background image

3

LC-26GD6U

12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212

12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212

12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212

12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212

12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212

12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212

SAFETY NOTICE

Many electrical and mechanical parts in Liquid Crystal
c o l o r   t e l ev i s i o n   h a ve   s p e c i a l   s a fe t y - r e l a t e d
characteristics.
These characteristics are often not evident from visual
inspection, nor can protection afforded by them be
necessarily increased by using replacement components
rated for higher voltage, wattage, etc.
Replacement parts which have these special safety
characteristics are identified in this manual; electrical

components having such features are identified by “ 

å

and shaded areas in the

 Replacement Parts List and

Schematic Diagrams.
For continued protection, replacement parts must be
identical to those used in the original circuit.
The use of a substitute replacement parts which do not
have the same safety characteristics as the factory
recommended replacement parts shown in this service
manual, may create shock, fire or other hazards.

WARNING

1. For continued safety, no modification of any circuit

should be attempted.

2. Disconnect AC power before servicing.

BEFORE RETURNING THE RECEIVER
(Fire & Shock Hazard)

Before returning the receiver to the user, perform
the following safety checks:

1. Inspect all lead dress to make certain that leads are

not pinched, and check that hardware is not lodged
between the chassis and other metal parts in the
receiver.

2. Inspect all protective devices such as non-metallic

control knobs, insulation materials, cabinet backs,
adjustment and compartment covers or shields,
isolation resistor-capacitor networks, mechanical
insulators, etc.

3. To be sure that no shock hazard exists, check for

leakage current in the following manner.

»

Plug the AC cord directly into a 120 volt AC outlet.

»

Using two clip leads, connect a 1.5k ohm, 10 watt
resistor paralleled by a 0.15µF capacitor in series
with all exposed metal cabinet parts and a known
earth ground, such as electrical conduit or electrical
ground connected to an earth ground.

»

Use an AC voltmeter having with 5000 ohm per volt,
or higher, sensitivity or measure the AC voltage drop
across the resistor.

»

Connect the resistor connection to all exposed metal
parts having a return to the chassis (antenna, metal
cabinet, screw heads, knobs and control shafts,
escutcheon, etc.) and measure the AC voltage drop
across the resistor.
All checks must be repeated with the AC cord plug
connection reversed. (If necessary, a nonpolarized
adaptor plug must be used only for the purpose of
completing these checks.)
Any reading of 0.75V rms (this corresponds to 0.5
mA rms AC.) or more is excessive and indicates a
potential shock hazard which must be corrected
before returning the monitor to the owner.

IMPORTANT SERVICE SAFETY PRECAUTION

Ë

Service work should be performed only by qualified service technicians who are thor-
oughly familiar with all safety checks and the servicing guidelines which follow:

C AU T I O N :  F O R   C O N T I N U E D
PROTECTION AGAINST A RISK OF
FIRE REPLACE ONLY WITH SAME
TYPE FUSE.
F701 (3.15A, 250V),  F702 (3.15A,
250V), F703 (2A, 250V), F705 (1A,
DC450V), F706 (5A, 250V), F707 (5A,
250V)

A     V

DVM

AC SCALE

1.5k ohm

10W

TO EXPOSED
METAL PARTS

CONNECT TO
KNOWN EARTH
GROUND

0.15 F

TEST PROBE

Содержание Aquos LC-26GD6U

Страница 1: ...r sales service only The contents are subject to change without notice CONTENTS Page LIST OF CHANGED PARTS 2 IMPORTANT SERVICE SAFETY PRECAUTION 3 SPECIFICATIONS 6 OPERATION MANUAL 7 DIMENSIONS 13 REMOVING OF MAJOR PARTS 14 DESCRIPTION OF SCHEMATIC DIAGRAM 18 SCHEMATIC DIAGRAM 19 PARTS LIST 21 PACKING OF THE SET 25 OUTLINE This model is based on the LC 26GD4U and is equipped with a redesigned spea...

