13

1

TIMER ON

NOTES FOR TIMER SETTING AND OPERATION

• The latest time setting will be memorized and will appear on the remote control display the next

time you set the TIMER OFF or TIMER ON.

• TIMER OFF and TIMER ON can not be set together.

The latest set TIMER will be active.

• When ONE-HOUR OFF TIMER is set, TIMER OFF and TIMER ON will not be available.
• When ONE-HOUR OFF TIMER is set during TIMER OFF or TIMER ON duration, the  TIMER ON

or TIMER OFF will be cancelled.

Example : When you wish the

room temperature

to be as desired

6.5 hours later.

MODE

DISPLAY MODE

FAN

1h

SWING CANCEL

TEMP.

TEMP.

FAN

TIMER

The unit will turn on automatically according to your setting.
Timer duration can be set from minimum 0.5 hours (30 minutes) to maximum 12
hours.
Up to 9.5 hours, you can set by 0.5 hours (30 minutes) increments and from 10 to 12
hours, by 1 hour increment.

Point the remote control at the signal reciever win-
dow on the unit.

1

Press the TIMER ON ( 

 ) button.

• The time setting will change as you press the button

as follows.

Hold the button pressed down for fast setting.

• The orange TIMER lamp ( 

 ) on the unit will light.

• The unit will generate a beep when it receives the

signal.

• The time setting will count down to show remaining

time.

Select the mode, temperature, fan speed setting
and PLASMACLUSTER operation as desired.

• When the temperature is set with the TIMER ON,

the temperature will show in the display for 5 sec-
onds and then return to the time display.

• If you do not change the setting, the unit will oper-

ate with the latest setting.

• The unit will turn on prior to the set time to allow

the room to reach the desired temperature by the
programmed time. (Awaking function)

0.5h

1.0h

1.5h

10h

11h

12h

Содержание AE-A18EJ

Страница 1: ...AP24EJ AY AP18EJ AY AP24EJ AE A18EJ AE A24EJ R INDOOR UNIT SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL OUTDOOR UNIT Plasmacluster is a trademark of Sharp Corporation Uses ozone layer friendly refrigerant R410A ...

Страница 2: ......

Страница 3: ...an result in injury due to the high speed rotation of the internal fans 5 If anything abnormal with the air conditioner eg burning smell stop the opertaion immediately and turn the circuit breaker off 6 This air conditioner should be installed by a licensed air conditioning contractor in accordance with AS NZS 3000 2000 and your electricity suppliers rules 7 There are local council rules regarding...

Страница 4: ...t block the air inlets or outlets of the unit 7 For safety be sure to turn the unit off the circuit breaker before performing any maintenance or cleaning 8 Do not pour water directly on the unit Water can cause electrical shock or equipment failure 9 This appliance is not intended for use by young children or infirm persons without supervision Young children should be supervised to ensure that the...

Страница 5: ...ciency is reduced due to low outside temperatures use an additional heater It takes time to warm up and heat the entire room because of the forced air circulation system TIPS ON SAVING ENERGY Below are some simple ways to save energy when you use your air conditioner SET THE CORRECT TEMPERATURE Setting the thermostat 1 C higher than the desired temperature in the COOL mode and 2 C lower in the HEA...

Страница 6: ...tment Louvres 0 Horizontal Adjustment Louvres q Outlet Air w Remote Control e AUTO FAN SPEED Lamp green r FAN SPEED Lamp green t PLASMACLUSTER Lamp blue green y TIMER Lamp orange u OPERATION Lamp red OUTDOOR UNIT NOTE Actual units might vary slightly from those shown above INDOOR UNIT 1 2 3 4 5 6 7 8 9 0 q w i Inlet Air o Refrigerant Tube and Interconnecting Cord p Drainage Hose a Outlet Air 4 e r...

Страница 7: ...0 FAN Button q TIMER CANCEL Button w SWING Button e PLASMACLUSTER Button 5 r MODE SYMBOLS AUTO COOL HEAT DRY FAN ONLY t FAN SPEED SYMBOLS AUTO Manual setting y PLASMACLUSTER SYMBOL u TEMPERATURE AND TIMER COUNT DOWN INDICATOR i TRANSMITTING SYMBOL o TIMER ON TIMER OFF INDICATOR Indicates when timer on or timer off is set L C D REMOTE CONTROL DISPLAY 1 2 3 4 5 6 7 8 9 0 q w e r t y u i o MODE DISPL...

Страница 8: ... polarities are correctly aligned Lines will be indicated on the display when batteries are properly installed 3 Replace the battery cover USING THE REMOTE CONTROL 6 NOTES The battery life is approximately one year in normal use When you replace the batteries always change both batteries and make sure they are the same type If the remote control does not operate properly after replacing the batter...

