background image

PAGE 11

PAGE 10

TROUBLESHOOTING

SERVICE AND REPAIRS

All quality tools will eventually require servicing or replacement of parts due to wear 
from normal use. These operations should ONLY be performed by a licensed profes-
sional technician. Never try to repair the tool by yourself.

Disconnect tool from air supply before performing any 
service procedure.

 

 WARNING   

SYMPTOM

PROBLEM

SOLUTION

Air leak near top 
of tool or in trigger 
area.

Loose screws.
Worn or damaged o-rings 
or seals.

Tighten screws.
Install overhaul kit.

Tool does nothing 
or operates 
sluggishly.

Inadequate air supply.
Inadequate lubrication.
Worn or damaged O-rings 
or seals.

Verify screws.

Install overhaul kit.

Air leak near 
bottom of tool.

Loose screws.
Worn or damaged O-rings or 
bumper.

Tighten screws.
Install overhaul kit.

Tool jams 
frequently.

Incorrect fasteners.
Damaged fasteners.
Magazine or nose screw 
loose.
Magazine is dirty.
Driver is worn or damaged.

Verify fasteners of correct size.
Replace fasteners.
Tighten screws.

Clean screws.
Install Driver maintenance kit.

Other

Contact SGS Engineering.

WWW.SGS-ENGINEERING.COM

Содержание SAT403

Страница 1: ...FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE OWNER S MANUAL SAT403 BRAD NAILER STAPLER ...

Страница 2: ...nal injury could result 6 Wear ear protection to safe guard against possible hearing loss 7 Use clean dry regulated compressed air at 75 to 100 PSI 8 Only use air hose that is rated for a maximum working pressure of at least 150 PSI or 150 of the maximum system pressure which ever is greater 9 Disconnect tool from air supply hose before performing tool mainte nance clearing a jammed fastener leavi...

Страница 3: ...cle occurs WARNING CHECK AND REPLACE ANY DAMAGED OR WORN COMPONENTS SAFETY WARN ING LABELS ON THE TOOL MUST ALSO BE REPLACED IF THEY ARE NOT LEGIBLE LOADING THE TOOL Connect the air hose Depress the magazine latch Pull back on the magazine cover Insert a stick of fasteners into the magazine Make sure the pointed ends of the fasteners are loaded with the points downward Also make sure fasten ers ar...

Страница 4: ... of the tool A filter also increase the efficiency and lifespan of the tool The filter must be checked on a daily basis and if necessary drained CORRECT CONNECTION OF THE TOOL CLEARING A JAM FROM THE TOOL FASTENER JAMMED IN FASTENER DISCHARGE AREA Disconnect air tool from air hose Open the nozzle part grab jammed fastener with pliers and remove FASTENER JAM INSIDE MAGAZINE Disconnect air tool from...

Страница 5: ...PAGE 9 PAGE 8 PARTS LIST PARTS DIAGRAM WWW SGS ENGINEERING COM ...

Страница 6: ...crews Worn or damaged o rings or seals Tighten screws Install overhaul kit Tool does nothing or operates sluggishly Inadequate air supply Inadequate lubrication Worn or damaged O rings or seals Verify screws Install overhaul kit Air leak near bottom of tool Loose screws Worn or damaged O rings or bumper Tighten screws Install overhaul kit Tool jams frequently Incorrect fasteners Damaged fasteners ...

Страница 7: ...URING AND CONTINUAL IMPROVEMENT OUR REGISTRATION VERIFIES THAT SGS ENGINEERING HAS ADOPTED AND MAINTAINS DOCUMENTATION FOR PROCESSES RANGING FROM SUPPLIERS TO CUSTOMERS INSPECTION HANDLING AND TRAINING ISO 9001 ALSO REQUIRES PERIODIC INTERNAL AND EXTERNAL AUDITS TO ENSURE ALL ASPECTS OF WORK AFFECTING QUALITY CONTROL ARE MONITORED THIS ALWAYS HAS BEEN AND WILL CONTINUE TO BE OUR PHILOSOPHY THAT S ...

Отзывы: