STEP 1 - CABINET OR WALL OPENING 

Provide  an  opening  in  the  wall  or  cabinet  as  indicated 
in  Figure  1.  The  depth  should  be  a  minimum  of  20 

1

/

8

(511.2 mm). If the Depth (E) dimension is greater than 21" 
(533.4 mm), the outlet location may be in any area on the 
rear wall. The floor of the opening should be constructed of 
plywood strong enough to support the weight of the oven 
(approximately 100 lbs/45 kg) and should be level for proper 
operation of the oven.

NOTE:

  While  the  proper  function  of  the  oven  does  not 

require that the opening be enclosed (with sides, ceiling and 
rear  partition),  this  may  be  required  by  local  code,  and  it 
is suggested that the local code be checked for any such 
requirement.
The  opening  in  the  wall  or  cabinet  must  be  within  the 
following dimensions, centered horizontal to the cabinet.

RK94S27F

RK94S30F

A

20" (508 mm)

20" (508 mm)

B

26 

7

/

8

" (682.6 mm)

29 

7

/

8

" (758.8 mm)

C

18 

1

/

2

" (470 mm)

18 

1

/

2

" (470 mm)

25 

1

/

4

" (641.3 mm)

25 

1

/

4

" (641.3 mm)

E

Min. 20 

1

/

8

" (511.2 mm)

Min. 20 

1

/

8

" (511.2 mm)

F

5" (127 mm)

5" (127 mm)

G

10" (254 mm)

10" (254 mm)

Outlet should 

NOT

 be in the shaded area as indicated on 

Figure 1.

NOTE:

•  If the dimension of DEPTH (E) is more than 21" (533.4 mm), 

the outlet location may be any area on the rear wall.

D

C

34-1/2” MIN.

FLOOR

FLOOR

A

B

G

F

E

FIGURE 1

STANDARD INSTALLATION INSTRUCTIONS

STEP 2 - EXHAUST DUCT ASSEMBLY INSTALLATION

A. Insert the edge of DUCT (B) into the hold lip of DUCT (C). 

Secure together by using a SCREW (I) provided in the kit. 
See Figure 2.

DUCT (C)

DUCT (B)

SCREW (I)

FIGURE 2

B. Position  DUCT  (A)-1  on  the  top  of  the  oven  inserting 

edge of DUCT (BC) assembly into hole lip of DUCT (A)-
1. Tighten 2 SCREWS (I), securing DUCT (A)-1 to DUCT 
(BC) assembly. See Figure 3.

SCREW (I)

DUCT (A)-1

DUCT (BC)

SCREW (I)

FIGURE 3

C. Position DUCT (A)-2 on the top of the oven and insert it 

into  the  hold  lip  of  DUCT  (A)-1.  Secure  DUCT  (A)-2  to 
DUCT (A)-1 using 2 SCREWS (I) provided.  See Figure 4.

SCREW (I)

SCREW (I)

DUCT (A)-2

DUCT (A)-1

FIGURE 4

NOTE:

 Floor of opening 

should be 90˚ to front 
cabinet frame.

Содержание Carousel RK94S27F

Страница 1: ...efore installing the Built in Kit Remove the Carousel turntable from the oven cavity Because the kit includes metal parts due caution should be used in handling and installation to avoid the possibility of injury ITEM PART NAME QTY A DUCT A 1 PDUC 0259WRW0 1 B DUCT A 2 PDUC B127MRP0 1 C DUCT A 3 PDUC A734WRW0 1 D DUCT B PDUC 0260WRW0 1 E DUCT C PDUC A274WRW0 1 F BOTTOM DUCT ASSEMBLY FDUC B099MRK1A...

Страница 2: ... C 181 2 470 mm 181 2 470 mm D 251 4 641 3 mm 251 4 641 3 mm E Min 201 8 511 2 mm Min 201 8 511 2 mm F 5 127 mm 5 127 mm G 10 254 mm 10 254 mm Outlet should NOT be in the shaded area as indicated on Figure 1 NOTE If the dimension of DEPTH E is more than 21 533 4 mm the outlet location may be any area on the rear wall D C 34 1 2 MIN FLOOR FLOOR A B G F E FIGURE 1 STANDARD INSTALLATION INSTRUCTIONS ...

Страница 3: ...GURE 5A STEP 3 SURFACE INSTALLATION A BOTTOM DUCT ASSEMBLY Place the Bottom duct in the center of the opening so that gap A is equal to gap B When the BOTTOM DUCT ASSEMBLY is positioned properly the front edge of the duct will be flush with the front of the cabinet Secure with 2 SCREWS H See Figure 6 GAP A NOTE CENTER BOTTOM DUCT ASSEMBLY IN THE OPENING DETAIL A GAP B BOTTOM DUCT ASSEMBLY SCREW H ...

Страница 4: ...wdriver between the FRONT FRAME and the BACK FRAME and gently pry up to disengage the ball stud from the receiver Repeat for each corner See Figure 9 FIGURE 9 E BACK FRAME INSTALLATION Position BACK FRAME equal space top to bottom side to side Mark for 4 holes center punch and pre drill with 1 16 drill bit Secure frame with 4 SCREWS G See Figure 10 EQUAL GAP TOP BOTTOM EQUAL GAP SIDE TO SIDE MOUNT...

Страница 5: ...heat Do not reduce this spacing as doing so will void the warranty for any issues resulting from a lack of airflow NOTE Please allow minimum 3 76 mm wood gap between the microwave oven cutout and the appliance cutout below the microwave oven See Figure 2 3 76 MM Min Microwave cutout Wall oven cutout FIGURE 2 The floor of the opening should be constructed of plywood strong enough to support the wei...

