LC-60/70LE600U
5 – 2
3. Entering and exiting the adjustment process mode
1) Before entering the adjustment process mode, the AV position RESET in the video adjustment menu.
2) While holding down the “VOL (–)” and “INPUT” keys at a time, plug in the AC cord of the main unit to turn on the power.
The letter “<K>” appears on the screen.
3) Next, hold down the “VOL (–)” and “CH (
)” keys at a time.
(The “VOL (–)” and “CH (
)” keys should be pressed and held until the display appears.)
Multiple lines of white characters appearing on the display indicate that the unit is now in the adjustment process mode.
When you fail to enter the adjustment process mode (the display is the same as normal startup), retry the procedure.
4) To exit the adjustment process mode after the adjustment is done, unplug the AC cord from the outlet to make a forced shutdown. (When the
power was turned off with the remote controller, once unplug the AC cord and plug it again. In this case, wait 10 seconds or so before plugging.)
CAUTION: Use due care in handling the information described here lest your users should know how to enter the adjustment process mode. If the
settings are tampered in this mode, unrecoverable system damage may result.
4. Remote controller key operation in adjustment process mode
*Input mode is switched automatically when relevant adjustment is started so far as the necessary input signal is available.
5. List of adjustment process mode menu
Remote controller key
Main unit key
Function
CH (
/
)
CH (
/
)
Moving an item (line) by one (UP/DOWN)
VOL (+/–)
VOL (+/–)
Changing a selected item setting (+1/ –1)
Cursor (UP/DOWN)
—————
Turing a page (PREVIOUS/NEXT)
Cursor (LEFT/RIGHT)
—————
Changing a selected line setting (+10/ –10)
INPUT
—————
Input switching (toggle switching)
ENTER
—————
Executing a function
Page
Line
Item
Description
Remarks
1
1
Main Version
Main software version
BL: boot loader version
2
Check Sum
Flash check sum
3
PANEL Version
4
TEMP SENSOR
5
NORMAL STANDBY CAUSE
Normal standby cause
6
ERROR STANDBY CAUSE
Error standby cause
2
1
Factory Init
Initialization to factory settings
2
Inch Setting
Inch size
3
Public Mode
Public mode
Not available
4
Operation Acutime
Accumulated operation time
5
RESET
Reset
3
1
RF-AGC ADJ
Not available
2
TUNER ADJ
Not available
3
PAL ADJ
Not available
4
RF AGC
Not available
5
TUNER Level
Not available
6
CVBS Level
Not available
7
VIF
Not available
8
VIDEO AGC
Not available
4
1
COMP SD ADJ
Component 15K picture level adjustment
2
Y OFFSET
3
Cb OFFSET
4
Cr OFFSET
5
Y GAIN
6
Cb GAIN
7
Cr GAIN
8
RESET ADJUSTMENT
Reset
5
1
COMP HD ADJ
Component 33K picture level adjustment
2
Y OFFSET
3
Pb OFFSET
4
Pr OFFSET
5
Y GAIN
6
Pb GAIN
7
Pr GAIN
8
RESET ADJUSTMENT
Reset
Содержание Aquos LC-60LE600U
Страница 6: ...LC 60 70LE600U 1 1 LC 60LE600U Service Manual CHAPTER 1 SPECIFICATIONS 1 SPECIFICATIONS ...
Страница 7: ...LC 60 70LE600U 2 1 LC 60LE600U Service Manual CHAPTER 2 OPERATION MANUAL 1 PARTS NAMES ...
Страница 8: ...LC 60 70LE600U 2 2 2 OPERATION MANUAL ...
Страница 9: ...LC 60 70LE600U 2 3 ...
Страница 10: ...LC 60 70LE600U 2 4 ...
Страница 11: ...LC 60 70LE600U 2 5 ...
Страница 12: ...LC 60 70LE600U 3 1 LC 60LE600U Service Manual CHAPTER 3 DIMENSIONS 1 DIMENSIONS ...
Страница 46: ...LC 60 70LE600U 8 2 2 SYSTEM BLOCK DIAGRAM 1 2 3 10 9 7 6 5 4 8 J A B C D E F G H I 13 11 19 18 16 15 14 12 17 ...
Страница 57: ...LC 60 70LE600U ...
Страница 67: ...LC 60 70LE600U ...