Страница 2: ... parts changed R C LED Unit DUNTKC672UJ03 DUNTKC672UJ01 No parts changed EXT SP TERMINAL Unit DUNTKC673UJ03 DUNTKC673UJ01 One Parts changed INVERTER Unit RUNTKA075WJZZ No parts changed INVERTER GND Unit RUNTKA076WJZZ No parts changed POWER Unit RDENCA071WJZZ No parts changed 1 Bit Amplifier Unit B2SX4102BT No parts changed LCD PANEL 26 Wide LCD Panel Unit RLCDTA029WJZZ LCD CONTROL Unit R2026 Metal...

Страница 3: ... all lead dress to make certain that leads are not pinched and check that hardware is not lodged between the chassis and other metal parts in the receiver 2 Inspect all protective devices such as non metallic control knobs insulation materials cabinet backs adjustment and compartment covers or shields isolation resistor capacitor networks mechanical insulators etc 3 To be sure that no shock hazard...

Страница 4: ...trocutions incendies radiations X ou autres accidents AVERTISSEMENT 1 N entreprendre aucune modification de tout circuit C est dangereux 2 Débrancher le récepteur avant toute réparation VERIFICATIONS CONTRE L INCEN DIE ET LE CHOC ELECTRIQUE Avant de rendre le récepteur à l utilisateur effectuer les vérifications suivantes 1 Inspecter tous les faisceaux de câbles pour s assurer que les fils ne soie...

Страница 5: ...s higher than the conventional lead solder by 40 C and as it has poor solder wettability you may be apt to keep the soldering bit in contact with the PWB for extended period of time However since the land may be peeled off or the maximum heat resistance temperature of parts may be exceeded remove the bit from the PWB as soon as you confirm the steady soldering condition Lead free solder contains m...

Страница 6: ...ack CENTER CHANNEL INPUT RCA pin 4 Ω 10W L R EXTERNAL SPEAKER INPUT 5 Audio in DVI I in with HDCP Digital Terrestrial Broadcast 8VSB 2 69ch Digital cable 64 256 QAM 1 135ch 150 W 7 6 W Standby with AC 120 V 26 Advanced Super View BLACK TFT LCD DIGITAL ANTENNA 75 Ω Unbalance F Type for Digital Air Cable in 1 DIGITAL AUDIO OUTPUT Optical Digital audio output 1 PCM Dolby Digital i LINK IEEE1394 2 wit...

Страница 7: ...up NOTE Pressing RESET will not work if the System is in standby mode Pressing RESET will not delete channel preset or secret number See page 66 for clearing the secret number when you know it See page 100 for initializing to the factory preset values when you forget your secret number RESET INPUT 3 terminals SYSTEM RESET ANALOG A IN terminal ANALOG B IN terminal ANALOG A OUT terminal DC OUTPUT te...

Страница 8: ...xternal mode See page 22 21 INPUT Selects a Liquid Crystal Television input source TV INPUT 1 INPUT 2 INPUT 3 INPUT 4 INPUT 5 i LINK Card See pages 50 and 66 22 DIGITAL Receives digital broadcasts 23 CH Selects the channel 24 MUTE Mutes the sound See page 23 25 CH LIST Displays the channel list screen 26 MENU Displays the menu screen 27 Selects a desired item on the screen 28 RETURN Returns to the...

Страница 9: ...26GD6U Put the Ferrite core in the space as shown in the figure If the AC cord is not put in properly the terminal cover may not close for LC 26GD6U for LC 32GD6U Ferrite core Ferrite core Removing speakers NOTE To attach the speakers perform the steps in reverse order CAUTION Do not remove the stand and speaker from the Display unless using an optional bracket to mount it Before performing work s...

Страница 10: ...two AAA size batteries supplied with the pr oduct Place the batteries with their ter minals corr esponding to the and indications in the battery compartment 3 Close the battery cover CAUTION Improper use of batteries can result in chemical leakage or explosion Be sure to follow the instructions below Place the batteries with their terminals corresponding to the and indications Do not mix batteries...