Страница 9: ...natural environment In this operation mode negative ions will be released in an increased rate in order to bring the room air close to this condition Please refer to page 11 for operation The Plasmacluster ion generator inside the air conditioner will release Plasmacluster ions which are collective mass of positive and negative ions into the room The Plasmacluster ions reduce airborne mold fungus ...

Страница 10: ...1 8 BASIC OPERATION 2 Press the ON OFF button to start op eration The red OPERATION lamp on the unit will light 3 4 1 4 5 2 3 Press the MODE button to select the operation mode AUTO HEAT COOL DRY FAN ONLY 5 MODE DISPLAY MODE FAN 1h SWING CANCEL TEMP TEMP FAN TIMER Press the FAN button to set the de sired fan speed AUTO SOFT LOW HIGH In the DRY mode the fan speed is pre set to AUTO and cannot be ch...

Страница 11: ...t is turned on Modes and Temperature Settings Room temp at opera tion start up TIPS ABOUT FAN SPEED LAMP During opration the FAN SPEED Lamp will light up in 3 levels 2 levels for DRY mode on the indicator panel of the unit to indicate the fan speed When fan speed is set to AUTO When fan speed is set to manual Soft speed Low speed High speed The AUTO FAN SPEED Lamp will light up To turn off the FAN...

Страница 12: ...the SWING button again when the vertical adjustment lou vre is at the desired position The louvre will stop moving within the range shown in the diagram The adjusted position will be memorized and will be automati cally set to the same position when operated the next time Adjustment range HORIZONTAL AIR FLOW DIRECTION CAUTION Never attempt to adjust the vertical adjustment louvres manually Manual ...

Страница 13: ...FF TIMER button again during operation PLASMACLUSTER OPERATION 1 During operation press the PLASMACLUSTER button to select the mode AIR CLEAN ION BALANCE CANCEL In the AIR CLEAN operation the blue PLASMACLUSTER lamp on the unit will light up In the ION BALANCE operation the green PLASMACLUSTER lamp on the unit will light up TO CANCEL Press the PLASMACLUSTER button until PLASMACLUSTER symbol on the...

Страница 14: ...mostat setting TIPS ABOUT TIMER OFF OPERATION Point the remote control at the signal receiver win dow on the unit 1 Press the TIMER OFF button and set time as desired The time setting will change as you to press the button as follows Hold the button pressed down for fast setting The orange TIMER lamp on the unit will light The unit will generate a beep when it receives the signal The time setting ...

Страница 15: ... Up to 9 5 hours you can set by 0 5 hours 30 minutes increments and from 10 to 12 hours by 1 hour increment Point the remote control at the signal reciever win dow on the unit 1 Press the TIMER ON button The time setting will change as you press the button as follows Hold the button pressed down for fast setting The orange TIMER lamp on the unit will light The unit will generate a beep when it rec...

Страница 16: ... down both hooks at the left and right and release the lock 3 Pull out the louvre unit forward 4 Let it open downward gently 3 CLEAN THE INTERIOR OF THE AIR CONDI TIONER UNIT Make sure the fan inside is not rotating Remove the dust using a vacuum cleaner or wipe with dry cloth 4 CLOSE THE LOUVRE UNIT 1 Lift up the louvre unit and slide it back into its position 2 Make sure both hooks at the left a...

Страница 17: ...inlet or outlet 3 Check the outdoor mounting rack periodically for wear and to make sure it is firmly in place MAINTENANCE 1 2 3 2 3 1 The air filters should be cleaned every two weeks 1 TURN OFF THE UNIT 2 REMOVE THE FILTERS 1 Lift the open panel 2 Push the air filters up slightly to unlock them 3 Pull the air filters down to remove them 3 CLEAN THE FILTERS Use a vacuum cleaner to remove dust If ...

Страница 18: ...d doors are closed tightly A large number of people in the room can prevent the unit from achieving the desired temperature Check whether any heat generating appliances are operating in the room ODORS Carpet and furniture odors that entered into the unit and the air conditioner s inner component odors at the early stage of installation may be sent out from the unit SWISHING NOISE The soft swishing...

Страница 19: ...door unit AY AP18EJ AY AP24EJ Outdoor unit AE A18EJ AE A24EJ Rated A C voltage V 230 240 230 240 Rated freuency Hz 50 50 Cooling capacity kW 5 2 6 6 Heating capacity kW 5 7 8 1 When tested in accordance with AS NZS3823 1 1 ...

Страница 20: ...SHARP CORPORATION OSAKA JAPAN TINSEA392JBRZ 04GO TH 1 Printed in Thailand ...

Отзывы: