STARTING THE ENGINE

6.  Pull the recoil starter grip lightly until-resistance is felt, then 

pull it briskly. Do not allow the recoil starter grip to snap back 
against the engine. Return it gently to prevent damage to the 
starter.

7.   If the choke lever was moved to the CLOSED position to start 

the engine, gradually move it to the OPEN position as the en-
gine warms up.

SETTING THE ENGINE SPEED

8.  After starting the engine, move the throttle lever to the FAST 

position for self-priming, and check pump output. Pump output 
is controlled by adjusting engine speed. Moving the throttle 
lever in the FAST direction will increase pump output, and mov-
ing the throttle lever in the SLOW direction will decrease pump 
output.

9.   To stop the engine in an emergency, simply turn the ignition 

switch to the OFF position. Under normal conditions, use the 
following procedure.

 

a.   Move the throttle lever to the SLOW position.

 

b.   Turn the ignition switch to the OFF position.

 

c.   Turn the fuel valve lever to the OFF position.

      After use, remove the pump drain plug, and drain the pump 

chamber. Remove the filler cap, and flush the pump chamber 
with clean, fresh water. Allow the water to drain from the pump 
chamber, then re-install the filler cap and drain plug.

WWW.SGS-ENGINEERING.COM

Содержание SWPT80

Страница 1: ...FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE OWNER S MANUAL SWPT80 PETROL TRASH WATER PUMP...

Страница 2: ...other solids from being drawn up which could cause severe damage to the pump 4 ALWAYS keep the machine itself dry and well clear of water discharge 5 ALWAYS use only replacement parts supplied by the...

Страница 3: ...place the dipstick filler cap NOTE The unit is fitted with a low oil sensor which will stop the engine if the oil level drops below the safe level to avoid internal damage Refer to troubleshooting sec...

Страница 4: ...engine move the choke lever to the CLOSED position To restart a warm engine leave the choke lever in the OPEN position STARTING THE ENGINE 4 Move the throttle lever away from the SLOW position about...

Страница 5: ...controlled by adjusting engine speed Moving the throttle lever in the FAST direction will increase pump output and mov ing the throttle lever in the SLOW direction will decrease pump output 9 To stop...

Страница 6: ...water Instantaneous shut off pressure applied when a vehicle runs across an unprotected hose will cause hydraulic shock which can dam age the pump and or the hose GENERAL USE OF THE PUMP 3 Attach the...

Страница 7: ...t to your local waste disposal site STORAGE HANDLING After use drain the pump body whenever there is danger of free ing and if the pump has been used with contaminated or salty water It should be thor...

Страница 8: ...epairs as necessary check repair connections as required Blocked inlet hose Clean strainer ensure it is not submerged in mud or sediment etc Ensure there are no kinks in delivery hose Engine speed too...

Страница 9: ...user 1 902334 8 Impeller 1 902303 9 Spring column pin 2 902335 10 O Ring 125 x 2 65 1 902336 11 O Ring 260 x 5 1 902337 12 Pump cover 1 902338 13 Mechanical seal 1 902339 14 Hexangular hose joint 1 90...

Страница 10: ...munities Directive s and Standard s PLACE DATE Signature Robert Wyatt Company Secretary Derby UK 24th MAY 2018 SGS Engineering UK Ltd SGS Engineering UK Ltd West Side Park Raynesway Derby DE21 7AZ Wat...