ENGLISH
MAINTENANCE
Be sure to turn off the air conditioner and turn off the circuit breaker before perform-
ing any maintenance.
MAINTENANCE AFTER AIR
CONDITIONER SEASON
1
Operate the unit in the COOL
mode, temperature setting 32°C,
for about half a day to allow the
mechanism to thoroughly dry.
2
Stop the operation.
Turn off the circuit breaker, if you
have one exclusively for the air
conditioner.
3
Clean the filters, then reinstall
them.
MAINTENANCE BEFORE
AIR CONDITIONER SEASON
1
Make sure that the air filters are
not dirty.
2
Make sure that nothing obstructs
the air inlet or outlet.
3
Check the outdoor mounting rack
periodically for wear and to make
sure it is firmly in place.
1
TURN OFF THE UNIT
2
REMOVE THE FILTERS
1 Lift the open panel.
2 Push the air filters up slightly to unlock them.
3 Pull the air filters down to remove them.
3
CLEAN THE FILTERS
Use a vacuum cleaner to remove dust. If the
filters are dirty, wash them with warm water
and a mild detergent. Dry filters in the shade
before reinstalling.
4
REINSTALL THE FILTERS
1 Reinstall the filters in the original positions.
2 Close the front panel.
3 Push the arrow-marked of the panel firmly
to lock it in place.
CLEANING THE FILTERS
The air filters should be cleaned every two weeks.
CLEANING THE UNIT AND THE REMOTE CONTROL
• Wipe them with a soft cloth.
• Do not directly splash or pour water on them. We can cause electrical shock or
equipment damage.
• Do not use hot water, thinner, abrasive powders or strong solvents.
(for models AY-XM7CR/AY-XM9CR/AY-XM12CR)
1
2
3
3
1
2
E-19