SGS Breeze 320 Скачать руководство пользователя страница 5

 

ELECTRICAL

 

HAZARD

 

 

All

 

Breeze

 

systems

 

are

 

shipped

 

from

 

the

 

factory

 

wired

 

for

 

220

 

Volts.

 

 

To

 

reduce

 

risk

 

of

 

electrical

 

shock

 

make

 

sure

 

all

 

power

 

to

 

pool

 

equipment

 

area

 

is

 

off

 

prior

 

to

 

any

 

installation

 

or

 

removal

 

of

 

Breeze

 

System

 

components.

 

 

Immediately

 

replace

 

damaged

 

Control

 

Center

 

cord.

  

 

Do

 

not

 

bury

 

cord.

  

Locate

 

cord

 

to

 

minimize

 

abuse

 

from

 

lawn

 

mowers,

 

hedge

 

trimmers

 

and

 

other

 

equipment.

 

 

Severe

 

shock

 

or

 

injury

 

will

 

likely

 

occur

 

as

 

a

 

result

 

of

 

drill

 

or

 

drill

 

cord

 

coming

 

in

 

contact

 

with

 

water.

  

Never

 

allow

 

electric

 

drill

 

or

 

cord

 

to

 

come

 

in

 

contact

 

with

 

water.

  

Only

 

plug

 

drill

 

into

 

a

 

Class

 

A

 

(5

 

Millampere

 

Trip)

 

protected

 

Ground

 

Fault

 

Circuit

 

Interrupter

 

(GFCI)

 

in

 

accordance

 

with

 

the

 

National

 

Electrical

 

Code

 

Section

 

680

 

(USA

 

ONLY).

  

Please

 

see

 

your

 

drill

 

owner’s

 

manual

 

for

 

further

 

safety

 

precautions.

 

 

Install

 

the

 

Control

 

Center

 

at

 

least

 

10

 

feet

 

from

 

the

 

inside

 

walls

 

of

 

a

 

pool

 

to

 

prevent

 

any

 

possibility

 

of

 

the

 

unit

 

coming

 

in

 

contact

 

w

i

th

 

water.

 

 

The

 

Breeze

 

Chlorinator

 

has

 

been

 

designed

 

with

 

an

 

internal

 

electronic

 

flow

 

sensing

 

tab.

  

This

 

device

 

automatically

 

switches

 

the

 

power

 

to

 

the

 

electrolytic

 

cell

 

“OFF”

 

when

 

the

 

water

 

through

 

the

 

cell

 

stops.

  

To

 

prevent

 

cell

 

damage

 

and/or

 

personal

 

injury,

 

do

 

not

 

in

 

any

 

way

 

interfere

 

with

 

this

 

system

 

which

 

has

 

been

 

designed

 

for

 

your

 

protection.

 

 
 

CHEMICAL

 

USE

 

HAZARD

 

 

To

 

avoid

 

personal

 

injury

 

when

 

working

 

with

 

pool

 

chemicals,

 

always

 

wear

 

rubber

 

gloves

 

and

 

eye

 

protection,

 

and

 

work

 

in

 

a

 

well

ventilated

 

area.

  

Use

 

caution

 

when

 

choosing

 

a

 

location

 

to

 

open

 

and

 

use

 

chemicals

 

as

 

they

 

may

 

damage

 

any

 

surface

 

to

 

which

 

they

 

come

 

in

 

contact.

 

 

The

 

addition

 

of

 

certain

 

chemicals

 

can

 

reduce

 

the

 

effectiveness

 

of

 

chlorine.

  

Always

 

make

 

sure

 

that

 

proper

 

residual

 

chlorine

 

levels

 

are

 

maintained

 

to

 

avoid

 

personal

 

injury.

 

 

This

 

product

 

produces

 

chlorine.

  

Individuals

 

with

 

any

 

type

 

of

 

chlorine

 

sensitivity

 

should

 

take

 

the

 

appropriate

 

precautions

 

to

 

avoid

 

injury

 

or

 

illness.

 

 
 
 

  

Important

 

Notice:

 

Attention

 

Installer:

 

This

 

manual

 

contains

 

important

 

information

 

about

 

the

 

installation,

 

operation

 

and

 

safe

 

use

 

of

 

this

 

product.

  

Before

 

installing

 

this

 

product,

 

read

 

and

 

follow

 

all

 

warning

 

notices

 

and

 

instructions

 

which

 

are

 

included.

   

This

 

information

 

should

 

be

 

given

 

to

 

the

 

owner

 

and/or

 

operator

 

of

 

this

 

equipment.

  

 

WARNING:

 

IMPORTANT

 

SAFETY

 

INSTRUCTIONS

 

PERTAINING

 

TO

 

RISK

 

OF

 

FIRE,

 

ELECTRIC

 

SHOCK,

 

OR

 

INJURY

 

TO

 

PERSONS.

  

READ

 

AND

 

FOLLOW

 

ALL

 

INSTRUCTIONS.

  

Failure

 

to

 

follow

 

safety

 

warnings

 

and

 

instructions

 

can

 

result

 

in

 

severe

 

injury,

 

death,

 

or

 

property

 

damage.

  

Call

 

1

866

972

SALT

 

or

 

go

 

to

 

www.sgshclorinators.com

 

for

 

additional

 

free

 

copies

 

of

 

these

 

instructions.

  

 

WARNING:

 

To

 

reduce

 

the

 

risk

 

of

 

injury,

 

installation

 

and

 

service

 

should

 

be

 

done

 

by

 

a

 

qualified

 

Pool

 

Service

 

Professional,

 

certified

 

electrician

 

or

 

authorized

 

SGS

 

representative.

 

5

 

 

Содержание Breeze 320

Страница 1: ...SG Owners Manual MODELS Breeze 320 Breeze 540 Breeze 760 Residential Systems...

Страница 2: ...ranty 6 Pool water must be tested regularly in order to properly maintain its chemical balance Problems or equipment failures resulting from the failure to maintain pool water chemistry in accordance...

Страница 3: ...Add It 9 Salt Table 10 Chlorinator Installation 11 Installation Preparation 12 Procedures for Installation 13 Special Situations 14 Start up procedures 14 System operation 15 Control Center Functions...

Страница 4: ...n if you cannot verify the receptacle is protected by a GFCI 4 Do not bury cord Locate cord to minimize abuse from lawn mowers hedge trimmers and other equipment 5 WARNING To reduce the risk of electr...

Страница 5: ...r protection CHEMICAL USE HAZARD To avoid personal injury when working with pool chemicals always wear rubber gloves and eye protection and work in a well ventilated area Use caution when choosing a l...

Страница 6: ...g or removing the Electrolytic cell Your pump filter is operated under pressure and the pressure must be released before you begin work Please see your pump filter owner s manual for further instructi...

Страница 7: ...portant aspect of maintaining a swimming pool Pool water must be tested regularly in order to properly maintain its chemical balance In accordance with The Association of Pool and Spas Professionals A...

Страница 8: ...til the reading taken at least 24 hours later is in the 80 100 PPM range When TA is correct you may need to adjust pH Use Chlorine Stabilizer to Protect Chlorine Residual Chlorine stabilizer also know...

Страница 9: ...dirty cell see illustration 5 on page 15 and Troubleshooting section for instructions on what to do when the system goes into service mode We recommend using pool salt which can be purchased at pool a...

Страница 10: ...293 330 367 403 440 477 513 550 587 523 660 697 733 2000 133 166 200 234 267 300 333 367 400 433 467 500 533 567 600 633 667 2200 120 150 180 210 240 270 300 330 360 390 420 450 480 510 540 570 600 24...

Страница 11: ...ing Bracket 1 Cleaning Stick Acid Replacement Device 1 Owner s Manual The following tools will be required to install the Breeze system Screwdriver Level Hacksaw or PVC cutter Wire Stripping Tool Elec...

Страница 12: ...if necessary can be reduced to 1 inch PVC The cell has a 15 foot power cord and cannot be modified use caution to place the cell housing within reach of the cell cord The Breeze Control Center is shi...

Страница 13: ...uitable location for the mounting of the Control Center The Control Center must be mounted on a noncombustible surface 2 The wall mounting bracket should be fastened to the wall at a height comfortabl...

Страница 14: ...d for cleaning when necessary START UP PROCEDURES 1 Balance your water chemistry according to the Water Chemistry Parameters shown on page 7 Add the proper amount of salt and circulate 24 hours before...

Страница 15: ...n the cell blades Chlorine production and scale buildup are easily visually monitored through the SG clear cell housing Control Center Functions 1 Sanitizer Output Lights shows level of chlorine outpu...

Страница 16: ...emely high bather load Unlike other chlorinators the Breeze is able to produce chlorine at all settings on the Sanitizer Output scale for the entire run time Adjusting the Output control from 75 down...

Страница 17: ...des and the legs that attach the electrodes to the cell base illustration 4 below If there is no buildup there is no need to clean the cell If there is buildup ALWAYS TURN OFF THE PUMP PRIOR TO CLEANI...

Страница 18: ...esh water A build up of byproducts can damage the electrolytic cell Monthly Service To ensure that the correct chemical balance is maintained in your pool it is important to perform the following reco...

Страница 19: ...ect the calcium hardness or total alkalinity levels Maintain and balance only as needed CYANURIC ACID STABILIZER CONDITIONER This chemical CYA or Cyanuric Acid allows your chlorine residual to last lo...

Страница 20: ...ight is yellow solid Increase Salt level by adding salt according to chart on Page 10 High nitrate level Contact Pool Professional Metals present in pool water Contact Pool Professional New pool water...

Страница 21: ...Part C on Illustration 2 page 13 on bottom of Control Center if tripped press rubber cover to reset No AC power to Control Center Verify time clock is providing 220 VAC to Control Center when active...

Страница 22: ...oot For Breaker 1 8 PC114 D2 10 Circuit Breaker 1 9 PC123 D 2 1 Control Center Label 1 10 PC133 D1 10 Primary Terminal Block 1 11 PC104 C3 2 Acrylic Cover 1 12 PC105 C3 5 On Off Switch 1 13 PK6101 D03...

Страница 23: ...evaluated for best results Where heightened chlorine demand exists due to warmer climates humidity high bather load water features and other environmental factors the maximum pool size should be reduc...

Страница 24: ...Date Control Center Serial Model Number Factory Direct Customer Assistance Tech Support Hotline 1 866 972 SALT 7258 or 1 480 385 3052 FAX 1 480 557 0099 Email to customersupport sgschlorinators com Re...