TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSE

ACTION

JACK WILL NOT LIFT TO FULL 
HEIGHT

LOW OIL LEVEL

CHECK OIL LEVEL AND REFILL IF 
NECESSARY

JACK WILL NOT HOLD LOAD

RELEASE VALVE NOT CLOSING
OIL CONTAMINATED
PUMP VALVES NOT SEALING
CYLINDER RAM BINDING

CONTACT CUSTOMER SERVICE

LIFT ARM WILL NOT LOWER

CYLINDER RAM BINDING
PARTS WORN
INTERNAL DAMAGE
BROKEN RETURN SPRING
LIFT ARM LINKAGE BENT OR 
BINDING

CONTACT CUSTOMER SERVICE

JACK FEELS SPONGY WHEN 
LIFTING

SEE AIR PURGE SECTION

PURGE TRAPPED AIR

FACTORY SERVICE

If this hydraulic jack if found to be damaged in any way, worn or oper-

ating abnormally it should be removed from service until inspected by 

an authorised repair centre.

Owner/operators should be aware that the repair of this jack requires 

specialised equipment and knowledge. Only factory authorised parts, 

labels and decals shall be used on this equipment. An annual inspec-

tion of this jack by an authorised repair centre is recommended to 

ensure the jack maintains an optimum operating condition.

WWW.SGS-ENGINEERING.COM

Содержание TJ2C

Страница 1: ...FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE OWNER S MANUAL TJ2C TROLLEY JACK 2 TON MAX CAPACITY...

Страница 2: ...is jack The owner operator shall retain these product instructions for future reference This jack shall be maintained in accordance with the product instructions No alterations shall be made to this j...

Страница 3: ...manual to ascertain the location of jacking points and position the jack beneath the lift point 4 Turn the release valve clockwise to the closed position but do not over tighten 5 To raise the vehicle...

Страница 4: ...tion to all moving parts as needed Every 6 months Carry out a thorough inspection for service ability of component parts Visually inspect for oil leaks only a slight oil seepage is permissible If a le...

Страница 5: ...n 6 Purge air from the system as required SYSTEM AIR PURGE 1 Turn the release valve counter clockwise one full turn to open 2 Pump the handle eight full strokes 3 Turn release valve clockwise to close...

Страница 6: ...MER SERVICE JACK FEELS SPONGY WHEN LIFTING SEE AIR PURGE SECTION PURGE TRAPPED AIR FACTORY SERVICE If this hydraulic jack if found to be damaged in any way worn or oper ating abnormally it should be r...

Страница 7: ...n damage to the jack and or failure resulting in personal injury or property damage Inspect the jack before each use WARRANTY This SGS product is covered by a 24 month warranty from the initial date o...

Страница 8: ...Secretary Derby UK 24th JUNE 2017 SGS Engineering UK Ltd SGS Engineering UK Ltd West Side Park Raynesway Derby DE21 7AZ Hydraulic Trolley Jack TJ2C 2006 42 EC Machinery Directive as amended by direct...

Отзывы: