20
R-312AW
R-312AK
HIGH VOLTAGE RECTIFIER AND HIGH VOLTAGE CAPACITOR REMOVAL
1. Disconnect oven from power supply and remove outer
case.
2. Discharge high voltage capacitor.
3. Remove the power supply cord, referring the "POWER
SUPPLY CORD REPLACEMENT".
4. Disconnect wire leads from the noise filter.
5. Remove one (1) screw holding the noise filter angle to
the oven cavity back plate.
6. Remove the noise filter angle with noise filter from the
oven cavity back plate.
7. Disconnect the high voltage wire B from the high voltage
capacitor.
8. Disconnec t he high voltage wire of high voltage rectifier
assembly from the magnetron.
9. Remove one (1) screw holding capacitor holder to oven
cavity rear plate.
10.Disconnect rectifier terminal from capacitor.
High voltage rectifier assembly is now free.
11.Remove one (1) screw holding high voltage rectifier
assembly to capacitor holder.
12.Remove capacitor holder. Capacitor is now free.
CAUTION: WHEN REPLACING HIGH VOLTAGE RECTI-
FIER AND HIGH VOLTAGE CAPACITOR,
GROUND SIDE TERMINAL OF THE HIGH
VOLTAGE RECTIFIER MUST BE SECURED
FIRMLY WITH A GROUNDING SCREW.
Removal
1. Disconnect oven from power supply and remove outer
case.
2. Discharge high voltage capacitor.
3. Disconnect wire leads from magnetron.
4. Remove the one (1) screw holding chassis support to
magnetron.
5. Remove the chassis support from oven.
6. Carefully remove the two (2) screws holding magnetron
to waveguide flange.
7. Lift up magnetron with care so that magnetron antenna
is not hit by any metal object around antenna.
8. Now, the magnetron is free.
Re-install
1. Re-install the magnetron to waveguide flange with the
two (2) screws diagonally as shown in Figure C-1.
2. Insert the two (2) tabs of the chassis support to the oven
cavity front plate and the back plate.
3. Re-install the chassis support to magnetron with the one
(1) screw.
MAGNETRON REMOVAL
4. Reconnect the wire leads to the magnetron. Refer to
"PICTORIAL DIAGRAM".
5. Re-install outer case and check that the oven is operating
properly.
CAUTION: WHEN REPLACING MAGNETRON, BE SURE
THE R.F. GASKET IS IN PLACE AND MOUNT-
ING SCREWS ARE TIGHTENED SECURELY
Figure C-1. Magnetron replacement
SCREWS
WAVEGUIDE
FLANGE
MAGNETRON
Removal
1. Disconnect oven from power supply and remove outer
case.
2. Discharge high voltage capacitor.
3. Disconnect the white and black wires of the power supply
cord from the noise filter.
4. Remove the one (1) screw holding the earth wire of the
power supply cord to the bottom plate right.
5. Remove the power supply cord from the oven cavity
back plate.
Re-install
1. Insert the power supply cord into the oven cavity back
plate.
2. Connect the white and black wires of the power supply
cord into the terminal of noise filter, referring to the
Pictorial Diagram.
3. Re-install the earth wire of the power supply cord to the
bottom plate right with the one (1) screw.
POWER SUPPLY CORD REPLACEMENT
Figure C-2. Power supply cord replacement
Noise
filter
Power supply cord
Oven cavity
back plate
Black wire
White wire
Green wire
Bottom plate right
N
RED
GRY
H