Страница 6: ...REWS I provided See Figure 6 SCREW I SCREW I SCREW I DUCT A 3 DUCT A 2 FIGURE 6 E Remove SCREWS from the upper right and left corners at the rear of the oven Place duct assembly on the top of the unit as shown and secure the duct assembly to the oven using the 2 SCREWS just removed from the oven See Figure 6B SCREW SCREW FIGURE 6B STEP 3 EXHAUST DUCT ASSEMBLY INSTALLATION A Place the Exhaust Duct ...

Страница 7: ...SASSEMBLY The FRONT FRAME and BACK FRAME come pre assembled with ball studs engaged in the receivers Separate the FRONT FRAME from the BACK FRAME Place the assembly facedown onto a protected surface At the location of the ball stud insert a flathead screwdriver between the FRONT FRAME and the BACK FRAME and gently pry up to disengage the ball stud from the receiver Repeat for each corner See Figur...

Страница 8: ...ds and receivers Secure the FRONT FRAME to the BACK FRAME by firmly pushing the FRONT FRAME onto the BACK FRAME engaging the 4 snap attachments See Figures 13 14 Snap Attachment FIGURE 13 FIGURE 14 SHARP ELECTRONICS CORPORATION 100 Paragon Drive Montvale New Jersey 07645 U S A SHARP ELECTRONICS OF CANADA LTD 335 Britannia Road East Mississauga Ontario L4Z 1W9 Canada For any other assistance or inf...

Страница 9: ...e d encastrement Retirez le plateau rotatif de la cavité du four Une précaution particulière devrait être prise lors de la manipulation et de l installation de cet ensemble afin d éviter toute blessure puisque celui ci contient des pièces de métal ARTICLE NOMS DES PIÈCES QTÉ A CONDUIT A 1 PDUC 0259WRW0 1 B CONDUIT A 2 PDUC B127MRP0 1 C CONDUIT A 3 PDUC A734WRW0 1 D CONDUIT B PDUC 0260WRW0 1 E COND...

Страница 10: ...E Min 511 2 mm 201 8 po Min 511 2 mm 201 8 po F 127 mm 5 po 127 mm 5 po G 254 mm 10 po 254 mm 10 po La prise NE doit PAS se trouver dans l aire ombrée comme illustré à la schéma 1 REMARQUE Si la profondeur E dépasse 533 4 mm 21 po l emplacement de la prise peut être situé n importe où sur le mur arrière D C 34 1 2 MIN FLOOR FLOOR A B G F E PLANCHER PLANCHER MIN 87 6 CM 34 1 2 PO SCHÉMA 1 INSTRUCTI...

Страница 11: ...ASSEMBLAGE DU CONDUIT INFÉRIEUR Placer le conduit inférieur au centre de l ouverture de sorte que l écart A soit égal à l écart B Lorsque l assemblage du conduit inférieur est placé correctement le rebord avant du conduit sera aligné avec le devant de l armoire Fixer à l aide des 2 VIS H Voir schéma 6 ÉCART A DÉTAIL A ÉCART B ASSEMBLAGE DU CONDUIT INFÉRIEUR VIS H REMARQUE CENTRER L ASSEMBLAGE DU C...

Страница 12: ...cepteur Répétez pour chaque coin Voir Sketch 9 SCHÉMA 9 E INSTALLATION DU CADRE ARRIÈRE Placer le cadre arrière à distances égales de haut en bas et de chaque côté Tracer l emplacement de quatre 4 trous au centre à l aide d un poinçon et prépercer à l aide d une mèche de 1 45 mm 1 16 po Fixer le cadre à l aide de quatre 4 VIS G Voir schéma 10 EQUAL GAP TOP BOTTOM EQUAL GAP SIDE TO SIDE MOUNTING HO...

Страница 13: ... de l appareil Ne réduisez pas cet espace car ceci annulerait la garantie pour tout problème associé à un manque de circulation d air REMARQUE Laissez un dégagement minimum de 76 mm 3 po entre le gabarit du four à micro ondes et le gabarit de l appareil sous le four micro ondes Consultez la schéma 2 3 76 MM Min Microwave cutout Wall oven cutout Minimum de 76 mm 3 po Gabarit du micro ondes Gabarit ...

Страница 14: ...NDUIT A 3 CONDUIT A 2 SCHÉMA 6 E Retirer la VIS des coins supérieurs droit et gauche à l arrière du four Placer l ensemble conduit au dessus de l appareil comme illustré et fixer l ensemble conduit sur le four à l aide des deux vis qui viennent d être retirées Voir schéma 6A VIS VIS SCHÉMA 6A ÉTAPE 3 INSTALLATION DE L ASSEMBLAGE DU CONDUIT D ÉCHAPPEMENT A Positionnez l assemblage du conduit d écha...

Страница 15: ...ec des pivots à rotule insérés dans les récepteurs Séparez le CADRE AVANT du CADRE ARRIÈRE Placez l assemblage vers le bas sur une surface protégée À l emplacement du pivot à rotule insérez le tournevis à tête plate entre le CADRE AVANT et le CADRE ARRIÈRE et effectuez un mouvement de levier pour désengager le pivot à rotule du récepteur Répétez à chaque coin Consultez la schéma 10 SCHÉMA 10 D INS...

Страница 16: ...RIÈRE et alignez les pivots à rotule et les récepteurs Fixez le CADRE AVANT au CADRE ARRIÈRE en appuyant fermement sur le CADRE AVANT sur le CADRE ARRIÈRE en enclenchant les 4 fixations à pression Consultez les schéma 13 14 Snap Attachment Fixation à pression SCHÉMA 13 SHARP ÉLECTRONIQUE DU CANADA LTÉE 335 rue Britannia Est Mississauga Ontario L4Z 1W9 Canada Pour tout autre type d aide ou de rense...

Отзывы: