background image

2

 1

  Inlet (Air)

 2

  Open Panel

 3

  Air Filter

 4

  AUX Button

 5

  Receiver Window

 6

  Vertical 

Airflow Louv

re

 7

  Horizontal A

irflow Louvr

e

 8 

  Outlet (Air)

9

 

PLASM

A

CLUSTER Lamp

 

(blue) 

10

  OPERA

TION Lamp (

red   )

11

 

TIMER Lamp (o

range   )

12 

POWERFU

L

 JET

 Lamp

 

(green 

 )

NOTE:

Actual  units 

might

  vary  s

lightly

 

fro

m those 

s

hown abo

ve.

1
2
3

4

5

6
7
8

9
10
11
12

PART NAMES

INDOOR UNIT

AH-XPC9RV.indd   2

11.8.8   1:33:33 PM

Содержание AH-XPC12RV

Страница 1: ...DITIONER OPERATION MANUAL INDOOR UNIT AH XPC9RV AH XPC12RV Device of this mark is a trademark of Sharp Corporation Plasmacluster is a registered trademark or a trademark of Sharp Corporation AH XPC9RV indd 1 11 8 8 1 33 32 PM ...

Страница 2: ...AH XPC9RV indd 2 11 8 8 1 33 32 PM ...

Страница 3: ...o not attempt to install remove repair the unit by yourself Incorrect work will cause electric shock water leak fire etc Consult your dealer or other qualified service personnel for the installation removal repair of the unit CAUTION Open a window or door periodically to ventilate the room especially when using gas appliances Insufficient ventilation may cause oxygen shortage Do not operate the butto...

Страница 4: ... Louvre 7 Horizontal Airflow Louvre 8 Outlet Air 9 PLASMACLUSTER Lamp blue 10 OPERATION Lamp red 11 TIMER Lamp orange 12 POWERFUL JET Lamp green NOTE Actual units might vary slightly from those shown above 1 2 3 4 5 6 7 8 9 10 11 12 PART NAMES INDOOR UNIT AH XPC9RV indd 2 11 8 8 1 33 33 PM ...

Страница 5: ...ET Button 15 POWERFUL JET Button 16 SELF CLEAN Button 17 GENTLE COOL AIR Button DISPLAY 18 19 20 21 22 23 24 25 26 18 MODE Symbols AUTO COOL DRY 19 POWERFUL JET Symbol 20 SELF CLEAN Symbol 21 PLASMACLUSTER Symbol 22 FAN SPEED Symbols AUTO Manual setting 23 GENTLE COOL AIR Symbol 24 TEMPERATURE AND TIMER COUNT DOWN Indicator 25 TRANSMITTING Symbol 26 TIMER ON TIMER OFF Indicator 1 2 3 4 5 6 7 8 9 1...

Страница 6: ...ot leave the remote control in direct sunlight or near a heater Protect the remote control from moisture and shock Use this mode when the remote control is not available TO TURN ON Press the AUX button The red OPERATION lamp will light up and the unit will start operating in the AUTO mode The fan speed and temperature setting are set to AUTO TO TURN OFF Press the AUX button again The red OPERATION...

Страница 7: ... Press the FAN button to set the desired fan speed 2 3 1 4 BASIC OPERATION AUTO COOL DRY AUTO SOFT LOW HIGH NOTE AUTO MODE In the AUTO mode the temperature setting and mode are automatically selected according to the room temperature when the unit is turned on DRY MODE The fan speed is preset to AUTO and cannot be changed WHEN POWER FAILURE OCCURS This air conditioner has a memory function to stor...

Страница 8: ...n order to prevent condensation from dripping ADJUSTING THE AIR FLOW DIRECTION 1 2 Louvre levers The air conditioner works at the maximum power and optimum louvre direction to makes the room cool rapidly 1 During operation press the POWERFUL JET button The remote control will display The temperature display will go off The green POWERFUL JET lamp will light up The vertical airflow louvre will be s...

Страница 9: ... ions released into the room will reduce some airborne mold 1 During operation press the PLASMACLUSTER button The remote control will display The blue PLASMACLUSTER lamp will light up TO CANCEL Press the PLASMACLUSTER button again The blue PLASMACLUSTER lamp will turn off NOTE Use of the PLASMACLUSTER operation will be memorized and it will be activated the next time you turn on the unit To perfor...

Страница 10: ...ctivated press the ONE HOUR OFF TIMER button again during operation SELF CLEAN OPERATION SELF CLEAN operation will reduce the growth mold fungus with Plasmacluster ions and dry inside of the unit Utilize the operation at seasonal change over terms or every 4 months 1Press the SELF CLEAN button when the unit is not operating The remote control will display The blue PLASMACLUSTER lamp will light up ...

Страница 11: ...r increments The TIMER OFF and TIMER ON can not be set together The ONE HOUR OFF TIMER operation has priority over TIMER ON and TIMER OFF operations When the temperature is set during timer setting the temperature will show in the display for 5 sec onds and then return to the timer display If a power failure occurs while the TIMER is set the TIMER setting will be cancelled and will not be retrieve...

Страница 12: ... e h t r o will turn off TO LIGHT UP Press the DISPLAY button again DISPLAY BUTTON 1 OPERATING CONDITION Mode Indoor Temp Outdoor Temp Cooling Upper limit 32 C 43 C Lower limit 21 C 21 C The built in safety device may prevent the unit from operating when used out of this range Condensation may form on the air outlet if the unit operates continuously in the COOL or DRY mode when humidity is over 80...

Страница 13: ... THE UNIT AND THE RE MOTE CONTROL Wipe them with a soft cloth Do not directly splash or pour water on them It can cause electrical shock or equipment damage Do not use hot water thinner abrasive pow ders or strong solvents MAINTENANCE AFTER AIR CONDITIONER SEASON 1 Operate the unit in the SELF CLEAN operation to thoroughly dry inside the unit 2 Stop the operation and unplug the unit Turn off the c...

Страница 14: ...urned off The unit will not op erate immediately after the mode is changed This is to protect the unit Wait 3 minutes be fore operating the unit ODORS Carpet and furniture odors that entered into the unit may be sent out from the unit CRACKING NOISE This sound is generated by the friction of the unit expanding or connecting due to a tempera ture change A LOW BUZZING NOISE This is a sound of the un...

Страница 15: ...AH XPC9RV indd 13 11 8 8 1 33 37 PM ...

Страница 16: ...Printed in Thailand TINSEA845JBRZ 14B TH 1 AH XPC9RV indd 14 11 8 8 1 33 37 PM ...

Отзывы: