X-BASS/DEMO but-
ton, press the ON/STAND-BY button. The Micro Computer version
number will be displayed as "XM******".
3. Press OPEN/CLOSE button until "WAIT"
→
"FINISHED" appears.
4. Unplug the AC cord and the unit is ready for transporting.
Error
Explanation
01
When Pickup set inner position, inner switch cannot detect
'ON' level for 10 secs.
10*
CAM error. Can't detect CAM switch when CAM is moving.
11*
When it detect cam operation error during initialize pro-
cess.
20*
TRAY error. Can't detect TRAY switch when TRAY is mov-
ing.
21*
When it detect TRAY operation error during initialize pro-
cess.
31
When it change to CD function, DSP cannot read initial
data.
Error Contents
Display
Notes
CD
Pickup Mechanism Error.
'ER-CD01'
PU-IN SW Detection NG.
CD Changer Mechanism Error.
'ER-CD**' (*)
10: CAM SW Detection NG during normal operation
11: CAM SW Detection NG during initialize process
20:TRAY SW Detection NG during normal operation
21:TRAY SW Detection NG during initialize process
CD DSP Communication Error.
'ER-CD31'
DSP COMMUNICATION ERROR.
Focus Not Match/IL Time Over.
'NO DISC'
TUNER
PLL Unlock.
PLL Unlock.
FM 87.5 MHz
Содержание CD-MPS700
Страница 11: ...CD MPS700 2 7 APPLY GREASE PULL THE LEVER UNITIL REACH THE ARROW MARK 143 112 3 ...
Страница 12: ...CD MPS700 2 8 FIGURE 1 FIGURE 2 APPLY GREASE SLOT CLAMP SW ARM INSIDE BASE SLOT 152 142 118 4 ...
Страница 14: ...CD MPS700 2 10 APPLY GREASE AT HALF GEAR AREA ROTATE CLOCKWISE UNTIL REACH HERE MAXIMUM 6 129 ...
Страница 15: ...CD MPS700 2 11 CHANGE COLOR TO BLACK 150 151 148 7 ...
Страница 18: ...CD MPS700 2 14 10 148 147 146 145 ...
Страница 19: ...CD MPS700 2 15 APPLY GREASE WHEN FIXING ITEM 2 MUST FOLLOW AS SHOWN 121 144 130 11 ...
Страница 20: ...CD MPS700 2 16 FIGURE 1 FIGURE 3 FIGURE 2 APPLY GREASE SC141 APPLY GREASE 117 12 ...
Страница 23: ...CD MPS700 2 19 APPLY GREASE BEHIND THE LEVER NEED TO APPLY GREASE PULL IT THEN LEVER WILL MOVE IN 115 15 ...
Страница 28: ...CD MPS700 2 24 BIG SLOT FACING OUT 110 20 ...
Страница 32: ...CD MPS700 2 28 804 24 SCREW TORQUE 3 kgf cm 0 5 0 ...
Страница 40: ...CD MPS700 2 36 NO GAP HAVE GAP O K N G 32 ...
Страница 47: ...CD MPS700 3 7 MEMO ...
Страница 55: ...CD MPS700 5 4 MEMO ...
Страница 100: ...CD MPS700 14 11 CD MECHANISM PARTS 701 304 701 302 301 NM1 703x2 305x2 NSW1 NM2 308 PWB F 306 2 306 704 307 306 1 306 3 ...