PAGE 5
PAGE 4
BEFORE USE
Operating the pump dry will destroy the pump
seal. If the pump has been operated dry, stop the
engine immediately, and allow the pump to cool
before priming
This pump is not supplied with engine oil or fuel. Use any engine
oil of SAE 10-30 rating unless operating at very high or low ambi-
ent temperatures.
1. Remove the filler plug/dipstick.
2. Fill the unit with oil until visible inside.
3. Check the level by inserting the dipstick
back into the filler tube and checking the
level is within the indicated range. If cor-
rect replace the dipstick/filler cap.
NOTE: The unit is fitted with a low oil sensor which will stop the
engine if the oil level drops below the safe level to avoid internal
damage. Refer to troubleshooting section.
ADDING FUEL
Fill the fuel tank with unleaded petrol or check the level by open-
ing the fuel cap and topping up as required. Located within the
fuel tank is a strainer. Check this filter periodically and remove any
contaminants which may have accumulated. Do not fill above the
fuel strainer shoulder. After refuelling, tighten the fuel filler
cap securely. Use unleaded petrol with a pump octane rating
of 86 or higher.
WARNING: WIPE UP ANY SPILT FUEL BEFORE
RUNNING THE PUMP. ALLOW THE ENGINE TO
COOL DOWN BEFORE REFUELLING
WWW.SGS-ENGINEERING.COM