![Sharp 27U-F500 Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/sharp/27u-f500/27u-f500_service-manual_373579012.webp)
12
27U-F500
27U-F810
Ë
P-IN-P ADJUSTMENT
(Only for 27U-F810)
Ë
MTS ADJUSTMENT
MTS Level Adjustment
1. Set the sound volume above 1.
Monoral signal: 400Hz, 100% modulation
2. Confirm "M01" data is "09h".
3. Vary the "EX4" bus data until the voltage to pin (39)
of IC3001.
4. Become the value as stated below.
Only for 27U-F810
1. Set the sound volume above 1.
2. Vary the "M06" bus data until the voltage to pin (39)
of IC3001.
3. Becomes the value as stated below.
SETTING VOLTAGE
ADJ spec : 490±10mVrms
CHK spec: 490±20mVrms
MTS VCO Adjustment
1. Keep the unit in no-signal state.
2. Connect the frequency counter to pin (39) of IC3001.
3. Connect a capacitor (100µF, 50V) in between
po) side of C3005 and ground.
4. Enter the service mode and select the service
adjustment "M02"
5. Adjust the data so that the frequency counter reads
62.94 ±0.75kHz.
Filter Adjustment
1. Feed the following stereo pilot signal to pin (14) of
IC3001 .
Stereo pilot signal: 9.4kHz, 600mVrms.
2. Enter the service mode and select the service
adjustment "M03".
3. Adjust the data until "OK" appears in position on the
screen. Make sure the "OK" is displayed almost at
the center of the data range.
Separation Adjustment
1. Input "SIGNAL 1" and vary the "M04" bus data to get
the minimun AC voltage to pin (39) of IC3001.
2. Input "SIGNAL 2" and vary the "M05" bus data to get
the minimun AC voltage to pin (39) of IC3001.
SIGNAL 1: 300Hz, 30% modulation, Lch only, NR-ON
SIGNAL 2: 3kHz, 30% modulation, Lch only, NR-ON
•
Only for 27U-F810
1. Input "SIGNAL 1" and vary the "M07" bus data to get
the minimun AC voltage to pin (39) of IC3001.
2. Input "SIGNAL 2" and very the "M08" bus data to get
the minimun AC voltage to pin (39) of IC3001.
Note: SIGNAL 1 Adj. for widebando
SIGNAL 2 Adj. for spectral
Check the output of the speaker at the maximum
volume as stated below.
Confirmation spec:
ADJ spec: above 25 dB
CHK spec: above 20 dB
P-IN-P Y-LEVEL Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "P01".
3. Adjust "P01" data value to obtain normal contrast
level.
P-IN-P TINT Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "P02".
3. Adjust data value to "29".
P-IN-P COLOR Adjustment
1. Receive a good local channel.
2. Make sure the customer color control is set to center
position.
3. Enter the service mode and select the service
adjustment "P03".
4. Adjust "P03" data value to obtain normal color level.
P-IN-P Y-OFF SET Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "P04".
3. Adjust data value to "09".
P-IN-P H-POSITION Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "P05".
3. Adjust data value to "0A".
P-IN-P BURST GATE PULSE (for MAIN)
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "P06".
3. Adjust data value to "00".
P-IN-P FREERUN
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "P07".
3. Adjust data value to "0B".
P-IN-P TINT INPUT Adjustment
1. Receive an AV/Component input signal.
2. Enter the service mode and select the service
adjustment "P08".
3. Adjust data value to "24".
Содержание 27U-F500
Страница 13: ...13 27U F500 27U F810 6 5 4 3 2 1 A B C D E F G H MODEL 27U F500 CHASSIS LAYOUT ...
Страница 14: ...14 27U F500 27U F810 6 5 4 3 2 1 A B C D E F G H MODEL 27U F810 CHASSIS LAYOUT ...
Страница 15: ...15 27U F500 27U F810 6 5 4 3 2 1 A B C D E F G H MODEL 27U F500 BLOCK DIAGRAM ...
Страница 16: ...16 27U F500 27U F810 6 5 4 3 2 1 A B C D E F G H MODEL 27U F810 BLOCK DIAGRAM ...
Страница 18: ...18 27U F500 27U F810 8 7 10 9 6 5 4 3 2 1 A B C D E F G H MODEL 27U F500 SCHEMATIC DIAGRAM MAIN 1 Unit ...
Страница 19: ...19 27U F500 27U F810 17 16 19 18 15 14 13 12 11 10 ...
Страница 20: ...20 27U F500 27U F810 8 7 10 9 6 5 4 3 2 1 A B C D E F G H MODEL 27U F500 SCHEMATIC DIAGRAM MAIN 2 Unit ...
Страница 21: ...21 27U F500 27U F810 17 16 19 18 15 14 13 12 11 10 ...
Страница 22: ...22 27U F500 27U F810 8 7 10 9 6 5 4 3 2 1 A B C D E F G H MODEL 27U F810 SCHEMATIC DIAGRAM MAIN 1 Unit ...
Страница 23: ...23 27U F500 27U F810 17 16 19 18 15 14 13 12 11 10 ...
Страница 24: ...24 27U F500 27U F810 8 7 10 9 6 5 4 3 2 1 A B C D E F G H MODEL 27U F810 SCHEMATIC DIAGRAM MAIN 2 Unit ...
Страница 25: ...25 27U F500 27U F810 17 16 19 18 15 14 13 12 11 10 ...
Страница 26: ...26 27U F500 27U F810 8 7 10 9 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM AV Unit ...
Страница 27: ...27 27U F500 27U F810 17 16 19 18 15 14 13 12 11 10 ...
Страница 28: ...28 27U F500 27U F810 8 7 10 9 6 5 4 3 2 1 A B C D E F G H MODEL 27U F500 SCHEMATIC DIAGRAM MTS MODULE Unit ...
Страница 29: ...29 27U F500 27U F810 17 16 19 18 15 14 13 12 11 10 ...
Страница 30: ...30 27U F500 27U F810 8 7 10 9 6 5 4 3 2 1 A B C D E F G H MODEL 27U F810 SCHEMATIC DIAGRAM MTS MODULE Unit ...
Страница 31: ...31 27U F500 27U F810 17 16 19 18 15 14 13 12 11 10 ...
Страница 32: ...32 27U F500 27U F810 8 7 10 9 6 5 4 3 2 1 A B C D E F G H MODEL 27U F810 SCHEMATIC DIAGRAM P IN P Unit ...
Страница 33: ...33 27U F500 27U F810 17 16 19 18 15 14 13 12 11 10 ...
Страница 34: ...34 27U F500 27U F810 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM CRT Unit ...
Страница 35: ...35 27U F500 27U F810 6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM DF MODULE Unit ...
Страница 36: ...36 27U F500 27U F810 6 5 4 3 2 1 A B C D E F G H MODEL 27U F810 SCHEMATIC DIAGRAM 2 TUNER Unit ...
Страница 38: ...38 27U F500 27U F810 6 5 4 3 2 1 A B C D E F G H PWB A MAIN Unit Wiring Side ...
Страница 39: ...39 27U F500 27U F810 6 5 4 3 2 1 A B C D E F G H PWB A MAIN Unit Chip Parts Side ...
Страница 40: ...40 27U F500 27U F810 6 5 4 3 2 1 A B C D E F G H PWB C AV Unit Chip Parts Side PWB C AV Unit Wiring Side ...