16
www.sharkclean.eu
CHECKING FOR BLOCKAGES
Blockages may cause your vacuum to overheat and shut
down. To prevent this from happening, check potential
blockage areas after heavy use or if you detect a loss of
suction or poor cleaning performance.
1
Dust Cup
Dust cup may be full. Empty dust cup.
2
Pre-Motor & Post-Motor Filters
• Pre-motor filters require washing every 3 months
for optimum performance.
The post-motor HEPA filter needs to be washed
every 2 years.
• Ensure that all the filters are clean.
3
Accessories
• Check intake openings:
- Extension Wand
- Dusting Brush
- Crevice Tool
- Car Detail Tool
4
Hose and Connections to Vacuum
• Detach the stretch hose from the back of the
portable
Lift-Away
®
canister by squeezing the tabs
together and pulling up.
(Fig. 27)
Straighten out
the hose and look inside for blockages.
• Remove the dust cup and extension wand and
separate the portable
Lift-Away
canister from the
motorised floor brush. Look in all 4 openings for
any blockages.
(Fig. 28)
5
Motorised Floor Brush
• Detach the hose on the motorised floor brush
at the top by squeezing the tabs together and
pulling out, and at the bottom by pulling out the
connector. Inspect inside the 3 holes.
(Fig. 29)
Fig. 27
Fig. 29
Fig. 28
CAUTION:
Turn power off and unplug from outlet before servicing.