SANDBLAST SYSTEM
OPERATOR’S MANUAL
9
Shark Sandblast System
•
97-612 • Rev. 3/06
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSES
SOLUTION
NO SAND BEING
DRAWN INTO SYSTEM
Plugged sand pot, probe or hose
Remove obstruction.
Wet sand
Use only dry sand.
Plugged spray nozzle
Remove nozzle with 9/16" socket and clean.
Air leaks at hose connection
Keep connections tight and in good repair.
Valve on wand open
Close valve.
Cone or probe closed
Turn cone to open position.
Sand probe not imbedded in sand
Keep probe in sand.
LOW SAND FLOW
Low water pressure
Check pump and nozzle for improper operation.
Collapsed hose
Replace hose or remove obstruction.
Clogged hose or probe
Clear obstruction.
Air leaks at hose connections
Keep connection tight.