R-350F
5
FUNCTION OF IMPORTANT COMPONENTS
closed. However, when abnormally high temperatures are
reached within the oven cavity, the oven thermal cut-out
will open at 125˚C, causing the oven to shut down. The
defective thermal cut-out must be replaced with new one.
MAGNETRON THERMAL CUT-OUT
The thermal cut-out located near the magnetron is de-
signed to prevent damage to the magnetron if an over
heated condition develops in the tube due to cooling fan
failure, obstructed air guide, dirty or blocked air intake, etc.
Under normal operation, the thermal cut-out remains
closed. However, when abnormally high temperatures are
reached within the magnetron, the thermal cut-out will
open at 95˚C causing the oven to shut down, when the
magnetron has cooled to 75˚C, the thermal cut-out closes
and cook cycle will resume.
TURNTABLE MOTOR
The turntable motor drives the turntable roller assembly to
rotate the turntable.
FAN MOTOR
The fan motor drives a blade which draws external cool air.
This cool air is directed through the air vents surrounding
the magnetron and cools the magnetron. This air is chan-
nelled through the oven cavity to remove steam and
vapours given off from the heating foods. It is then ex-
hausted through the exhausting air vents at the oven
cavity.
NOISE FILTER
The noise filter prevents the radio frequency interference
that might flow back in the power circuit.
DOOR OPEN MECHANISM
The door is opened by pulling the door, refer to the Figure
D-1.
Figure D-1. Door Open Mechanism
1ST. LATCH SWITCH AND 2ND. INTERLOCK
RELAY CONTROL SWITCH
1. When the oven door is closed, the contacts (COM-NO)
must be closed.
2. When the oven door is opened, the contacts (COM-
NO) must be opened.
MONITOR SWITCH
1. When the oven door is closed, the contacts (COM-NC)
must be opened.
2. When the oven door is opened, the contacts (COM-
NC) must be closed.
3. If the oven door is opened and the contacts (COM-NO)
of the 1st. latch switch and 2nd. interlock relay fail to
open, the fuse F10A blows simultaneously with closing
the contacts (COM-NC) of the monitor switch.
CAUTION: BEFORE REPLACING A BLOWN FUSE F10A
TEST THE 1ST. LATCH SWITCH, 2ND.
INTERLOCK RELAY AND MONITOR
SWITCH FOR PROPER OPERATION.
HIGH VOLTAGE FUSE
The high voltage fuse blows when the high voltage rectifier
or magnetron is shorted.
FUSE F10A
1. The fuse F10A blows when the contacts (COM-NO) of
the 1st. latch switch and 2nd. interlock relay remain
closed with the oven door open and when the monitor
switch closes.
2. If the wire harness or electrical components are short-
circuited, this fuse F10A blows to prevent an electric
shock or fire hazard.
OVEN THERMAL CUT-OUT
The thermal cut-out, located on the top of the oven cavity,
is designed to prevent damage to the oven by fire. If the
foods load is overcooked, by either error in cook time or
defect in the control unit, the thermal cut-out will open.
Under normal operation, the oven thermal cut-out remains
Latch Hook
2nd. Interlock
Reley Control
Switch
Latch
Heads
Door
Monitor Switch
1st. Latch
Switch
Содержание Carousel R-350F
Страница 2: ...R 350F 36 ...