User manual
1.Function
The LED floodlight LED‘s LIGHT PRO series directly opera-
ted with 230V AC power multi-chip LED luminous flux pro-
vides depending on the color of light and power class of 825
lm - 6,270 lm. Due to the elimination of the ballast could be
a small compact design achieved.
Features and functions:
– Bright light with 3000K or 5700K (depending on type)
– Weatherproof and robust powder-coated die-cast alu-
minum housing IP65
– Protection class II (no earth connection)
– Operating at 230 V
2. Operation, maintenance and safety
Please read this manual before installing and commissio-
ning complete and keep the Manual
for later use. If you leave the device to other persons for
use, pass them these instructions.
Safety and use instructions
Please note!
LED-risk group 1 according to EN 62471: 2008
Work on the 230 V mains are only to trained persons or qua-
lified electricians allowed. If you are not entitled to do this
work, hire a qualified electrician.
– Connection to the 230 V mains must made professional,
e.g. via an installation box with fixed screw terminals.
– The luminaire complies with protection class II and the-
refore not have the protective conductor connected.
– The lamp must be installed so that no accumulation of
heat, such as a cover, can happen.
– The lamp is not dimmable.
– The luminaire is designed for outdoor use. Cannot be
used in explosive or fire-prone areas.
– Keep the lamp away from flammable materials and ar-
ticles!
– For all kinds of damage, especially on the housing, which
no longer permit safe operation of the lamp is immedia-
tely to turn off the power supply voltage free to put the
light out of service and secured against re-start!
– The light is not allowed be altered or modified.
– In commercial institutions, the accident prevention regu-
lations of the professional associations should be obser-
ved for electrical systems and equipment.
– Repairs may only be carried out by a specialist, and using
only original spare parts.
To property or personal injury caused by improper use or not
following the safety, we do not assume any liability. In such
cases any warranty claim expires!
For further damages we do not assume any liability!
3. Mounting
– Turn off the power supply for the floodlight all-pole vol-
tage-free, determine the voltage, and protect the power
supply against reconnection.
– Loosen the side screws that connect the bracket to the
luminaire and then remove the bracket from.
– Draw by using the mounting bracket, the mounting holes
on the mounting place.
– Mount, depending on the type of wall by drilling in wood
or using dowels with stone walls, the mounting bracket.
– Screw the luminaire to the mounting bracket using the
two previously released, side screws.
– Connect the connection cable of the luminaire with the
terminals of the wall connection box (not included) and
close it properly to ensure protection. Here, make sure
that the cable inlets complete sealing, any existing co-
ver gaskets are installed correctly and no cables are
pinched.
– If everything checked and is ok turn on the line volta-
ge to test the function and/or for normal use of the LED
spotlight.
4. Warning
In operation, do not look into the light!
Risk of injury to the eyes!
Care and warranty
Before cleaning the unit, disconnect it if necessary from
other components; do not use aggressive cleaning agents.
The unit has been carefully checked for defects. If never-
theless you do have cause for complaint, please go back
to the retailer where you have bought the product together
with your proof of purchase. We offer a 2 year warranty
from date of purchase. We are not liable for damage arising
from incorrect handling, improper use or wear and tear. We
reserve the right to make technical modifications.
Visit us online at www.shada.nl for more information about
our products and our company