AE-XM30GR
4 – 2
3. Cycle temperature and pressure in stop valve (AE-XM30GR)
Standard conditions (AE-XM30GR)
Running unit
no operation mode
Cool (MAX)
Cool (Test run)
Heat (MAX)
Heat (Test run)
AY-XPM9FR &
AY-XPM7FR &
AY-XPM7FR &
AY-XPM7FR
(4 units)
(1)
94
80
77
55
(2)
40
36
15
6
(3)
11
13
29
25
(4)
13
16
-3
6
stop valve (gas side)
0.92MPa(abs)
1.1MPa(abs)
2.53MPa(abs)
1.93MPa(abs)
Frequency
80Hz
50Hz
90Hz
38Hz
GS-XPM18FGR
(1)
92
77
91
70
(2)
37
36
19
8
(3)
9
11
38
34
(4)
10
16
3
6
stop valve pressure
0.83MPa(abs)
1.03.MPa(abs)
3.58MPa(abs)
2.57MPa(abs)
Frequency
Frequency
62Hz
35Hz
72Hz
38Hz
AY-XPM12FR
(1 unit)
(1)
83
76
82
62
(2)
36
35
13
6
(3)
10
13
43
7
(4)
11
19
4
7
stop valve pressure Frequency
0.86
MPa (abs)
1.07MPa (abs)
3.15MPa (abs)
2.37MPa (abs)
Frequency
41Hz
23Hz
50Hz
25Hz
AY-XPM9FR
(1 unit)
(1)
78
69
83
58
(2)
36
35
12
6
(3)
9
11
36
24
(4)
13
19
5
7
stop valve pressure Frequency
0.94MPa (abs)
1.11.MPa (abs)
3.20MPa (abs)
2.21MPa (abs)
Frequency
31Hz
30Hz
45Hz
20Hz
AY-XPM7FR
(1 unit)
(1)
74
69
75
59
(2)
35
35
10
6
(3)
9
11
32
24
(4)
16
19
6
7
stop valve pressure Frequency
0.99MPa (abs)
1.09.MPa (abs)
3.00MPa (abs)
2.24MPa (abs)
Frequency
24Hz
17Hz
35Hz
20Hz
indoor side
Outdoor side
Dry-bulb temp. (
C)
Relative humidity (%)
Dry-bulb temp. (
C)
Relative humidly (%)
Cooling
27
47
35
40
Heating
20
–
7
87
INDOOR UNIT
OUTDOOR UNIT (AE-XM30GR)
UNIT D
UNIT C
UNIT B
UNIT A
Cooling
heating
Содержание AE-XM30GR
Страница 39: ......