Sharp AF-R100CX Скачать руководство пользователя страница 9

9

PRECAUTIONS

• Allow 3 minutes for the compressor to restart cooling.

If you turn the air conditioner off and immediately restart it, allow three minutes for the compressor to
restart cooling. There is an electronic device in the unit that keeps the compressor off three minutes for
protection.

• If a power failure occurs during use, allow 3 minutes before restarting the unit.

After power is reinstated, restart the air conditioner. If the power was off for less than three minutes, be
sure to wait at least three minutes before restarting the unit. If you restart the air conditioner within three
minutes, a protective device in the unit may cause the compressor to shut off. This protective device will
prevent cooling for about 5 minutes.
Memories of previous settings will be canceled and the unit will return to each initial setting.

• Dehumidifying function

The air conditioner removes moisture from the air in your room.

• Cooling operation under low temperatures: Is your unit freezing up?

The unit operates on inside and outside temperatures. Freezing can occur when  the temperature is set
close to 64

°

F and when there are low outside  temperatures, especially during the night hours. At these

conditions, a further temperature drop may cause the unit to freeze. Setting the unit to a higher
temperature will prevent it from freezing.

NOTES ON OPERATION

ENERGY EFFICIENCY TIPS

Setting the proper temperature.

For optimum energy efficiency, keep the difference between the inside and outside temperature within
10

°

F(5

°

C). Do not keep the temperature setting any lower  than  is  necessary for you to feel comfortable.

Generally, 78

°

F to 80

°

F(26

°

C to 27

°

C) is a comfortable summer indoor temperature.

When you turn the unit on, do not set the temperature higher than the room temperature at start up as
this will not allow  the  compressor to cycle and maintain a comfortable room temperature.

Avoid direct sunlight.

Close blinds, drapes or shades to keep out direct sunlight during cooling operation.

Keep the filter clean.

Keeping the filter clean greatly aids efficient operation. A dirty filter blocks the  flow of air, making your air
conditioner work harder and less efficiently. See page 18 on how to clean the filter.

Turn off unnecessary light.

Your air conditioner must remove the heat produced by your lights or other  heat-producing appliances.
Turn off lights or appliances that are not in use.

Install your air conditioner in a shady location.

Direct sunlight on a window air conditioner increases its workload and will increase its operating cost.

Don't let cool air escape.

Close windows and outside doors. Do not keep doors open and let hot air  rush in. Improperly installed
air conditioners and improperly weatherstripped  doors  and windows will let hot air in and the cool air out.

Turn off air conditioner when no one is home.

Use only when necessary. The fewer hours a room air conditioner is used, the lower the operating cost.

Содержание AF-R100CX

Страница 1: ... WARRANTY 3 INSTALLATION INSTRUCTIONS CHECK WINDOW AREA 4 LOCATlON 4 ITEMS PACKED WITH THlS UNIT 5 SUGGESTED TOOLS 5 INSTALLATION 5 PRECAUTIONS CAUTION FOR USE 8 GROUNDING INSTRUCTIONS 8 NOTES ON OPERATION 9 ENERGY EFFICIENCY TIPS 9 HOW TO OPERATE PARTS NAMES 10 COOLING OPERATION 11 TO CHANGE TEMPERATURE SETTING 11 TO CHANGE FAN SPEED 12 FAN ONLY OPERATION 12 ENERGY SAVER 13 TO CHANGE AIR FLOW DIR...

Страница 2: ...cer PARTS for your Authorized Parts Distributor ACCESSORIES ADDITIONAL CUSTOMER INFORMATION TO WRITE For service problems warranty information missing items and other assistance Sharp Electronics Corporation Customer Assistance Center 1300 Naperville Drive Romeoville IL 60446 1091 Please provide the following information when you write or call model number serial number date of purchase your compl...

Страница 3: ...f all liabilities and responsibilities of Sharp to the purchaser with respect to the Product and shall constitute full satisfaction of all claims whether based on contract negligence strict liability or otherwise In no event shall Sharp be liable or in any way responsible for any damages or defects in the Product which were caused by repairs or attempted repairs performed by anyone other than an a...

Страница 4: ...0mm 1 32 5 32 Window opening from stool to lower sash bottom must be 16 407mm or more 1 32 CHECK WINDOW AREA LOCATION The air conditioner should be installed on a firm foundation to minimize noise and vibration For safe installation repairs replacement and secure positioning make sure foundation is solid and level The room air conditioner must be installed in an area within reach of a properly rat...

Страница 5: ...oam seal adhesive type to the proper length and attach it to the underside of the window sash 2 Attach the bottom gasket to the outer side of the window sill 1 These models can also be installed through the wall with the optional through the wall mounting kit model AZ 80WK To order this kit either contact your dealer or call 1 800 BE SHARP The wall opening dimensions for through the wall installat...

Страница 6: ...f the cabinet is not properly inclined the water collected in the bottom tray during operation will not drain properly and may flow into the room where the air conditioner is installed 1 2 Unscrew the 2 screws at the corners of the front panel Keep them as they will be used later Remove the front panel by pulling the front panel at the lower corners towards you about an inch Next lift it up and pu...

