Flow of Refrigerant
1. Cycle temperature and pressure in stop valve
Running unit
No
Operation Mode
Cool (MAX)
Cool (Test run)
Heat (MAX)
Heat (Test run)
AY-XPM7FR &
AY-XPM7FR &
AY-XPM7FR
(3 units)
(1)
86
70
78
50
(2)
45
41
-1
2
(3)
12
15
35
27
(4)
15
19
0
3
Stop valve pressure (gas side)
1.04MPa(abs)
1.21MPa(abs)
2.53MPa(abs)
1.97MPa(abs)
Frequency
100Hz
70Hz
120Hz
50Hz
AY-XPM12FR
(1 unit)
(1)
80
67
89
59
(2)
38
37
1
3
(3)
10
13
42
25
(4)
11
17
2
6
Stop valve pressure Frequency
0.88MPa (abs)
1.10MPa (abs)
3.52MPa (abs)
2.38MPa (abs)
Frequency
70Hz
40Hz
90Hz
40Hz
Heat
exchanger
Heat exchanger
Heat exchanger
UNIT C
UNIT B
UNIT A
STOP valve (Liquid)
Compressor
4-way
valve
Accumulator
STOP valve (Gas)
Expansion valve C
Expansion valve B
Expansion valve A
(1)
(4)
(2)
(3)
(3)
(3)
Heat exchanger
INDOOR UNIT
OUTDOOR UNIT
INDOOR UNIT
OUTDOOR UNIT
UNIT C
UNIT B
UNIT A
Cooling