Please read ALL instructions before installing. Two people are

recommended to install this product. If a new electrical outlet

is required, have the outlet installed by a qualified electrician
before installing unit. See#5 in Preliminary Instructions

following.

Preliminary instructions

Do the following before starting to install unit. See illustrations
below.

with this air conditioner are made to install in a wooden

Check dimensions of your unit to determine model type:

1

.   

Check window opening size - 

the mounting parts furnished

sill double-hung window. The standard parts are for

window dimensions listed above. Open sash to a minimum

of 19"(483mm). (FIG. 1)

2

.   

Check condition of window - 

all wood parts of window

must be in good shape and able to firmly hold the needed

screws.If not, make repairs before installing unit.

3

.   

Check your storm windows - 

if your storm window

frame does not allow the clearance required, correct by

adding a piece of wood as shown in FIG.2, or by removing

storm window while room air conditioner is being installed.

(continued)

Unit Height:
Unit Width:

Min. Window Opening:

Min. Window Width:
Max. Window Width:

17.5/8"
23 

1

/

2

"

18 

1

/

2

"

26 

1

/

2

"

40 

1

/

2

"

FIG. 1

 

FIG. 2

SASH

19" MIN

1/2" MIN

STORM WINDOW FRAME OR

OTHER OBSTRUCTION

SASH

1/2" MIN

19" MIN

STORM WINDOW FRAME OR

OTHER OBSTRUCTION

1 1/2" MIN

BOARD THICKNESS AS

REQUIRED, ALONG

ENTIRE STOOL, FASTEN

WITH TWO NAILS OR

SCREWS.

SEAL-BOTTOM RAIL TO UNIT

SIDE RETAINER

FRAME

ASSEMBLY

(LEFT)

WASHER HEAD
LOCKING SCREW

FOAM GASKET

TOP ANGLE

FRAME

ASSEMBLY

(LEFT)

SAFETY LOCK AND
3/4" LONG HEX HEAD

SCREW

1/2" LONG 

SCREWS AND

LOCKNUTS

LOCKNUT

3/4" LONG 

FLAT HEAD

BOLT

WINDOW SUPPORT

BRACKET

WINDOW SASH SEAL

SILLANGLE
BRACKET

Содержание AF-S155NX

Страница 1: ...AF S155NX N ...

Страница 2: ......

Страница 3: ......

Страница 4: ... able to firmly hold the needed screws If not make repairs before installing unit 3 Check your storm windows if your storm window frame does not allow the clearance required correct by adding a piece of wood as shown in FIG 2 or by removing storm window while room air conditioner is being installed continued Unit Height Unit Width Min Window Opening Min Window Width Max Window Width 17 5 8 23 1 2 ...

Страница 5: ...ewdriver tape measure adjustable wrench or pliers pencil Level Socket wrenches Phillips screwdriver Tools Required Hardware in plastic bag 6 Carefully unpack air conditioner remove all packing material Protect floor or carpet from damage Two people should be used to move and install unit Avoidfirehazardorelectric shock Donotuseanextensioncordoran adaptorplug Donotremoveanyprongfrom thepowercord WA...

Страница 6: ...tainers to cabinet as shown in FIG 6 FIG 6 6 Remove shipping crews from top of unit and also on the side by the base if installed 7 Hold the cabinet while pulling on the base handle and care fully remove the unit 8 Add two foam inserts to holes in top of cabinet where shipping screws were removed from Assemble Window Filler Panels 1 Place cabinet on floor a bench or a table 2 Slide I section of wi...

Страница 7: ...window stool as shown Bring window down temporarily behind top angle to hold cabinet in place STOOL STOOL ANGLE LEFT LOCKNUT SILL ANGLE BRACKET FLAT HEAD BOLT 2 EACH REQ D FOR EACH SUPPORT BRACKET MARK 1 2 LONG SCREWS AND LOCKNUTS RIGHT 3 Shift cabinet left or right as needed to line up center of cabinet on center line marked on stool 4 Fasten cabinet to window stool with 2 screws into holes You m...

Страница 8: ... DO not push on controls OR finned coils screws Loosen screws so filler panels slide easily 2 Extend panels to fill window opening completely 3 Close window behind top angle Tighten locking screws on top 1 Trim sash seal to fit window width Insert into space between upper and lower sashes 2 Attach right angle safety lock as shown LOCKING SCREWS WINDOW SASH SEAL SAFETY LOCK 3 4 long hex head screw ...

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ...speeds will re adjust back to the slowest speed as the room returns to the original set temperature cally maintained anywhere between 60o F 16o C and 90o F 32o C for cooling mode If you want the display to read the actual room temperature Press the Fan Faster button will increase the fan speed from Low LO to Medium ME to High HI The digital display will indicate your chosen speed Press the Fan Slo...

Страница 13: ...ours The control will count down the time remaining until start 8 7 5 7 etc The Timer On mode automatically selects cooling with maximum Fan Speed The temperature maintained will be the same as previously set To change the set temperature press MODE then Up or Down arrows until the desired temperature is indicated on the display After 5 seconds the con trol will automatically change the display ba...

Страница 14: ...and draws fresh air into the room Vent and Exhaust Open see Fig 3 Fig 1 OFF Fig 2 FRESH AIR Fig 3 VENT AUGER WHEEL The louvers will allow you to direct the air flow Up or Down and Left or Right throughout the room as needed Rotate the Auger Wheel Up or Down until the desired direction is obtained 4 WAY FAULT CODES If the display reads ES or AS a sensor has failed Contact your Authorized SHARP Serv...

Страница 15: ......

Страница 16: ......

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...66129901273 ...

Отзывы: