32U-S610
10
Sub-Color Adjustment
1. Receive a good local channel.
2. Make sure the customer color control is set to center
position .
3. Enter the service mode and select service adjustment
"V03".
4. Adjust "V03" data value to obtain normal color level.
Brightness Adjustment
1. Receive a good local channel.
2. Make sure the customer brightness control is set to
center position.
3. Enter the service mode and select the service
adjustment "V05".
4. Adjust "V05" data value to obtain normal brightness
level.
5. For component input, enter the service mode and
select the service adjustment "V45".
6. Adjust "V45"data value to obtain normal contrast
range.
Vertical-Size and Linearity Adjustments
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "D03" for V-size.
3. Adjust the "D03" bus data to get the proper V-size.
4. For V-linearity adjustment, select data bus "D05" and
adjust to get the proper vertical linearity.
Note: Aging for 10 min before adjustment. After the
adjustment of V-center and V-size, re-
adjustment for this V-line.
Vertical Phase Adjustment
1. Enter the service mode and select the service
adjustment "D01".
2. Adjust "D01" data value so that picture is centered.
Horizontal Position Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "D02".
3. Adjust "D02" data value so that picture is centered.
Caption Position Adjustment (Horizontal)
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "EX2".
3. A black text box appears on the screen. (see
Figure
B. below)
4. Adjust "EX2" data value so that text box is positioned
in the center of the screen.
Horizontal-Size Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "D04" for H-size.
3. Adjust the "D04" bus data to get the proper H-size.
EW-Parabola
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "D07" for EW parabola.
3. Adjust the "D07" bus data to get the proper vertical
straight line for both left and right side.
EW-Trapezium
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "D08" for EW-Trapezium.
3. Adjust the "D08" bus data to get the best position
display.
Содержание 32U-S610
Страница 13: ...32U S610 6 5 4 3 2 1 A B C D E F G H 13 CHASSIS LAYOUT ...
Страница 14: ...32U S610 6 5 4 3 2 1 A B C D E F G H 14 BLOCK DIAGRAM ...
Страница 16: ...17 32US610 16 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H ...
Страница 17: ...19 32US610 18 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H ...
Страница 18: ...32U S610 6 5 4 3 2 1 A B C D E F G H 20 SCHEMATIC DIAGRAM CRT Unit ...
Страница 19: ...22 32US610 21 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H ...
Страница 20: ...32U S610 24 23 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM P IN P Unit ...
Страница 21: ...32U S610 6 5 4 3 2 1 A B C D E F G H 25 SCHEMATIC DIAGRAM MTS MODULE Unit ...
Страница 22: ...32U S610 6 5 4 3 2 1 A B C D E F G H 26 PRINTED WIRING BOARD ASSEMBLIES PWB A MAIN Unit Wiring Side ...
Страница 23: ...32U S610 6 5 4 3 2 1 A B C D E F G H 27 PWB A MAIN Unit Chip Parts Side ...
Страница 24: ...32U S610 6 5 4 3 2 1 A B C D E F G H 28 PRINTED WIRING BOARD ASSEMBLIES PWB B CRT Unit Wiring Side ...
Страница 25: ...32U S610 6 5 4 3 2 1 A B C D E F G H 29 PWB C AV Unit Wiring Side PWB C AV Unit Chip Parts Side ...
Страница 26: ...32U S610 6 5 4 3 2 1 A B C D E F G H 30 PWB R P IN P Unit Wiring Side PWB R P IN P Unit Chip Parts Side ...