70GS-61SC
DESCRIPTION OF SCHEMATIC DIAGRAM
SAFETY NOTE:
1. DISCONNECT THE AC PLUG FROM THE AC
OUTLET BEFORE REPLACING PARTS.
2. SEMICONDUCTOR HEAT SINKS SHOULD BE
REGARDED AS POTENTIAL SHOCK HAZARDS
WHEN THE CHASSIS IS OPERATING.
NOTE:
1. The unit of resistance «ohm»is omitted (K=1000
ohms. M= Megaohm).
2. All resistors are 1/8 watt. unless otherwise noted.
3. All capacitors are mF, unless otherwise noted
(P= mmF).
4. The capacitor with Part No. RC-FZ9XXXBMNJ
is designed to with stand 63V.
5. The capacitor with Part No. RC-FZ4XXXBMNJ
is designed to with stand 50V.
SERVICE PRECAUTION:
THE AREA ENCLOSED BY THIS LINE ( )
IS DIRECTLY CONNECTED WITH AC MAINS
VOLTAGE.
WHEN SERVICING THE AREA, CONNECT AN
ISOLATING TRANSFORMER BETWEEN TV
RECEIVER AND AC LINE TO ELIMINATE HAZ-
ARD OF ELECTRIC SHOCK.
WAVEFORMS MEASUREMENT:
1. TEST EQUIPMENT: Digital Oscilloscope (Tektronix TDS 3012).
2. TEST CONDITIONS: PAL B/G full colour bar, 1KHz sinewave (volume regulation 50%).
Note: Waveforms 8 and 11 should be taken with the TV set in Stand-by mode.
Red in
1
Green in
2
Blue in
3
IMPORTANT SAFETY NOTE:
PARTS MARKED WITH «
» (
) ARE
IMPORTANT FOR MAINTAINING THE SAFETY
OF THE SET. BE SURE TO REPLACE THESE
PARTS WITH SPECIFIED ONES FOR MAINTAIN-
ING THE SAFETY AND PERFORMANCE OF THE
SET.
CAUTION
This circuit diagram is original one, therefore there may be light difference
from yours.
Содержание 70GS-61SC