Страница 7: ...s L 1 25 4 mm 1 7 9 Replace the front panel Slip the ex haust lever through the opening between the horizontal louver and the front panel then hook the cabinet top 1 Window sash foam seal 2 3 8 Slide the chassis back into the cabinet Replace the 4 screws removed in step 3 to the top and side of the cabinet 1 2 CAUTION 2 Cut the window sash foam seal to the proper length and seal the opening be twe...

Страница 8: ...sary that it be a UL Listed 3 wire grounding type appliance extension cord rated 125 Volts 15 amp or more Ventilate the room periodically during use especially if using gas appliances WARNING Improper use of the grounding plug can result in the risk of electric shock This appliance must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providin...

Страница 9: ...FICIENCY TIPS Setting the proper temperature For optimum energy efficiency keep the difference between the inside and outside temperature within 10 F 5 C Do not keep the temperature setting any lower than is necessary for you to feel comfortable Generally 78 F to 80 F 26 C to 27 C is a comfortable summer indoor temperature When you turn the unit on do not set the temperature higher than the room t...

Страница 10: ...R indicator PARTS NAMES UNIT CONTROL PANEL TEMPERATURE setting pad Lower temp Raise temp ENERGY SAVER pad ENERGY SAVER indicator POWER ON OFF pad POWER indicator OPERATION INSTRUCTIONS 6 5 4 3 2 1 7 11 10 9 8 Front panel Air inlet Indoor side Louvers Air outlet Indoor side Exhaust lever Control panel Cabinet Air outlet Outdoor side Air inlet Outdoor side Filter Pull the filter handle to the right ...

Страница 11: ... range of 64 F to 86 F Display will change as you touch the pad The latest temperature setting will be memorized and will appear on the display the next time the unit is turned on NOTE In cases of power outages or when the unit is disconnected when the power is restored or the unit is plugged in the unit and display will return to the preset conditions of 74 F and HIGH COOL The unit will not autom...

Страница 12: ...used to circulate air whenever cooling is not desired The fan will operate at medium speed Procedure Display Indicator Pad SELECTOR indicator FAN ONLY will light and the tem perature display will go off After 5 seconds the com pressor will stop and the unit will operate in FAN ONLY mode When the unit is turned off the last fan speed will be stored in memory The next time the air conditioner is use...

Страница 13: ... to detect room temperature Procedure Pad 2 To cancel touch ENERGY SAVER pad again ENERGY SAVER indicator will light ENERGY SAVER indicator will go off NOTE ENERGY SAVER cannot be set during FAN ONLY mode operation Display Indicator During cooling operation 1 Touch ENERGY SAVER pad Adjust the louvers to change the direction of air flow for uniform and efficient cooling of the room Vertical louvers...

Страница 14: ...ht The time display will count down the remaining time The unit will start when the set time expires The temperature setting will be displayed If you wish to start the op eration 6 hours and 30 min utes later set the delay time as shown below 1Touch the TIMER ON OFF pad to set the delayed start time The unit is preset to 0 5 hours 30 minutes This unit has a built in timer that can be programmed to...

Страница 15: ...splay 1 Touch the TIMER ON OFF pad to set the delayed stop time SELECTOR indicator and TIMER indicator will light If you wish to stop the op eration 10 hours later set the delay time as shown below After setting the OFF TIMER change the temperature and fan speed settings as shown on pages 11 and 12 When the temperature is set in the timer mode the temperature will show in the display for 5 seconds...

Страница 16: ...nt Panel Remote control hook Cabinet HOW TO USE THE REMOTE CONTROL Point the remote control towards the unit s re ceiver window and press the desired button A beep will sound when the unit receives the signal Make sure no objects such as curtains block the receiver window The remote control operates from up to 20 feet 6 meters away The beep will also sound when each pad on the control panel is tou...

Страница 17: ...setting 1 F at a time POWER TEMP TEMP SELECTOR SET TIMER OFF ON OFF HOW TO OPERATE OPERATING WITH THE REMOTE CONTROL TRANSMITTER TEMPERATURE setting button POWER ON OFF button SELECTOR button Push to start or stop the operation Push to change fan speed or to select fan only mode Fan speed selections are shown to the right SET TIMER OFF button Push to set delay OFF timer during operation To Change ...

Страница 18: ...it in direct sunlight RE INSTALL THE FILTER Align the filter behind the front panel Grasp the filter handle and gently push the filter back into place Never operate the unit without installing the filter It may result in serious damage to the unit 1 CLEANING OF THE FRONT PANEL AND CABINET To clean the front panel and cabinet wipe with a soft dry cloth or with a cloth moistened with a mild soap Rin...

Страница 19: ...inds to minimize solar energy heating the room Are the windows or doors open Close all windows and doors for maximum cooling TIMER DOES NOT WORK PROPERLY If a power failure occurs while the ON or OFF TIMER is set the TIMER setting will be cancelled and will not resume even after the power is reinstated This is the normal operation for this unit NOTE WATER IN BOTTOM OF TRAY Water will collect in th...

Страница 20: ...20 SHARP ELECTRONICS CORPORATION Sharp Plaza Mahwah New Jersey 07430 2135 SHARP CORPORATION Osaka Japan Printed in Thailand TINSEA297JBRZ 01LO TL 1 ...