Страница 11: ...DEO COMPONENT DIGITAL PC ANALOG PC DIGITAL AV ANALOG AV Toggle STANDARD MOVIE USER GAME DYNAMIC Fixed DYNAMIC Volume 0 60 AV mode 10 PC mode 0 180 AV mode 20 PC mode 0 100 Only PC mode 0 180 Only PC mode 0 40 Toggle AV An input change is included if it is not TV display In Air 2 69ch is effective In Cable 1 125ch is effective If it is not TV display it will input switch to TV same function as CH I...

Страница 12: ...e Reduction HDMI Setup Input Select Output Select Quick Shoot Center Channel Input Caption Setup Title Display Type Audio Power Control Setup Option CableCARD Menu Video Setup Audio Setup i LINK Setup Digital Setup Power Management Speaker Setup Input Signal Auto Sync Input Label Fine Sync Picture Flip Language Power Control Setup Option Audio Only Input Select Output Select Quick Shoot Center Cha...

Страница 13: ...LC 26GD6U DIMENSIONS Unit inch mm 1031 32 279 3 47 64 95 2027 64 519 2223 64 568 12 5 8 321 263 32 663 8 7 64 206 21 7 8 556 7 29 32 201 19 53 64 504 2 1 32 52 245 64 69 359 64 100 3 59 64 100 5 15 16 151 ...

Страница 14: ...rom the top cover 7 2 Remove the 2 lock screws from the operation PWB 8 Remove the lock screw and detach the frame cover 9 Remove the 5 lock screws from the frame 10 Disconnect all the connectors from the PWBs 3 3 5 5 2 2 4 2 Terminal Cover left Terminal Cover right Cabinet A 1 Stand Bracket Cover Bracket Cover P2002 P7706 P5706 P1902 P5251 P3802 P1901 P1900 P151 6 8 9 9 7 1 7 2 Center Angle Frame...

Страница 15: ...lock screws from the AV sub PWB 12 3 Remove the 4 lock screws from the AV sub PWB 13 Remove the 3 lock screws from the cooling fan 14 Disconnect all the connectors from the PWBs Main PWB Shield P7708 PA120WJ 13 Cooling Fan AV Sub PWB Shield AV Sub PWB Flap Door PC Card PWB PWB Shield Earth Plate Main PWB Digital PWB Frame Frame Cover 12 1 12 3 12 3 11 1 11 1 11 2 11 2 11 2 11 2 11 4 11 3 CN7602 CN...

Страница 16: ...e the 4 lock screws from the speaker angle right 23 Remove the 4 lock screws from the center angle 24 Remove the 4 lock screws from the speaker angle left 25 Remove the 2 lock screws from the R C LED PWB 26 Remove the 4 lock screws from the reinforcement angle 27 Remove the 2 lock screws from the LCD panel LCD Control PWB Inverter PWB Power PWB AV PWB Frame AV PWB Speaker Connection PWB Inverter G...

Страница 17: ...p holder top 31 Take the lamp unit out of the lamp clip Lamp Holder Top CHLDZA328WJ01 Lamp Holder Top CHLDZA328WJ01 Diffusion Plate PCOVUA026WJZZ Diffusion Sheet PSHEPA166WJZZ Prism Sheet PSHEPA165WJZZ Reflection Deflection Sheet PSHEPA164WJZZ Sheet Spacer S Sheet Spacer A PSPAZA484WJZZ Sheet Spacer S PSPAZA536WJZZ Sheet Spacer PSPAZA535WJZZ Lamp Unit KLMP A026WJZZ Back Shield 26 LCD Panel Unit 28...

Страница 18: ...TION OF RESISTOR CAPACITOR RESISTOR 1 The unit of resistance Ω is omitted K kΩ 1000 Ω M MΩ 2 All resistors are 5 unless otherwise noted J 5 F 1 D 0 5 3 All resistors are Carbon type unless otherwise noted C Solid W Cement S Oxide Film T Special N Metal Coating CAPACITOR 1 All capacitors are mF unless otherwise noted P pF mmF 2 All capacitors are Ceramic type unless otherwise noted ML Mylar TA Tant...

