2
Air inlet
Air outlet
57.0~58.0 cm
(22.4"
~22.8"
)
8~25 cm(3"~9.8")
38.5~39.5 cm
(15.2"~15.6")
More than 20 cm
(8")
More than 20 cm(8")
48.0~49.0 cm
(18.9"
~19.3"
)
8~25 cm(3"~9.8")
36.0~37.0 cm
(14.2"~14.6")
More than 20 cm
(8")
More than 20 cm(8")
LOCATION
Install the air conditioner to the opening dimensions shown below.
Never place any obstacles around the air inlet and outlet.
The air conditioner should be installed with a strong external support to minimize noise and
vibration, and for the purpose of safe installation, repair, replacement and secure positioning.
Avoid installing the air conditioner where it is exposed to direct sunlight.
AF-A077J,AF-A097J
AF-A127J
More than 40cm(16")
More than 20cm(8")
Air inlet
Air outlet
Air inlet
More than 40cm
(16")
About 1cm
(3/8")
Tilt the unit slightly to the back to allow
water to drain from the unit.
This air conditioner complies with the requirements of AS 3179: 1993 and must be
installed to comply with AS 3000.
EARTH INSTRUCTIONS
WARNING : THIS APPLIANCE MUST BE EARTHED.
This appliance is equipped with a cord having a earth wire with
a 3 pin plug. The plug must be plugged into an outlet that is
properly installed and earthed.
Do not cut or remove the earth pin from this plug under any
circumstances.
FUSE
For safe, trouble free operation, connect the power
cord of the unit to a properly rated independent circuit
with a time delay fuse or a circuit breaker. See chart
for proper amp ratings for each model.
3 pin earth plug
Earth pin
AF-A077J, AF-A097J
AF-A127J
10 amp
15 amp
INSTALLATION INSTRUCTIONS
AF-A077J 2çZ-2
98.1.6, 0:11 PM
3