AR-M236/M276/M237/M277 SIMULATION 8 - 15
Operation/procedure
Enter the set value with the 10-key.
When the duplex motor setting is made, the duplex 2motor is also set
accordingly.
Operation/procedure
1.
Touch the item to set.
2.
Enter the set value with the 10-key, and press the [START] key.
Operation/procedure
Press the [START] key and operate the toner motor for 30 sec.
Operation/procedure
1.
Press the [START] key.
2.
When "1: YES" is selected, troubles other than U2 and PF are can-
celed. (When "2: NO" is selected, the simulation is canceled.)
Operation/procedure
1.
Press the [START] key.
2.
When "1: YES" is selected, U2 trouble is canceled. (When "2: NO"
is selected, the simulation is canceled.)
Operation/Procedure
1.
Press the [START] key.
2.
When "1: YES" is selected, PF trouble is canceled. (When "2: NO"
is selected, the simulation is canceled.)
Setting range
1-13
Default
3
9-5
Purpose
Adjustment
Function
(Purpose)
Used to adjust the timing of switching from normal
rotation to reverse rotation or from reverse rotation to
normal rotation of the duplex motor.
Item
Installation range
Default
1
600dpi
18-76
18
2
1200dpi
50
10
10-0
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of the toner motor and its
control circuit.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Developer/Toner hopper
Item
Operation
14
14-0
Purpose
Clear/Cancel (Trouble etc.)
Function
(Purpose)
Used to cancel excluding the self-diag U2/PF troubles.
Item
Trouble
Error
16
16-0
Purpose
Clear/Cancel (Trouble etc.)
Function (Purpose)
Used to cancel the self-diag U2 trouble.
Item
Trouble
Error
17
17-0
Purpose
Cancel (Trouble, etc)
Function (Purpose)
Used to cancel the self diag "PF" trouble.
Item
Trouble
Error
21
21-1
Purpose
Setting
Function (Purpose)
Used to set the maintenance cycle.
Item
Specifications
Counter