AR-5127 SIMULATION 8 - 33
Operation/procedure
Enter the adjustment value with the 10-key and press the [OK] key, and
the entered value is registered.
Operation/procedure
Select the mode with the arrow keys, enter the adjustment value with
the 10-key, and press the [OK] key.
When the [START] key is pressed, a print is made and the display
returns to the mode selection menu.
Setup of various copy conditions: Similar to the normal copy mode.
Use of [SPECIAL FUNCTION] key, [JOB STATUS] key, and [INTER-
RUPT] key is inhibited.
Operation/procedure
Enter the adjustment value with the 10-key and press the [OK] key, and
the entered value is registered.
Operation/procedure
Used to adjust ON/OFF timing of the separation voltage.
51
51-1
Purpose
Adjustment
Function
(Purpose)
Used to adjust the OPC drum separation pawl ON
time.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Item
Operation
(Initial screen)
(Input screen)
Display items
Setting range
Default
1:600dpi
1-99
50
2:1200dpi
Disabled
51-2
Purpose
Adjustment
Function
(Purpose)
Used to adjust the contact pressure of paper onto the
resist roller in each section (copier paper feed section,
duplex paper feed section, SPF paper feed section).
(When the print image position varies greatly for the
paper or when a lot of paper jam troubles occur, the
adjustment is required.)
Section
Paper transport (Discharge/Switchback/Transport)
Item
Operation
(Initial screen)
(Input screen)
(Executing screen)
Display items
Content
Setting
range
Default
Remark
1:BYPASS
Manual feed
1-99
50
Tray selection:
Manual feed
cassette is
specified.
2:TRAY1
1st cassette
1-99
50
Tray selection:
1st cassette is
specified.
3:TRAY2
2nd cassette
1-99
50
Tray selection:
2nd cassette is
specified.
4:TRAY3
3rd cassette
1-99
50
Tray selection:
3rd cassette is
specified.
5:TRAY4
4th cassette
1-99
50
Tray selection:
4th cassette is
specified.
6:DUPLEX
Back print
1-99
50
Tray selection:
Made by user.
7:SPF(SIDE1)
SPF front
surface
1-99
50
Tray selection:
Made by user.
Sim51-1 D/F TIMING
1:600dpi 50
2:1200dpi 50
2
Sim51-1 D/F TIMING
2:1200dpi 50
[ 1- 99]
50
Sim51-2 RESIST ADJ.
1:BYPASS
50
2:TRAY1 50
3:TRAY2 50
1/3
50
8:SPF(SIDE2)
SPF back
surface
Tray selection:
Made by user.
51-8
Purpose
Setting
Function
(Purpose)
Used to set to disable the operation of the separation
pawl of the photoconductor drum.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Item
Operation
Display items
Content
Setting range
Default
0:ON
Enable
0-1
0
1:OFF
Disable
51-9
Purpose
Adjustment
Function
(Purpose)
Used to adjust ON/OFF timing of the separation
voltage.
Item
Adjustment
(Initial screen)
(Input screen)
Display
items
Content
Setting
range
Default
1:SHV ON
Separation voltage ON timing
* Transfer V2ON reference
(synchronized with the
adjustment value of 50)
25-90
50
2:SHV OFF
Separation voltage OFF timing
* Transfer V2OFF reference
(synchronized with the
adjustment value of 50)
50-90
75
Display items
Content
Setting
range
Default
Remark
Sim51-8 D/F SETTING
DETACH FINGER
0
(0:ON
1:OFF)
[ 0- 1]
1
Sim51-9 SHV SETTING
1:SHV ON 50
2:SHV OFF 50
1
Sim51-9 SHV SETTING
1:SHV ON 50
[ 1- 99]
50
Содержание AR-5127
Страница 93: ......