Страница 19: ...19 LC 26GD6U 6 5 4 3 2 1 A B C D E F G H Ë EXT SP TERMINAL Unit SCHEMATIC DIAGRAM ...

Страница 20: ...20 LC 26GD6U M E M O ...

Страница 21: ...t sont hachur élees dans les listes de pi eces et dans les diagrammes sch élematiques La substitution d une pi ece de rechange par une autre qui ne pr éLesente pas les m éoemes caract éLeristiques de s élecurit éle que la pi ece recommand élee parl usine et dans ce manuel de service peut provoquer une éLelectrocution un incendie ou toutautre sinistre COMMENT COMMANDER LES PIECES DE RECHANGE Pour q...

Страница 22: ...92 32 32 19 19 90 90 91 50 66 1 73 10 11 91 91 49 3 3 3 2 3 4 3 4 1 4 3 4 2 6 1 7 2 86 27 42 86 99 37 84 84 54 81 18 120 82 47 53 86 59 69 70 65 88 33 78 45 9 1 9 2 59 35 61 82 46 88 33 38 86 56 43 55 86 77 16 51 86 17 28 72 26 89 66 85 34 48 87 36 41 86 98 86 87 86 86 86 86 86 84 39 74 44 7 1 7 3 7 97 34 40 86 2 32 5 14 13 83 96 89 90 15 57 63 64 8 1 8 2 8 3 U 62 60 71 80 86 6 4 2 3 2 8 2 8 2 1 2...

Страница 23: ...287WJFW J Fixing Metal AM 42 PSLDMA368WJFW J Shield AK 43 PSPAGA203WJZZ J Spacer x2 AC 44 PSPAZA398WJKA J Spacer x2 AK 45 PSPAZA463WJKZ J Spacer x2 AQ 46 DUNTKC268VJ27 J LCD CONTROL Unit CH 1 CCABAA671WJ02 J Cabinet A Ass y BG 1 1 Not Available Cabinet A 1 2 GCOVAA709WJSA J R C LED Cover AF 1 3 HBDGBA037WJSA J Badge SHARP AM 1 4 PCOVUA043WJZZ J Light Shielding Cover AF 1 5 PSPAHA323WJZZ J Mask Spa...

Страница 24: ... Remote Control Unit BC TCADEA028WJN1 J Questionnaire Card AD TiNS B240WJZZ J Operation Manual AW 47 DKEYDC307VJ17 J DIGITAL Unit CV 48 DUNTKC670UJ01 AV Unit 49 DUNTKC671UJ01 KEY Unit 50 DUNTKC672UJ01 R C LED Unit 51 DUNTKC673UJ01 EXT SP TERMINAL Unit 53 DUNTKC641VJ07 J MAIN Unit CQ 54 DUNTKC544VJ03 J PC CARD Unit BY 55 RDENCA071WJZZ POWER Unit 56 RUNTKA075WJZZ J INVERTER Unit BN 57 RUNTKA076WJZZ ...

Страница 25: ...Case SPAKCB611WJZZ Packing Case for Accessory SPAKFA626WJZZ Wrapping Paper SPAKPA396WJZZ AC Cord QACCDA019WJPZ RF Cable QCNW A342WJZZ Remote Control Unit RRMCGA242WJSA Questionnaire Card TCADEA028WJN1 Operation Manual TiNS B240WJZZ Buffer Material Top SPAKXA549WJZZ Wrapping Paper Stand Side SPAKPA391WJZZ No Label TLABK0001TAZZ Joint SPAKL0023CEZZ Joint ...

Страница 26: ...nsmitted in any form or by any means electronic mechanical photocopying recording or otherwise without prior written permission of the publisher SHARP CORPORATION AV Systems Group Quality Reliability Control Center Yaita Tochigi 329 2193 Japan TQ1789 S Aug 2004 Printed in Japan SY KD Design and Production Information Design Japan Production Japan ...

Отзывы: