3
AH/AY-AP18DR
AH/AY-AP24DR
ITEMS
INDOOR UNIT
OUTDOOR UNIT
INDOOR UNIT
OUTDOOR UNIT
AH-AP18DR
AU-A18DR
AH-AP24DR
AU-A24DR
Cooling capacity
kW
5.2
6.7
Moisture removal
Liters/h
1.6
2.2
Electrical data
Phase
–
Single
Rated frequency
Hz
50
Rated voltage
V
220 – 240
Rated current
A
9.2 – 9.3
12.7 – 13.1
Rated input
kW
1.99 – 2.15
2.62 – 2.76
Rated factor
%
98 – 96
94 – 88
Compressor
Type
Hermetically sealed rotary type
Model
5KS225DAA
5JS315DAB
Oil charge
470cc [RB68A or Freol AlPha 68M]
700cc [RB68A or Freol AlPha 68M]
Refrigerant system
Evaporator
Louver fin and Grooved tube type
Condenser
Louver fin and Grooved tube typ
Control
Capillary tube
Refrigerant volume (R-410A)
910g
1380g
De-lce system
Micro computer controled reverse sysetm
Noise level
High
dB(A)
41
52
45
54
(at cooling)
Med.
dB(A)
36
–
39
–
Low
dB(A)
34
–
37
–
Fan system
Drive
Direct drive
Air flow quantity
High
m
3
/min.
15.7
48
18.3
46
(at cooling)
Med.
m
3
/min.
13.9
–
14.7
–
Low
m
3
/min.
11.7
–
13.5
–
Fan
Cross flow fan
Propeller fan
Cross flow fan
Propeller fan
Connections
Refrigerant coupling
Flare type
Refrigerant tube size Gas, Liquid
1/2", 1/4"
Drain piping mm
O.D ø 20
Others
Safety device
Compressor: Internal protector
Compressor: Internal protector
Fan motors: Thermal protector(Internal)
Fuse, Micro computer control
Air filters
Polypropylene net (Washable)
Net dimensions
Width
mm
1040 (1155)
890 (1020)
1040 (1155)
890 (1020)
(Cartont dimensions)
Height
mm
325 (300)
645 (735)
325 (300)
645 (735)
Depth
mm
220 (385)
327 (398)
220 (385)
327 (398)
Net weight (Gross weight)
kg
16 (21)
51 (55)
16 (21)
60 (64)
Note: The condition of star ( ) marked item are ‘ISO5151:1994(E), condition T1’.