![Sharp AR-C150 Скачать руководство пользователя страница 205](http://html.mh-extra.com/html/sharp/ar-c150/ar-c150_service-manual_367444205.webp)
Simulation
Code
Content/Item
Set range
Default
Model
NOTE
Data store
location
Main Sub.
AR-
C100
AR-
C150
AR-
C250
AR-
C160/
C270
26
55
Fusing capability (Image
process) setup in the
heavy paper mode
(AR-C150)
ENABLE/DISABLE
ON/OFF
∗
❍
The default value
differs depending on
the destination.
EEPROM
(ICU PWB)
Select the gamma
characteristics in the color
copy mode (AR-C250)
ENABLE/DISABLE
ON/OFF
∗
❍
❍
The default value
differs depending on
the destination.
27
01
PC/MODEM
communication trouble
(U7-00) detection
YES/NO setup
A: PC/MODEM communication
trouble (U7-00) detection
YES/NO
0 – 1
0
❍
❍
❍
❍
EEPROM
(PCU PWB)
02
Host computer/Modem
number setup
Host computer/MODEM number
❍
❍
❍
❍
EEPROM
(PCU PWB)
03
Machine/Host computer
MODEM ID number setup
Machine/Host computer modem
ID number
❍
❍
❍
❍
EEPROM
(PCU PWB)
05
Tag number setup
Tag number
❍
❍
❍
❍
EEPROM
(PCU PWB)
06
Manual service call
Enable/Disable setup
A: Manual service call YES/NO
0 – 1
0
❍
❍
❍
❍
EEPROM
(PCU PWB)
29
04
Printer mode fee-charging
setup
0 – 2
(0 – 4)
∗
2
0
❍
❍
❍
EEPROM
(PCU PWB)
40
02
Manual feed tray paper
width detection level
adjustment
A: Paper guide max. position level
❍
❍
❍
The adjustment value
cannot be entered
directly.
EEPROM
(PCU PWB)
B: Paper guide min. position level
❍
❍
❍
05
OHP sensor detection
level adjustment
❍
❍
❍
The adjustment value
cannot be entered
directly.
EEPROM
(PCU PWB)
06
OHP sensor adjustment
parameter set up
A: OHP sheet use Enable/Disable
setup
0 – 1
1
❍
❍
❍
EEPROM
(PCU PWB)
B: OHP sensor adjustment target
level
0 – 255
200
❍
❍
❍
C: OHP paper judgement
reference level
0 – 255
120
❍
❍
❍
41
02
Original size sensor
adjustment
Adjustment value (PD1 – 7)
0 – 255
128
❍
❍
❍
❍
The adjustment value
cannot be entered
directly.
EEPROM
(PCU PWB)
43
01
Fusing temperature setup
(AR-C100/C150)
A: Temperature set value (upper)
70 – 200
❍
❍
The set value
(default) differs
depending on the
destination. Refer to
the details of SIM
43-01.
EEPROM
(PCU PWB)
B: Temperature set value (lower)
70 – 200
❍
❍
C: Temperature set value (Ready
upper)
70 – 200
❍
❍
D: Temperature set value (Ready
lower)
70 – 200
❍
❍
E: Temperature set value (Energy
saving upper)
70 – 200
❍
❍
F: Temperature set value (Energy
saving reset)
70 – 200
❍
❍
G: Temperature set value (Thick
paper upper)
70 – 200
❍
H: Temperature set value (Thick
paper lower)
70 – 200
❍
I: Temperature set value (OHP
upper)
70 – 200
❍
J: Temperature set value (OHP
lower)
70 – 200
❍
∗
2: AR-C250/C270
14 – 10A
Содержание AR-C150
Страница 35: ... 5 EXTERNAL VIEW AND INTERNAL STRUCTURE ...
Страница 63: ...125mm 125mm 125mm Check the deflection of 125mm pitch Deflection pattern of Magenta A3 or 11 x 17 7 9 ...
Страница 135: ... 10 SELF DIAG MESSAGE AND TROUBLESHOOTING ...
Страница 202: ... 14 OTHERS ...