This INSTALLATION AND OPERATION
MANUAL explains the proper use of your   new
Sharp Air Conditioner. Read these instructions
carefully before installing  or operating  your air
conditioner. The INSTALLATION  AND  OP-
ERATION  MANUAL   should be kept in a safe
place for handy reference.

FOR YOUR PROTECTION ....................

  2

CONSUMER LIMITED WARRANTY .....

  3

INSTALLATION INSTRUCTIONS

• CHECK WINDOW AREA ........................   4
• LOCATlON ..............................................   4
• ACCESSORIES ......................................   5
• SUGGESTED TOOLS ............................   5
• INSTALLATION .......................................   6

PRECAUTIONS

• 

CAUTION FOR USE ............................   8

• GROUNDING INSTRUCTIONS ...........   8
• NOTES ON OPERATION ....................   9
• ENERGY EFFICIENCY TIPS ...............   9

HOW TO OPERATE

• 

PARTS NAMES ................................... 10

• 

COOLING OPERATION ...................... 11

• TO CHANGE FAN SPEED AND OPERATION MODE .. 11
• TO CHANGE TEMPERATURE SETTING .......... 12
• TO CHANGE AIR FLOW DIRECTION ....... 12
• ENERGY SAVER OPERATION ........... 13
• SLEEP OPERATION ........................... 13
• ON TIMER OPERATION ..................... 14
• OFF TIMER OPERATION .................... 15
• USING THE REMOTE CONTROL ....... 16

CLEANING AND MAINTENANCE ........

18

BEFORE CALLING FOR SERVlCE ......

19

As an ENERGY STAR Partner, Sharp Electronics has determined that this product (AF-S80EX) meets the
ENERGY STAR guidelines for energy efficient air conditioners.  To meet these guidelines, air conditioners
must be at least 10% more efficient than the minimum Federal standard.

Содержание AF-R80EX

Страница 1: ...TION 6 PRECAUTIONS CAUTION FOR USE 8 GROUNDING INSTRUCTIONS 8 NOTES ON OPERATION 9 ENERGY EFFICIENCY TIPS 9 HOW TO OPERATE PARTS NAMES 10 COOLING OPERATION 11 TO CHANGE FAN SPEED AND OPERATION MODE 11 TO CHANGE TEMPERATURE SETTING 12 TO CHANGE AIR FLOW DIRECTION 12 ENERGY SAVER OPERATION 13 SLEEP OPERATION 13 ON TIMER OPERATION 14 OFF TIMER OPERATION 15 USING THE REMOTE CONTROL 16 CLEANING AND MAI...

Страница 2: ...DITIONAL CUSTOMER INFORMATION TO WRITE For service problems warranty information missing items and other assistance Sharp Electronics Corporation Customer Assistance Center 1300 Naperville Drive Romeoville IL 60446 1091 Please provide the following information when you write or call model number serial number date of purchase your complete mailing address including zip code your daytime telephone ...

Страница 3: ...ment of all liabilities and responsibilities of Sharp to the purchaser with respect to the Product and shall constitute full satisfaction of all claims whether based on contract negligence strict liability or otherwise In no event shall Sharp be liable or in any way responsible for any damages or defects in the Product which were caused by repairs or attempted repairs performed by anyone other tha...

Страница 4: ...377mm or more CHECK WINDOW AREA The air conditioner should be installed on a firm foundation to minimize noise and vibration For safe installation repairs replacement and secure positioning make sure the foundation is solid and level The room air conditioner must be installed in an area within reach of a properly rated grounded outlet Use of extension cords of any kind is not recommended Never pla...

Страница 5: ... foam seal 1 1 Screw driver medium size Phillips 2 Tape measure or ruler 3 Knife or scissors INSTALLATION INSTRUCTIONS SUGGESTED TOOLS Window sash foam seal 1 adhesive type Bottom gasket 1 Screws L 1 25 4mm 7 Screws L 13 32 10mm 6 Base pan angle 2 Remote control 1 Battery 2 1 2 3 4 5 6 7 8 9 10 7 6 9 8 10 ...

Страница 6: ...m channel and the sill fill the gap with a thin board or other hard filler INSTALLATION INSTRUCTIONS Closure assembly Bottom gasket Cut the window sash foam seal adhesive type to the proper length and attach it to the underside of the window sash 1 WARNING Make sure the unit is turned off and unplugged before working Sash Jamb Sill Window sash foam seal adhesive type WARNING unit sill incline back...

Страница 7: ...roper length and seal the opening be tween the top of the inside window sash and the outside window sash 6 INSTALLATION INSTRUCTIONS Top angle Window sash foam seal Secure the base pan angle to the sill by using the hole of the front side on the angle with one screw L 1 25 4mm Loosen screws on both sides of the cabinet then hang the base pan angle on and secure the screws again Insert the closure ...

Страница 8: ...pliances WARNING Improper use of the grounding plug can result in the risk of electric shock This appliance must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current This appliance is equipped with a cord having a grounding wire with a grounding plug The plug must be plugged into an outlet that is ...

