CIRCUIT PROTECTION
The receiver is protected by a 3.15A fuse (F701),
mounted on PWB-A, wired into one side of the AC
line input.
X-RADIATION PROTECTOR CIRCUIT TEST
After service has been performed on the horizontal
deflection system, high voltage system, B+ system,
test the X-Radiation protection circuit to ascertain
proper operation as follows:
1. Apply 110~220V AC using a variac transformer for
accurate input voltage.
2. Allow for warm up and adjust all customer controls
for normal picture and sound.
3. Receive a good local channel.
4. Connect a digital voltmeter to P603 pin3 and make
sure that the voltmeter reads 20
±
1.1V.
5. Apply external 27V DC at P603 pin3 by using an
external DC supply, TV must be shut off.
6. To reset the protector, unplug the AC cord and make
a short circuit between P603 pin1 and P603 pin2.
Now make sure that normal picture appears on the
screen.
7. If the operation of the horizontal oscillator does not
stop in step 5, the circuit must be repaired before the
set is returned to the customer.
HIGH VOLTAGE CHECK
High voltage is not adjustable but must be checked
to verify that the receiver is operating within safe
and efficient design limitations as specified checks
should be as follows:
1. Connect an accurate high voltage meter between
ground and anode of picture tube.
2. Operate receiver for at least 15 minutes at 110~220V
AC line voltage, with a strong air signal or a properly
tuned in test signal.
3. Enter the service mode and set Y-mute ON by using
Service R/C.
4. The voltage should be approximately 28.7kV (at zero
beam).
If a correct reading cannot be obtained, check circuitry
for malfunctioning components. After the voltage test,
make Y-mute off to the normal mode.
INSTALLATION AND SERVICE INSTRUCTIONS
Note:
(1) When performing any adjustments to resistor controls and transformers use non-metallic
screwdrivers or TV alignment tools.
(2) Before performing adjustments, the TV set must be on at least 15 minutes.
21FL84
5
Содержание 21FL84
Страница 15: ...6 5 4 3 2 1 A B C D E F G H CHASSIS LAYOUT 21FL84 15 ...
Страница 16: ...A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 MAIN BLOCK DIAGRAM 21FL84 16 ...
Страница 17: ...10 11 12 13 14 15 16 17 18 19 21FL84 17 ...
Страница 18: ...6 5 4 3 2 1 A B C D E F G H CRT BLOCK DIAGRAM 21FL84 18 ...
Страница 20: ...A B C D E F G H 10 9 8 7 6 5 4 3 2 1 SCHEMATIC DIAGRAM MAIN 1 Unit 21FL84 20 ...
Страница 21: ...17 16 19 18 15 14 13 12 11 10 21FL84 21 ...
Страница 22: ...6 5 4 3 2 1 A B C D E F G H SCHEMATIC DIAGRAM CRT Unit 21FL84 22 ...
Страница 23: ...6 5 4 3 2 1 A B C D E F G H PWB A MAIN Unit Wiring Side PRINTED WIRING BOARD ASSEMBLIES 21FL84 23 ...
Страница 25: ...6 5 4 3 2 1 A B C D E F G H PWB B CRT Unit Wiring Side 21FL84 25 ...
Страница 31: ...PACKING OF THE SET 21FL84 21FL84 31 ...
Страница 32: ... M E M O 21FL84 32 ...