Страница 9: ...Y TIPS Setting the proper temperature For optimum energy efficiency keep the difference between the inside and outside temperature within 10 F 5 C Do not keep the temperature setting any lower than is necessary for you to feel comfortable Generally 78 F to 80 F 26 C to 27 C is a comfortable summer indoor temperature When you turn the unit on do not set the temperature higher than the room temperat...

Страница 10: ...le Power Cord HOW TO OPERATE 7 8 9 10 6 5 4 3 2 1 11 1 2 3 4 5 6 7 8 9 10 11 1 2 hr F POWER ON OFF ENERGY TIMER SAVER ON OFF SELECTOR TEMP COOL SLEEP 3 4 5 8 10 12 7 9 11 6 Receiver window for remote control signal Display SLEEP indicator SELECTOR pad COOL indicator TEMPERATURE setting pad Lower temp Raise temp TIMER ON OFF pad TIMER indicator ENERGY SAVER pad ENERGY SAVER indicator POWER ON OFF p...

Страница 11: ... OPERATION TO CHANGE FAN SPEED AND OPERATION MODE During operation Touch SELECTOR pad and select the operation mode and fan speed Fan speed and operation mode will change as you touch NOTES ON OPERATION MODE COOL indicator DISPLAY HIGH COOL MED COOL LOW COOL HIGH FAN MED FAN LOW FAN When the SELECTOR is changed to fan only operation from cooling operation it will take 5 seconds for the compressor ...

Страница 12: ...and display will return to the preset conditions of 74 F and HIGH COOL The unit will not automatically turn back on The user must touch POWER ON OFF to resume operation During cooling operation TO CHANGE TEMPERATURE SETTING Raise temp hr F POWER ON OFF ENERGY TIMER SAVER ON OFF SELECTOR TEMP COOL SLEEP TEMPERATURE setting pad TO CHANGE AIR FLOW DIRECTION Horizontal louvers Adjust UP DOWN air flow ...

Страница 13: ...ill light SLEEP OPERATION When SLEEP OPERATION is set the temperature setting is automatically adjusted to prevent the room from becoming too cold while you sleep One hour after the SLEEP OPERATION is started the temperature setting rises 2 F higher than the original temperature setting The temperature will return to its original setting after 8 hours 2 To cancel press the SLEEP but ton again SLEE...

Страница 14: ... The temperature setting will be displayed This unit has a built in timer that can be programmed to start the unit up to 12 hours in advance You can set the timer to start in increments of 30 minutes 0 5 hours up to 9 5 hours in advance of the start time or in 1 hour increments from 10 to 12 hours in advance of the start time The unit will start automatically according to your setting When the uni...

Страница 15: ... the delay time as shown above TO CANCEL THE TIMER SETTING Touch the TIMER ON OFF pad again after the timer is set or press the TIMER ON OFF pad until CL cancel appears on the display When the unit is operating 0 5h 1 0h 1 5h 10h Preset 0 5h Previous setting 11h 12h CL cancel NOTES FOR ON OFF TIMER SETTING AND OPERATION After setting the TIMER change the temperature and fan speed settings as shown...

Страница 16: ...block the receiver window The remote control operates from up to 20 feet 6 meters away The beep will also sound when each pad on the control panel is touched CAUTION Do not expose the receiver window to direct sunlight This can adversely affect its operation In such case close the curtains to block the sunlight Use of a fluorescent lamp in the same room may interfere with the transmission of the s...

Страница 17: ...IMER button is pushed for the last time If you wish to cancel the timer push the OFF TIMER button again after the time is set or push the OFF TIMER button until CL cancel appears on the display A double beep will sound when the timer is cancelled The ON TIMER cannot be set with the remote control It can only be activated by the TIMER ON OFF pad on the unit s control panel See page 14 SLEEP button ...

Страница 18: ... OILING OF THE COMPRESSOR AND FAN MOTOR IS UNNECESSARY The compressor is permanently lubricated and is hermetically sealed The fan motor is lifetime sealed and does not require oiling 2 3 REMOVE THE FILTER Gently pull the filter handle to the right and slide the filter out from the unit CLEAN THE FILTER To remove dust from the filter use a vacuum cleaner or wash it in clean water If the filter is ...

Страница 19: ...the room Are the windows or doors open Close all windows and doors for maximum cooling TIMER DOES NOT WORK PROPERLY If a power failure occurs while the ON or OFF TIMER is set the TIMER setting will be cancelled and will not resume even after the power is reinstated This is the normal operation for this unit NOTE WATER IN BOTTOM OF TRAY Water will collect in the bottom tray of the unit This is norm...

Страница 20: ...SHARP ELECTRONICS CORPORATION Sharp Plaza Mahwah New Jersey 07430 2135 SHARP CORPORATION Osaka Japan Printed in Thailand TINSEA360JBRZ 03JO TH 1 ...